Laserfiche WebLink
SAN 4` " J O a Q U I N Environmental Health Department <br /> C 0 U 11-11 i `l <br /> Food Program Official Inspection Report <br /> Facility Name and Address: DAYS INN,4219 E WATERLOO RD, STOCKTON 95215 <br /> #21 Hot and Cold Potable Water Not Available <br /> OBSERVATIONS:The water at the bar 3 comp sink and hand sink reached 100 F but it was fluctuating depending on which <br /> sink was running. The water at the kitchen 2 comp sink was 121 F and stable. The water at the restroom hand sinks was 78 <br /> F. Provide consistent hot water at 120 F minimum at bar 3 comp sink and 100 F minimum at bar and restroom hand sinks. <br /> Correct immediately. <br /> CALCODE DESCRIPTION:An adequate,protected,pressurized,potable supply of hot water and cold water shall be provided at all times. <br /> (113953(c), 114099.2(b) 114101(a), 114189, 114192, 114192.1, 114195) <br /> #34 Warewashing Facilites Maintained <br /> OBSERVATIONS:Lacking chlorine test strips. Provide chlorine test strips within 1 week. <br /> CALCODE DESCRIPTION:Food facilities that prepare food shall be equipped with warewashing facilities. Testing equipment and <br /> materials shall be provided to measure the applicable sanitization method. (I14067(f,g), 114099, 114099.3, 114099.5, 114101(a), <br /> 114101.1, 114101.2, 114103, 114107, 114125) <br /> #35 Equipment/Utensils Approved and in Good Repair <br /> OBSERVATIONS:Observed leaking from 3 comp sink and right women's restroom hand sink faucet heads. Repair leaking <br /> within 1 week. <br /> Observed gap between bar hand sink and counter. Repair/replace within 2 weeks. <br /> CALCODE DESCRIPTION:All utensils and equipment shall be fully operative and in good repair. (114175).All utensils and equipment <br /> shall be approved,installed properly,and meet applicable standards. (114130, 114130.1, 114130.2, 114130.3, 114130.4, 114130.5, <br /> 114132, 114133, 114137, 114139, 114153, 114155, 114163, 114165, 114167, 114169, 114172, 114177, 114180, 114182) <br /> #39 Thermometers Provided/Accurate/Easily Visible <br /> OBSERVATIONS:The bar 5 dr reach-in did not have a thermometer. Provide thermometer within 1 week. <br /> CALCODE DESCRIPTION:An accurate easily readable metal probe thermometer suitable for measuring temperature of food shall be <br /> available to the food handler. A thermometer+/-2#F shall be provided for each hot and cold holding unit of potentially hazardous foods <br /> and high temperature warewashing machines. (114157, 114159) <br /> FA0002187 PRO161820 SC333 08/11/2022 <br /> EHD 16-23 Rev.09/16/2020 Page 2 of 4 Food Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />