My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0085076_OWTS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AHERN
>
29700
>
4200 – Liquid Waste Program
>
SR0085076_OWTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/30/2022 4:13:58 PM
Creation date
9/29/2022 9:09:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200 – Liquid Waste Program
FileName_PostFix
OWTS
RECORD_ID
SR0085076
PE
4201
FACILITY_NAME
AHERN TRUCK STOP
STREET_NUMBER
29700
Direction
S
STREET_NAME
AHERN
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
25502014
ENTERED_DATE
3/29/2022 12:00:00 AM
SITE_LOCATION
29700 S AHERN RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
207
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
10 <br /> Paul W. Donoho, R.E.H.S. #6227 <br /> (530) 701-9972 <br /> ° <br /> • - O&M <br /> COMMERCIAL <br /> About the AdvanTex <br /> Primary Tank Recirculation/Blend Tank <br /> The primary tank provides passive primary wastewater treatment.There The recirculation/blend tank reduces the strength of the effluent being <br /> can be one or more primary tanks in parallel or series,depending on applied to the AdvanTex filter.R is sized at So to 100%of the design flow. <br /> the size of the system.In certain applications,the primary tank may be It is located after the primary treatment tank and before the AdvanTex <br /> preceded by a grease interceptor tank. textile filter. <br /> The reduction in effluent strength is achieved by mixing treated filtrate <br /> from the AdvanTex filter with primary treated effluent at the recirc valve, <br /> located at the inlet of the recirculatioo/blend tank.A timer-controlled <br /> pump at the outlet end of the tank then sends the blended effluent to the <br /> AdvanTex filler. <br /> Seum AdvanTex®Textile Filter <br /> The AdvanTex textile filter pod provides secondary wastewater treatment. <br /> Clear There can be one or more AdvanTex pods,depending on the size of the <br /> system. <br /> The primary tank is an enclosed,watertight receptacle designed to <br /> collect wastewater;segregate settleable and floatable solids(sludge <br /> and scum);accumulate,consolidate,and store solids;digest organic <br /> matter;and discharge treated effluent.BUO(biochemical oxygen <br /> demand)removals of greater than 65%and TSS(total suspended <br /> solids)removals of greater than 70%are easily accomplished.In the <br /> primary tank,wastewater separates into three distinct layers:a floating <br /> The filter is a stur <br /> scum layer,a bottom sludge Payer,and a clear zone in between,which is sturdy,watertight fiberglass basin filled with an engineered <br /> relatively free of large solids.An eff€uent filter or pump vault allows liquid textile material.The textile media has a very large surface area and void <br /> effluent from the clear zone to be transported to the recirculation/blend volume(for free flow of oxygen).Wastewater percolates both through <br /> or recirculation/blend and anoxic tank. and between the textile media.A visible biological film normally develops <br /> on the filter media within a few days of system start-up.Within the filter, <br /> Anoxic Tank(if applicable) aembic conditions exist that are ideal for microbes that convert ammonia <br /> The anoxic(low oxygen)tank enhances the denitrification of AdvanTex® to nitrate(nitrification).BOD and TSS reductions occur almost immediately. <br /> filtrate.It is sized based on the design flow of the system.In systems that Nitrification may take four to six weeks,depending on ambient temperature. <br /> use an anoxic tank,ft is generally located between the primary tank,flow After percolating through the filter media,the effluent gravity-flaws to the <br /> splitter basin,and recirculation/blend tank in the treatment train. recirculating valve.On systems designed for enhanced nitrogen removal, <br /> The anoxic tank provides the ideal environment for carbonaceous the effluent first flows to a flow splitter basin where a percentage of the <br /> microbes that reduce nitrates to nitrogen gas(denitrification)from effluent is diverted to the inlet side of a primary tank or anoxic tank The <br /> AdvanTex filtrate returning from the flow splitter basin.The harmless remainder flows to the recirc valve,where It is directed either into the <br /> nitrogen gas is released freely back into the atmosphere, recirculation/blend tank or discharged. <br /> M1IN-ON-ATX ,Rev.2.1,05/15 •�Copyrighi Orenty Systems®,Inc•Pmperty of Orenco Systemsw,lnc�Do not raprotluee or di5tdbuie wpltout written authorization tram Orenco•800-348-9843 <br />