14 <br /> Paul W. Donoho, R.E.H.S. #6227 <br /> (530) 701-9972 <br /> AdvanTex@ O&M <br /> COMMERCIAL <br /> , Inspection ' • • - • <br /> 7.Panel operation:Verify that the panel is powered up. 4.Splice box.Inspect <br /> + On TCOM and VCDM panels,an LED will light up indicating the the splice box for <br /> board is operational.If the blinking light does not tum on,refer correct wiring and <br /> to the wiring diagram and verify the connections on the control the use of waterproof <br /> circuit were properly terminated. splice nuts.If there is <br /> water in the splice box, <br /> use a baster or sponge <br /> to remove the water. <br /> WARNING:Failure to use waterproof wire nuts can cause <br /> intermittent or permanent float failure, <br /> a: <br /> FC • 5.Effluent filter and float:Verify the effluent fitter cartridge and <br /> float assembly are easy to remove for service and maintenance. <br /> The ability to easily remove these components is essential and <br /> �'seo.roe �d s•sa• depends upon careful installation in accordance with the instructions <br /> Blinking LED- provided in Appendix B.Set components on a plastic tarp or plastic <br /> sheeting when they are out of the tank, <br /> • On MVP,Simplex,and Duplex panels,tum on the control circuit, a.Detach the float assembly from the housing,remove it from the <br /> then toggle the pump"AUTO-OFF-MAN"switch to"MAN."The tank,and lay it aside.Verify there is enough slack in the cord for <br /> motor contactor will visibly and audibly engage at this point.If easy removal. <br /> the motor contactor does not engage and there are no alarm <br /> conditions,refer to the wiring diagram and verify the connections b.Pull the effluent filter cartridge out of the housing,and remove <br /> on the control circuit were properly terminated. it from the tank_There Should be ample clearance to allow <br /> NOTE,ForVCOM-equipped systems,place VCDM in test mode unhindered removal of the cartridge from the housing and tank. <br /> at this point. c.Slide the filter housing out of the slide rail and remove the housing <br /> Inspection Points—Tanks and Basins from the tank.(Slide rail models only.) <br /> d.Raise the high-level alarm float to simulate a high-level condition. <br /> Not all tanks and basins have associated components as described below. Verify that the high-level signal is on by the audible alarm or the <br /> Check the system plans to Idenfrfy if there are associated components— high-level alarm input LED on the circuit board in the panel, <br /> such as splice boxes,floats,filters,or pump vaults—on each section of <br /> the system as you start it up. NOTE:The audible alarm is delayed for 2 hours in ICOM comrol <br /> 1.Tank:Confirm with the installer that all tanks have passed panels. <br /> watertightness testing.Verify the inlet and outlet of the tank and riser e.When the floats and filter cartridge are out of the tank,verily,the <br /> are properly installed. handles are long enough for easy access.If they are not,adjust <br /> 2.Basle:Verily the inlet and outlet of the basin are properly installed them to the necessary length, <br /> and the effluent flows through in the correct direction. f. Reinstall the cartridge into the effluent filter housing and install the <br /> 3.Riser:Inspect the riser attachment and rubber grommets for a float assembly. <br /> watertight seal. <br /> AIM-OM-ATX-9,Nev.�2,7,08!75 �•� Copyright OrCrlco Systems®,fn¢Property of orenco Sy5t0m5®,Inc.Do not reproduce or tllsirihute without written authonzatlat from ereoao:'8n0-348-9843 <br />