My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0085076_OWTS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AHERN
>
29700
>
4200 – Liquid Waste Program
>
SR0085076_OWTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/30/2022 4:13:58 PM
Creation date
9/29/2022 9:09:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200 – Liquid Waste Program
FileName_PostFix
OWTS
RECORD_ID
SR0085076
PE
4201
FACILITY_NAME
AHERN TRUCK STOP
STREET_NUMBER
29700
Direction
S
STREET_NAME
AHERN
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
25502014
ENTERED_DATE
3/29/2022 12:00:00 AM
SITE_LOCATION
29700 S AHERN RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
207
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
26 <br /> Paul W. Doli R.E.H.S. #6227 <br /> (530) 701-9972 <br /> AdvanTexO MANUAL• <br /> COMMERCIAL <br /> Maintenance • - s <br /> Corrective Maintenance e.Faufty floats—If,after checking the circuit breakers,fuses,and <br /> An alarm is triggered when the Aquid in the tank reaches a level that switches,the pump still does not operate,toggle the"AUTO- <br /> is either higher or tower than it should be,under normal operating OFF-MAN"switch to"MAN."If the pump engages,the problem <br /> Conditions. <br /> is likely to be in the float system.If the motor contactor engages <br /> but the pump doesn't run,go to step g,"Wafer in splice box or <br /> When responding to an alarm,first discern the type of alarm being loose wires.")Pump the tank down to a level below the"Override <br /> activated.If it is due to pump faifure,test each pump manually and locate Timer OrVOT float.Cycle the pump to simulate the timer on <br /> the tailed pump.To replace the pump,see the"Removing&Replacing and off periods so the effluent is dosed to different zones of <br /> Inoperative Pumps"section of this document.Remove the access riser lid the AdvanTex®system.Toggle the"AlfrO-OFF-MAN"switch to <br /> and visually inspect the liquid level.If a high liquid level or low liquid level "AUTO."Do not leave a pump in the"MAN"position unattended.If <br /> has caused the alarm,follow the appropriate procedures below you do,the pump can continue to operate without liquid,possibly <br /> drawing solids into the fifter and causing potential failures.Isolate <br /> High Liquid Leel Alarm the float switches and check to ensure all floats are operating <br /> 1.Determine if the high water alarm is from higher than expected properly.ff a float is found to be faulty,refer to the"Removing& <br /> usage(i.e.,special event,etc.).If there is a long-term increase in Replacing Inoperative Floats"section in this document. <br /> flows,then timer settings need to be adjusted accordingly. IMPORTANT!Before doling any work on either the wiring to <br /> 2.When a high liquid level condition exists,the source of the problem is the level control floats and pump or inside the pump control <br /> likely to be one of the following: panel,switch off the power to the system at the service <br /> entrance panel and set the circuit breakers in the panel to <br /> a.Poor valve seal—Consult the design plans for proper operating their'OFF"positions. <br /> level and visually inspectthe recirculating valve to verify the liquid d.Pump dooaed or not clean—Check the pump for discharge <br /> level in the tank is wfthin the normal range.If the liquid fevel is flow.Close the ball valve,disconnect the union in the discharge <br /> high,the valve may require cleaning because it is not making a <br /> fight seal when seated.Remove,disassemble,and inspect. plumbing assembly and tum the union so it is facing down. <br /> Engage the pump and visually inspect the approximate flow <br /> b.Control UgUel breakers tripped—Check the circuit breakers, rate being discharged.If you are unsure of the discharge rate, <br /> switches,and fuses in the system control panel.If separate measure the time it takes to fill a five-gallon bucket with the <br /> breakers in the main panel were used for the pumps and controls, discharge.Check this value against the appropriate pump curve. <br /> also check these breakers.If a breaker Is found to be tripped, If the flow rate is insufficient,the pump may need to be cleaned. <br /> reset the breaker.If the breaker trips immediately,check the Refer to the Pump Repair Manual provided In Appendix D. <br /> wiring for a short or bad breaker.If the breaker or breakers don't um e.Valves closed—If the <br /> trip again,then the problem has probably been found or has pump operas in the proper flow range, <br /> corrected itself.Test the automatic function of the system as check all downstream valves to ensure that they are in the open <br /> shown in the"Start-up&Operation"section of this manual to Position.If the valves are all open,test the discharge pressure of <br /> the pump.For proper pump testing methods,refer to the Pump <br /> verify proper operation. Repair provided in <br /> pa p Appendix D. <br /> AIM-DM-AM-3,Rr.e2.1,05/15 . <br /> ••copyright Orenco soterne,Inc.Property of 0renco systems®,rc.Do not repmducr;or tllstriwm wamt written autnurization from Drenco:800-348-8843, <br />
The URL can be used to link to this page
Your browser does not support the video tag.