Laserfiche WebLink
PROJECT: Ahern Road Fueling Station February 28, 2022 <br /> Job No : 20-544 Ross P . Shoaf, Civil Engineer <br /> SCHEMATIC LEACHFIELD LAYOUT — No Scale <br /> a <br /> One of 6 Fields Fed by Indexing Valve <br /> a, <br /> x <br /> FlushIno Assembly at End of Each Line Control Valve at Each Linedo <br /> 0 <br /> IC <br /> 1 � <br /> 10 <br /> 10 <br /> I 72 ' I <br /> All 6 Fields Will Have 5 Trenches for a Total of 30 trenches @ 72' = 2 ,160 ' total <br /> See Exhibit Sheets for Trench and <br /> Lateral Detail <br /> DETAILED DESIGN FOR LEACHFIELD LATERALS <br /> Manifold ( Header ) Pipe Size : 2" <br /> Lateral Pipe Size : 1 %" Total Number of Laterals : 30 <br /> Orifice Size : 1/8" Orifice Spacing : 48" Number of Orifices per lateral : 18 <br /> Total Number of Orifices 30 laterals X 18 Orifices = 540 <br /> Carson Boxes <br /> two oer Lateral <br /> I Orifice Shield Over Flushing <br /> .I - . � / Orifi a 4' s acin Valve <br /> Adjustm t <br /> Valve <br /> L�--- — <br /> Over all Trench Length 72' <br /> Schematic lateral layout <br /> No Scale <br /> Page 9 Of 11 <br />