My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
15346
>
1600 - Food Program
>
PR0547897
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/4/2024 9:47:39 AM
Creation date
10/5/2022 4:33:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0547897
PE
1624
FACILITY_ID
FA0027305
FACILITY_NAME
T4 TEA FOR LP
STREET_NUMBER
15346
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
15346 S HARLAN RD
P_LOCATION
07
QC Status
Approved
Scanner
SJGOV\lsauers1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NONLOAD-BEARING SCREWABLE STEEL STUDS AND JOISTS LEGEND: <br /> STEEL STUD MANUFACTURER'S ASSOCIATION - ICC ESR-2620 EXISTING PLYWOOD ROOF OR <br /> INTERIOR PARTITION—5 P.S.F. CEILING—4 P.S.F. W U) FLOOR SHEATHING - ATTACHMENT E <br /> W STUDS ONLY— SEE NOTE 8 0 <br /> m mo THROUGH SHEATHING PROHIBITED <br /> STUD STUD SPACING JOIST SPACING $ a Z> EXISTING PLYWOOD ROOF OR 2x BLOCKING BETWEEN FRAMING a N <br /> SIZE o FLOOR SHEATHING - ATTACHMENT <br /> 12" 16" 24" 12" 16" 24" N <br /> a THROUGH SHEATHING PROHIBITED MEMBERS - DEPTH EQUAL TO �+ C\I E Cf) <br /> 5/8p 9'-7" 8' CENTER <br /> 8" T-7" 8'-2" T-5" 6'-6" o FRAMING MEMBERS AT 24" ON 5/8" SOLID GYPSYM BOARD, FLAT FINISH (NO TEXTURE) Z (LS LO �, <br /> 2 1/2" 13'-3" 12'-0" 10'-2"f 11'-4" 10'-3" 9'-0" W <br /> 25 3 5/8 17'-3" 15-1"f 12'-4"f 13'-3" 12'-3" 10'-10" <br /> o EXISTING ROOF OR FLOOR <br /> FRAMING -2x MINIMUM MEMBER EXISTING ROOF JOISTS W Q N <br /> 4" 18'-8" 16'-2"f 13'-2"f - - - N SIZE - ATTACHMENT THROUGH FRAMING - 2x MINIMUM MEMBER Q U m CO <br /> _ _ m V) <br /> 6" - - - - ui z PLYWOOD WEBS OF TRUSS + SIZE - PROVIDE WEB BLOCKING w °� r <br /> 1 5/8" 12'-0" 10'-0" 9'-6" 10'-3" 9'-4" 8'-1" "' MEMBERS PROHIBITED AT TRUSS MEMBERS w Q N <br /> a O 2X4 ACOUSTICAL DROP CEILING - STANDARD > I <br /> 2 1/2" 16'-7" 15'-1" 13'-2" 14'-2" 12'-10 11'-3" m N \ z_ 5/16" EYE SCREW (4) 16d NAILS PER BLOCK <br /> = p BRAND: USG FROST, SLB EDGE <br /> 20 3 5/8" 21'-6" 19'-6" 17'-1" 16'-3" 15'-0" 13'-6" x C <br /> 18'-11" M m COLOR: WHITE w LL <br /> uj <br /> 00 Co <br /> 6" 33'-1" 30'-1" 26'-3" 18'-10 17'-6" 15'-9" $ w -71 R �} E is <br /> FOR KITCHEN AND FOOD PREP AREAS: 0? W w <br /> 1. LIGHT GAUGE METAL FRAMING DIMENSIONS SHALL BE 6. ALL SPANS AND HEIGHTS REFLECT AN L/120 MAXIMUM (4) 1 1'/4" WOOD SCREWS 2X4 ACOUSTICAL DROP CEILING - STANDARD Q 00 <br /> NO SMALLER THAN THOSE SPECIFIED ON THE DRAWINGS DEFLECTION FOR WALLS AND L/240 MAXIMUM FOR BRAND: CELOTEX 24"X48" � <br /> 2. THE SCHEDULE DOES NOT APPLY TO BEARING CEILING SPANS. <br /> WALLS, FLOORS OR CEILINGS. 7. NONLOAD-BEARING CEILING SHALL NOT BE WALKED COLOR: WHITE <br /> 3. ALL METAL FRAMING MEMBERS AND PARTS SHALL ON OR USED FOR STORAGE OF ANY KIND. BOTH % (4) TIGHT TURNS 3 5/8" x 20 GAUGE METAL STUD TYPE: VINYL SMOOTH SURFACE <br /> CONFORM WITH ANSI SPECIFICATIONS FOR DESIGN FLANGES OF JOISTS SHALL BE LATERALLY ��� `2 WITHIN 1 1/2" <br /> OF COLD STEEL STRUCTURAL MEMBERS. AST A 446 SUPPORTED. <br /> GRADE A. & HEIGHT'S SHOWN FOR STUDS ONLY SHALL ALSO APPLY f}�J <br /> 4. ALL FRAMING DETAILS SHALL CONFORM WITH 2010 TO NONLOAD-BEARING INTERIOR PARTITIONS WITH 10 GAUGE BRACING WIRE 24"X48" LAY-IN RECESSED FLUORESCENT FIXTURE, NSA CIS <br /> C.B.C. OR GYPSUM BOARD ASSOCIATION HANDBOOK. GYPSUM BOARD ONE SIDE APPROVED PRISMATIC LENS AND ELECTRONIC BALLAST <br /> 5. SCHEDULE APPLES TO NON-BEARING INTERIOR 9. CEILING SPAN VALUES ARE FOR SINGLE, FULLY <br /> PARTITIONS WITH GYPSUM BOARD ONLY. NO BRACED SPANS. <br /> ALLOWANCES MADE FOR CASEWORK OR <br /> N <br /> OTHER LOADING. 24"X24" LAY-IN RECESSED FLUORESCENT FIXTURE, NSA <br /> ROOF JOIST CONNECTION DETAIL APPROVED PRISMATIC LENS AND ELECTRONIC BALLAST <br /> STUD SCHEDULE WIRE BRACING DETAIL 2 SCALE: NONE 1 <br /> SCALE: NONE SCALE: NONE ++ <br /> C W O �= N <br /> ' O p U <br /> —EXISTING PLYWOOD ROOF OR ° >,v <br /> 2 FLOOR SHEATHING - ATTACHMENT CHANDELIER W/ DIMMER p o t v+'� 3 ., <br /> WALL OR PARTITION - - 2 EXTRA #12 HANGER WIRE ® EA. CORNER THROUGH SHEATHING PROHIBITED 11X3 .0 .0- o v p~ E °�' <br /> REFER TO PLAN OF FIXTURE, ATTACHED TO STRUCTURE ABOVE +;v v�� u <br /> AND ATTACHED TO FIXTURE BODY RECESSED CANS LIGHT BULB TRIM (E) N- ° +,- <br /> EXISTING ROOF JOISTS a 4� o o o�_ <br /> 1-1/2" COLD ROLLED TO TAB PROVIDED WITH FIXTURE WITH THREE ® FZPAINTED TO MATCH CEILING COLOR. (N} <br /> CONTINUOUS METAL TRACK CHANNEL WHERE SPAN TIGHT TURNS WITHIN 1 1/2", <br /> KI HEN H ODaa�ivo��3 � <br /> AT WALL EXCEEDS 10'-0" TWO WIRES MINIMUM PER FIXTURE. a� p " a rn <br /> RECESSED CANS LIGHT EYEBALL TRIM p a c E,n � <br /> N WALL WASHER LINGHT m v, v- a�, o.E v <br /> O \ GRID SUPPORT WIRES BY OTHERS E L' ai o ` U ° ° °' <br /> �.y <br /> AT EACH CORNER OF FIXTURE, TYP. + ® SPEAKER CEILING MOUNTED SEE SPEC BOOK FOR DETAILS a o a (D v c 6 LD U <br /> HEIGHT VARIES .-� a� Q-p L v C: <br /> REFER TO PLANS O ` x 7' o E C - v <br /> ADJUSTABLE "T-BAR" LOCK CLIP FOR +p E W 0 0-0) U �'E o a, <br /> W 41 N 7 N <br /> 3-5/8"X25 GAUGE METAL POSITIVE ATTACHMENT OF FIXTURE TO { ) U °-v ° °' ' v <br /> JOISTS AT 16" ON CENTER "T-BAR". PROVIDE (2) @ EA. END OF SURFACE MOUNTED PENDANT LIGHT .8' A.F.F ° v °' E�'� <br /> z 1 FIXTURE. � aNi �vQ- In0Q0 <br /> Q REFER TO STUD SCHEDULE _ ° ` ° rsn ` c_o w <br /> (4) 1 1'/4" WOOD SCREWS REMOVE EXIT N 2 ° v <br /> CEILING & "T-BAR" SUSPENSION m- C, <br /> ° SUPPLY DIFFUSER PAINT TO MATCH ADJACENT CEILING °� °� u,w <br /> w N'p n-0 U 7 <br /> p 24"X24" AT ACOUSTICAL CEILING LOCATIONS t 0 > 0 a�Q�N t p <br /> vT 5/8" GYPSUM BOARD (TYPE "X" 3 5/8" x 20 GAUGE METAL STUD 14"X14" AT GYPSUM SUSPENDED CEILING LOCATIONS (R/E) v a `w i W .� Q <br /> w ® 'ONE-HOUR' CONSTRUCTION) ® .• 3 E 3 Q°o Q <br /> o (2) #10 SELF TAPPING PAN HEAD <br /> SHEET METAL SCREWS AT EACH STUD <br /> FINISHED FLOOR RETURN AIR GRILLE PAINT TO MATCH ADJACENT CEILING REVISIONS/DATE <br /> 24"X24" AT ACOUSTICAL CEILING LOCATIONS <br /> 14"X14" AT GYPSUM SUSPENDED CEILING LOCATIONS D <br /> LIGHT FIXTURE BODY & DOOR (SCHEMATIC). <br /> TOILET ROOM EXHAUST FAN DUCTED TO ROOF <br /> ROOF JOIST CONNECTION DETAIL ® U <br /> GYPSUM BOARD CEILING LIGHT FIXTURE ATTACHMENT SCALE` "ro"'E 2 Ir <br /> � 4 SURFACE MOUNTED DUAL HEAD EMERGENCY <br /> SCALE: NONE `J SCALE: NONE 4=15LIGHT/EXIT SIGN 120V W/ BATTERY BACKUP -8' A.F.F �. <br /> IXIT <br /> R R TRACK LIGHT (48" LONG TRACK) 10'(} <br /> FOR PERPENDICULAR CONDITION 0" A.F.F <br /> CLIP FLANGES / FOLD WEB ATTACH <br /> EXISTING FLOOR OR ROOF EXISTING FLOOR OR ROOF W/ (4) #8 X 1 1/2" WOOD SCREWS. A <br /> SHEATHING - NO ATTACHMENT SHEATHING - NO ATTACHMENT ICC ESR-2196 <br /> THROUGHT SHEATHING ALLOWED THROUGHT SHEATHING ALLOWED <br /> EXISTING FRAMING MEMBER EXISTING FRAMING MEMBER EXISTING PLYWOOD ROOF OR pkESS�AIl� <br /> 2x MINIMUM FLOOR SHEATHING - ATTACHMENT y NDN O <br /> BLOCKING BETWEEN FRAMING THROUGH SHEATHING PROHIBITED q , <br /> EYE SCREW WITH 1 1/4" MINIMUM MEMBERS AS REQUIRED <br /> PENETRATION EXISTING ROOF OR FLOOR JIT71 NO. 63640 <br /> FRAMING -2x MINIMUM MEMBER {E) * Exp. 09/30/2022 <br /> SIZE - PROVIDE WEB BLOCKINGLLJ <br /> O( O 4 ) TIGHT TURNS ON SPLAY AT TRUSS MEMBER. C <br /> WIRES, TYPICAL AT EACH END + OR 2X WOOD BLOCKING AS NEEDED `/ V <br /> EYE SCREW WITH 1 1/4" MINIMUM BETWEEN STRUCTURAL FRAMING. <br /> 12 GAUGE SUSPENSION WIRE AT PENETRATION <br /> 4'-0" ON CENTER EACH DIRECTION 2x BLOCKING - DEPTH EQUAL <br /> ( 3 ) TIGHT TURNS ON SUSPENSION TO FRAMING MEMBER 4 <br /> 12 GAUGE SPLAY WIRE AT 45 WIRES, TYPICAL AT EACH END s <br /> DEGREES IN (4) DIRECTIONS AT 1 1/4" DIAMETER ELECTRICAL (4) 1 1/2" WOOD SCREWS,ICC ESR-2'96 <br /> 12'-0" ON CENTER EACH WAY METALLIC METING COMPRESSION 3 5/8" x 20 GAUGE METAL STUD <br /> POST - TIGHT TO STRUCTURE BRACE AT 4'-0" O.C. ALTERNATING <br /> ( 3 ) TIGHT TURNS ON SUSPENSION 3 >_ CONTRACTORS OPTION: W/ (4) #8 X 1 1/2" WOOD SCREWS <br /> WIRES, TYPICAL AT EACH END '` TO ROOF FRAMING EACH LEG. SIZE <br /> e w PROVIDE AN ICC-ES ESR-1222 AND GAUGE TO MATCH STUD WALL <br /> > PRE-MANUFACTURED COMPRESSION ADD ADDITIONAL BRACE AT STRIKE <br /> NOTE: o STRUT INSTALLED PER SIDE OF DOOR <br /> ( 3 ) WIRES MAXIMUM PER SCREW uj MANUFACTURERS RECOMMENDATIONS STUD BRACING DETAIL 3 (E> <br /> SCALE: NONE <br /> 1 1/4" DIA. ELECTRICAL METALLIC STRUCTURE ABOVE [\(\E) <br /> FACE OF WALL OR PARTITION TUBING COMPRESSION PST AT 3 <br /> 12 GAUGE SUSPENSION WIRE AT 12'-0" ON CENTER H WAY - - <br /> 4'-0" ON CENTER EACH DIRECTION 12 GA. SUSPENSI WIRE INSIDE o <br /> COMPRESSION ST (DASHED) <br /> 8" MAXIMUM 1/8" DIA. LT AND LOCKING NUT C <br /> THROU 5/32" DIAMETER HOLErze <br /> ANCHORAGE TO WALL AS 1 1/ DIA. ELECTRICAL METALLIC Q <br /> REQUIRED AT 32" ON CENTER TVE <br /> GHT OVERSLEAIN R NNERVE - NOTCH TO FIT <br /> 12 GUAGE SPLAY WIRE AT [� Q <br /> MAIN RUNNER OR CROSS TEE 45 DEGREES - (4) DIRECTIONS ac <br /> 12'-O" ON CENTER EACH T- AR CEILING @ 12' AFF " " o O <br /> DIRECTION - SPLAY WIRES mj oCS <br /> I I I I I I I I I I I I I I I I I I I I 1 1 1 1 1 1 III I L I I SHALL NOT BE ATTACHED <br /> TO CROSS TEES - T-BAR CEILING ® 10' FF {E) <br /> c,Q <br /> MAIN RUNNER - LEVEL PRIOR C Q <br /> LAY-IN ACOUSTICAL PANEL TO SETTING COMPRESSION POST NJ7 J*ZJ =j <br /> WALL CLOSURE ANGLE WITH 20 GA, 2" 2" 2" LAY-IN ACOUSTICAL PANEL, TYPICAL <br /> 1Z (R/ ) <br /> LEGS - RIVET EACH RUNNER OR MAXIMUM, TYPICAL CROSS TEE '(R A.F.F <br /> FIXED END CROSS TEE TO ANGLE L3 5/8" x 20 GAUGE METAL STUD <br /> AT TWO ADJACENT WALLS OR PARTITIONS VERTICAL COMPRESSION STRUT BRACE AT 16" O.C. <br /> NOTES: SOFFIT DETAIL <br /> : � 'I" <br /> SUSPENDED CEILINGS IN SEISMIC DESIGN CATEGORIES D, E, AND F SHALL BE DESIGNED SCALE NONE E <br /> 12 GAUGE SUSPENSION WIRE AND INSTALLED IN ACCORDANCE WITH ASTM C635, ASTM 636 AND THE CISCA FOR <br /> AT 4'-0" ON CENTER EACH WAY SEISMIC ZONES 3-4 AS MODIFIED BY THE FOLLOWING €13.5.6.2.2 ASCE 7-051: <br /> FACE OF WALL OR PARTITION A. A HEAVY DUTY T-BAR GRID SYSTEM SHALL BE USED. <br /> B. THE WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE SHALL BE NOT <br /> SLOTTED ANGLE SPACER - LESS THAN 2 INCHES; IN EACH ORTHOGONAL HORIZONTAL DIRECTION, ONE END <br /> 2" x 2" x 20 GAUGE NOTCHED OF THE CEILING GRID SHALL BE ATTACHED TO THE CLOSURE ANGLE. THE OTHER Drawn By A. DANG <br /> ANGLE END IN EACH HORIZOTAL DIRECTION SHALL HAVE A 0.75 INCH CLEARANCE FROM <br /> THE WALL AND SHALL REST UPON AND BE FREE TO SLIDE ON THE CLOSURE Chocked By <br /> MAIN RUNNER OR CROSS TEE ANGLE. <br /> C. FOR CEILING AREAS EXCEEDING 2500 SQ. FT., A SEISMIC SEPARATION JOINT OR 1771 Date 10-28-21 <br /> OF FULL HEIGHT PARTITION THAT BREAKS THE CEILING UP INTO AREAS NOT <br /> ;I,I,I;I,ilili j i i i i i i i i i l l I i I i I I I I I I I i I WALL CLOSURE ANGLE WITH EXCEEDING 2500 SQ, FT. SHALL BE PROVIDED UNLESS A STRUCTURAL ANALYSIS Scale <br /> 2" LEGS IS PERFORMED. IT <br /> D. SPRINGKLER HEADS AND OTHER PENETRATIONS SHALL HAVE A 2 INCH OVERSIZE Job No. AS NOTED <br /> 1/2" CLR RING, SLEEVE, OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FREE <br /> MOVEMENT OF AT LEAST 1 INCH IN ALL HORIZONTAL DIRECTIONS. <br /> LAY-IN ACOUSTICAL PANEL E. CHANGES IN CEILING PLAN ELEVATION SHALL BE PROVIDED WITH POSITIVE <br /> 8" MAXIMUM BRACING. <br /> FREE END F. LIGHT FIXTURES, CABLE TRAYS, AND ELECTRICAL CONDUITS SHALL BE CEILING PLAN <br /> SUPPORTED INDEPENDENTLY OF THE CEILING. <br /> AT TWO ADJACENT WALLS OR PARTITIONS G. SUSPENSION WIRES SHALL NOT BE SMALLER THAN NO. 12 GAGE SPACED AT 4 <br /> FEET ON CENTER NOR HANG MORE THAN 1 IN 6 OUT OF PLUMB. <br /> H. THE PERIMETER ENDS OF EACH CROSS RUNNER AND MAIN RUNNER SHALL BE <br /> Drawing No. <br /> SUPPORTED A MAXIMUM OF 8 INCHES FROM WALL. <br /> I. LATERAL FORCE BRACING MEMBERS SHALL BE SPACED A MINIMUM OF 6 INCHES <br /> FROM ALL HORIZONTAL PIPING OR DUCT WORK. C C I L NIGP L/� <br /> 11 <br /> 2 <br /> CEILING SUSPENSION DETAIL SCALE: 1//4" = 1' AE=l �J LJ ❑ <br /> SCALE: NONE � I <br /> Of Sheets <br />
The URL can be used to link to this page
Your browser does not support the video tag.