Laserfiche WebLink
60" MIN. CLEAR 54" MIN. FLUSH-MOUNTED <br /> TOILET SEAT COVER DISPENSER <br /> TO ADJACENT FIXTURE42" MIN. 12" MAX. BOBRICK "CONTURA" B-4221 MN. 5/8 "AAND MAX. OF 2" HIGH, DISABLED ACCESSIBILITY GENERAL NOTES _ 0 <br /> 17"-18" RAISED MIN. 1/32" �.� <br /> N L j <br /> 24 MIN. EX HORIZONTAL FORMAT.ERCASE. r� Z ca � co <br /> 1 1/2" DIAMETER STAINLESS STEEL 42" MIN. `.J <br /> 1. MIN. CLR. FLR. OR GROUND SPACE REQUIRED TO ACCOMMODATE A 2. THE UPPER APPROACH AND THE LOWER TREAD OF EACH INTERIOR 3. TOILET AND URINAL FLUSH CONTROLS SHALL BE OPERABLE WITH 5 0) 00 <br /> FLUSH ACTIVATION LEVER SHALL BE � W � Q � N <br /> INSTALLED ON WIDE SIDE SINGLE, STATIONARY WHEELCHAIR AND OCCUPANT IS 30" X 48". MIN. STAIR SHALL BE MARKED BY A STRIP OF CLEARLY CONTRASTING COLOR ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR <br /> GRAB BAR, TYP. CLR. FLR. OR GROUND SPACE FOR WHEELCHAIRS MAY BE POSITIONED AT LEAST 2 INCHES WIDE AND PLACED PARALLEL TO, AND NOT MORE TWISTING OF THE WRIST. CONTROLS FOR THE FLUSH VALVES SHALL W Q U m C4 <br /> FLUSH-MOUNTED MULTI-ROLL FOR FORWARD OR PARALLEL APPROACH TO AN OBJECT. FLOOR OR THAN, 1 INCH FROM THE NOSE OF THE STEP OR LANDING TO ALERT BE MOUNTED ON THE OPEN (WIDE) SIDE OF THE TOILET STALL, NO w '- <br /> TOILET TISSUE DISPENSER PROFILE IN WHITE GRADE 2 BRAILLE WITH DOTS 1/10" ON CENTER GROUND SPACE FOR WHEELCHAIRS MAY BE PART OF THE KNEE SPACE THE VISUALLY IMPAIRED. THE STRIPE SHALL BE OF A MATERIAL THAT MORE THAN 44 INCHES ABOVE THE FLOOR. THE FORCE REQUIRED TO 'Z t� <br /> TOILET - FLOOR OR WALL MOUNTED ON BLUE BACKGROUND AND 2/10' SPACE BETWEEN CELLS RAISED REQUIRED UNDER SOME OBJECTS. IS AT LEAST AS SLIP RESISTANT AS THE TREADS OF THE STAIR. ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 LBS. Z C) O <br /> REFER TO PLUMBING DRAWINGS - MINIMUM 1/40 SHALL BE PLACED A MIN. OF <br /> o I o w 3/8" AND A MAX. 1/2" DIRECTLY BELOW THE 2. ALCOVES SHALL BE 60 INCHES (1524 MM) WIDE MINIMUM WHEN THE 3. WHERE STAIRS OCCUR OUTSIDE OF A BUILDING, THE UPPER 4. WHERE URINALS ARE PROVIDED, AT LEAST ONE SHALL HAVE A 00 <br /> I TACTILE CHARACTERS; FLUSH LEFT OR CENTERED. APPROACH AND ALL TREADS SHALL BE MARKED BY A STRIP OF 00 <br /> _1 <br /> DEPTH EXCEEDS 15 INCHES (381 MM) FOR SIDE APPROACH. CLEAR SPACE 30 INCHES WIDE BY 48 INCHES LONG IN FRONT OF THE w <br /> C) o" EXIT BRAILLE DOTS SHALL BE DOMED R ROUNDED. a E <br /> � N CLEARLY CONTRASTING COLOR AT LEAST 2 INCHES WIDE AND PLACED URINAL. AT LEAST ONE URINAL WITH A RIM PROJECTING A MINIMUM OF Q � W w <br /> (LETTERS AND SYMBOLS TO COMPLY PARALLEL TO, AND NOT MORE THAN 1 INCH FROM THE NOSE OF THE <br /> < 7"_9" WITH CBC 11B-703.3) 3. ALCOVES SHALL BE 36 INCHES (914 MM) WIDE MINIMUM WHEN THE 14 INCHES FROM THE WALL (CALIFORNIA ONLY) AND A MAXIMUM OF 17 <br /> w `� STEP OF LANDING TO ALERT THE VISUALLY IMPAIRED. THE STRIP LO <br /> ROUTE DEPTH EXCEEDS 24 INCHES (610 MM) FOR FRONT APPROACH. INCHES ABOVE THE FLOOR SHALL BE INSTALLED. OD <br /> SHALL BE OF A MATERIAL THAT IS AT LEAST AS SLIP-RESISTANT AS <br /> v 6' M 36" MIN. EXIT ROUTE (tactile exit sign) THE TREADS OF THE STAIR. A PAINTED STRIPE SHALL BE ACCEPTABLE. 5. A CLEAR FLOOR SPACE 30 INCHES WIDE BY 48 INCHES LONG <br /> 12" 24" Size: 6 in. x 8 in for 5/8 to 1 in high text SHALL BE PROVIDED IN FRONT OF A LAVATORY TO ALLOW FORWARD IL <br /> g HAZARDS AND PROTRUDING OBJECTS ALL STAIR TREAD SURFACES SHALL BE SLIP-RESISTANT. APPROACH. SUCH CLEAR SPACE SHALL ADJOIN OR OVERLAP AN ti <br /> 1 1/2" DIAMETER STAINLESS STEEL 36" MIN. HANDRAILS ACCESSIBLE ROUTE AND SHALL EXTEND INTO KNEE AND TOE SPACE <br /> M - GRAB BAR-"BOBRICK" #8-6206.99x36 1. OBJECTS PROJECTING FROM WALLS WITH THEIR LEADING EDGES UNDERNEATH LAVATORY. <br /> NOTE: BETWEEN 27 INCHES AND 80 INCHES ABOVE THE FINISHED FLOOR 0) <br /> C:) " FLUSH VALUE OR TRIP LEVER SHALL PROTRUDE NO MORE THAN 4 INCHES INTO WALKS, HALLS, 1. HANDRAILS AT STAIRWAYS SHALL BE 34 INCHES TO 38 INCHES <br /> 33 TO 36" TO TOP El ON WIDE SIDE OF TOILET STALL 1. Signs with raised characters and Braille shall be located 48 inches (1220 mm) minimum above the finish floor CORRIDORS, PASSAGEWAYS, OR AISLES. ABOVE THE NOSING OF THE TREADS. 6. LAVATORIES SHALL BE MOUNTED WITH A CLEARANCE OF AT LEAST <br /> OF GRIPPING SURFACE w ground surface, measured from the baseline of the lowest line of Braille and 60 inches (1525 mm) maximum 29 INCHES FROM THE FLOOR TO THE BOTTOM OF THE APRON WITH (D <br /> FOR THE REAR 36" GRAB BAR: above the finish floor or ground surface, measured from the baseline of the highest line of raised characters. KNEE CLEARANCE UNDER THE FRONT LIP EXTENDING A MINIMUM OF 30 <br /> Ll 33" FOR FLUSH 9 p y pp ( ) signage 2. OBJECTS MOUNTED WITH THEIR LEADING EDGES AT OR BELOW 27 2• HANDRAILS AT THE TOP OF STAIRWAYS SHALL EXTEND A MINIMUM INCHES IN WIDTH WITH 8 INCHES MINIMUM DEPTH AT THE TOP. TOE <br /> without location shall t determined so that a person may roach within 3 inches 76 mm of si nae OF 12 INCHES OF LEVEL DISTANCE BEYOND THE TOP NOSING. CLEARANCE SHALL BE SAME WIDTH AND A MINIMUM OF 9 INCHES HIGH <br /> VALVE TOILETS without encountering protruding objects or standing within the swing of a door. INCHES ABOVE THE FINISHED FLOOR MAY PROTRUDE ANY AMOUNT. <br /> 33" TO 36" FOR TANK HANDRAILS AT THE BOTTOM OF STAIRWAYS SHALL EXTEND A MINIMUM FROM THE FLOOR AND7T A MINIMUM OF 17 INCHES DEEP FROM THE <br /> TYPE TOILETS 3. FREE-STANDING OBJECTS MOUNTED ON POSTS / PYLONS MAY OF TREAD WIDTH PLUS 12 INCHES BEYOND THE BOTTOM NOSING FRONT OF THE LAVATORY. SIDE APPROACH TO LAVATORIES SHALL BE c 0 ° 0- °' <br /> OVERHANG 12 INCHES MAXIMUM FROM 27 INCHES TO 80 INCHES BEFORE THEY ARE RETURNED. AT THE BOTTOM, THE HANDRAIL SHALL 0 t <br /> CONTINUE TO SLOPE FOR A DISTANCE OF THE WIDTH OF ONE TREAD 24" MIN. FROM ADJACENT WALL FINISH. <br /> TACTILE EXIT SIGNAGE INTL SYMBOL OF ACCESSIBILITY ABOVE THE GROUND OR FINISHED FLOOR. o o Ct 3 a <br /> NONE 1 7•FROM THE BOTTOM RISER. THE REMAINDER OF THE EXTENSION IS HOT WATER AND DRAIN PIPES UNDER LAVATORIES SHALL BE =U ° 0~ <br /> SCAM E EID <br /> : 4. PROTRUDING OBJECTS SHALL NOT REDUCE THE REQUIRED CLEAR HORIZONTAL (LEVEL). INSULATED OR OTHERWISE COVERED. THERE SHALL BE NO SHARP OR +' m <br /> ACCESSIBLE TOILET WIDTH OF AN ACCESSIBLE ROUTE OR MANEUVERING SPACE. ABRASIVE SURFACES UNDER LAVATORIES. N 06.2-° o-0 010:5 4 <br /> 3. WHERE THE EXTENSION OF THE HANDRAIL IN THE DIRECTION OF 0 °-o�, -� o <br /> 5. ANY OBSTRUCTION OVERHANGING A PEDESTRIAN WAY SHALL BEA THE STAIR RUN WOULD CREATE A HAZARD, THE EXTENSION SHALL BE g, MIRRORS SHALL BE MOUNTED WITH BOTTOM EDGE OF THE ° 0-a; 0 0 °"d.3 at <br /> MADE AT RIGHT ANGLES, ON THE FACE OF A RETURNING WALL. o 0 •t 0 2 C c rn- 0 <br /> MIRROR AS OCCURS MINIMUM OF 80 INCHES ABOVE THE WALKING SURFACE AS MEASURED REFLECTIVE SURFACE NOT MORE THAN 40 INCHES FROM THE FLOOR. ° <br /> TO THE BOTTOM OF THE OBSTRUCTION. WHERE THE STAIRS ARE CONTINUOUS THE HANDRAIL SHALL BE 0 v, 0= vt 2•- a <br /> 0 -+, � �v <br /> O SURFACE-MOUNTED SOAP DISPENSER SIGN ON DOOR: CONTINUOUS AND NEED NOT EXTEND OUT INTO THE LANDING. rn at o T o c > <br /> 9. LOCATE PAPER TOWEL DISPENSERS, SANITARY NAPKIN DISPENSERS, at in 0 0 0 at <br /> A " PARKING AND AND WASTE RECEPTACLES WITH ALL OPERABLE PARTS NOT MORE 3` v` a ° ° � 0 <br /> ALL PIPES AND VALVES SHALL BOBRICK CONTURA B-4112 4. HANDRAILS ARE REQUIRED ON RAMPS WHEN THE SLOPE EXCEEDS o 0 0-L c 0_ 2 J <br /> U-1 BLUE EQUILATERAL THAN 40 INCHES FROM THE FLOOR. . �, o - a a,�, ° 6 J <br /> OCCUR WITHIN AREA SHOWN SHADED ¢ WALL OR PARTITION AS OCCURS, TYPICAL TRIANGLE 12" LONG EACH 1. SURFACE SLOPES OF PARKING SPACES FOR THE PHYSICALLY 1:20 (5%). HANDRAILS AT RAMPS SHALL RUN ALONG BOTH SIDES OF A ° o <br /> SIDE 1/4" THICK RAMP BE CONTINUOUS THE FULL LENGTH AND EXTENSIONS AT THE oat ° r- 2 <br /> DISABLED SHALL NOT EXCEED 1/4 INCH PER FOOT (2% GRADIENT) IN 10. LOCATE TOILET TISSUE DISPENSERS ON THE WALL SHALL BE 7" TO vt amt ° at at v (D > °"' <br /> DOOR FRAME ANY DIRECTION. TOP AND BOTTOM OF THE RAMP SHALL COMPLY WITH ITEM NUMBER 2, o o C 0 E <br /> Q NOTES: " 9" FROM THE FRONT EDGE OF THE TOILET SEAT TO THE CENTER LINE 3- Q° ° 0 C <br /> t"E at o _ <br /> FAUCETS SAHLL BE LEVER TYPE, ELECTRONICALLY 18 MIN. ABOVE. OF THE DISPENSER. 3 C: mat <br /> N OPERATED OR APPROVED SELF-CLOSING � ' 2. DISABLED PARKING SPACES SHALL BE LOCATED SO AS NOT TO o F s N T•°_ o Ld <br /> C14 W/ 10 SECONDS MIN. FLOW 30" EDGES AND VERTICES REQUIREMENTS: REQUIRE USERS TO WHEEL OR WALK BEHIND ANY OTHER 5. THE HANDRAIL GRIP SURFACE AT RAMPS SHALL BE MOUNTED 11. A CLEAR SPACE, MEASURED FROM THE FLOOR TO A HEIGHT OF 27 at at"-' ai v ao.v 'w <br /> ' Edges shall be eased or rounded at 1/16 inch (1.59 NON-DISABLED OR DISABLED PARKING SPACE. BETWEEN 34 INCHES AND 38 INCHES ABOVE THE RAMP SURFACE. ° ° 0 0 0 Q v at <br /> CLEAR, MINIMUM FINISH FLOOR mm) minimum, or chamfered at 1/8 inch (3.2 mm) ALL-GENDER INCHES ABOVE THE FLOOR, WITHIN THE SANITARY FACILITY ROOM, OF sat 0 L at D v,t o <br /> FAUCETS SHALL BE OPERABLE W/ ONE HAND o maximum. Vertices shall be radiused between 1 8 RESTROOM 6. ALL HANDRAIL ENDS SHALL BE RETURNED OR SHALL TERMINATE IN SUFFICIENT SIZE TO INSCRIBE A CIRCLE OF A DIAMETER NOT LESS s IE 0 �,(D a V 0 Q <br /> 24 & NOT REQUIRE TIGHT GRASPING, PINCHING / 3. IN EACH PARKING AREA, A BUMPER OR CURB SHALL BE PROVIDED THAN 60 INCHES, OR A CLEAR SPACE NOT LESS THAN 56 INCHES X v, E 3 C`i-o o <br /> inch (3.2 mm) minimum and 1/4 inch (6.4 mm) <br /> OR TWISTING OF THE WRIST. AND LOCATED TO PREVENT ENCROACHMENT OF CARS OVER THE NEWEL POSTS OR SAFETY TERMINALS. <br /> 63 INCHES IN SIZE SHALL BE PROVIDED. DOORS OTHER THAN THE <br /> 6" 8" 7 maximum. R REQUIRED WIDTH OF WALKWAYS. DOOR TO THE DISABLED TOILET COMPARTMENT, IN ANY POSITION, MAY <br /> MIN 16 7. ALL HANDRAILS PROJECTED FROM A WALL SHALL HAVE AN NOT ENCROACH INTO THIS SPACE BY NOT MORE THAN 12 INCHES. REVISIONS DATE <br /> 11" FINISH FLOOR MIRROR AS OCCURS 4. PARKING SPACES RESERVED FOR PERSONS WITH PHYSICAL ABSOLUTE CLEARANCE OF 1-1/2 INCHES BETWEEN THE WALL AND THE <br /> 18" MI DISABILITIES SHALL BE IDENTIFIED BY A REFLECTORIZED SIGN HANDRAIL. 12. AN ACCESSIBLE INDIVIDUAL TOILET STALL SHALL BE 60 INCHES <br /> 17" ,4 PERMANENTLY POSTED IMMEDIATELY ADJACENT TO AND VISIBLE FROM MEASURED PERPENDICULAR FROM THE SIDE WALL. A 48 INCH LONG <br /> MIN OLAVATORY-MOUNTED SOAP DISPENSER THE ALL GENDER RESTROOM SHALL BE IDENTIFIED BY A CENTER ID SYMBOL ON M EACH STALL OR SPACE, CONSISTING OF A PROFILE VIEW OF A 8. THE HANDGRIP PORTION OF HANDRAILS SHALL BE NOT LESS THAN <br /> "BOBRICK" 822 CIRCLE, %*THICK AND 12"IN DIAMETER WITH A WHEELCHAIR WITH OCCUPANT, IN WHITE ON DARK BLUE BACKGROUND. 1-1/4 INCH NOR MORE THAN 1-1 2 INCH IN CROSS-SECTIONAL CLEAR SPACE IN FRONT OF WATER CLOSET SHALL BE PROVIDED IF THE'ol <br /> 1/4"THICK TRIANGLE SUPERIMPOSED ON THE CIRCLE / COMPARTMENT HAS AN END OPENING DOOR (FACING THE WATER <br /> VANITY AND WITHIN THE 12"DIAMETER, THE TRIANGLE SYMBOL THE SIGN SHALL NOT BE SMALLER THAN 70 INCHES IN AREA AND, DIMENSION OR THE SHAPE SHALL PROVIDE AN EQUIVALENT SMOOTH <br /> SHALL CONTRAST WITH THE CIRCLE SYMBOL, EITHER WHEN IN THE PATH OF TRAVEL, SHALL BE POSTED AT A MINIMUM GRIPPING SURFACE WITH NO SHARP CORNERS. CLOSET). A 60 INCH LONG CLEAR SPACE SHALL BE PROVIDED IN <br /> NOTE. LIGHr ON A DARK BACKGROUND OR DARK ON A LIGHT HEIGHT OF 80 INCHES FROM THE BOTTOM OFTHE SIGN TO THE COMPARTMENT WHEN DOOR IS LOCATED AT THE SIDE. GRAB BARS <br /> BACKGROUND PER CBC SECTION 11B-703.7.2.6.3. DOOR FRAME SHALL NOT PROJECT MORE THAN 3 INCHES INTO CLEAR SPACE <br /> ALL PIPES UNDER SINKS AND/OR PARKING SPACE FINISHED GRADE. SIGNS MAY ALSO BE CENTERED ON SPECIFIED ABOVE. <br /> < VANITIES SHALL BE WRAPPED WITH THE WALL AT THE INTERIOR END OF THE PARKING SPACE ATA RAMPS IF APPLICABLE) <br /> SECURELY ATTACHED, WHITE, PREFORMED MINIMUM HEIGHT OF 60 INCHES FROM THE PARKING SPACE FINISHED <br /> NEOPRENE INSULATION GRADE, GROUND, OR SIDEWALK. 13. WATER CLOSET COMPARTMENT SHALL BE EQUIPPED WITH DOOR Q <br /> 1. ALL RAMPS USED AS EXITS AND ANY PATH OF TRAVEL HAVING A THAT HAS AN AUTOMATIC CLOSING DEVICE, AND A CLEAR <br /> Z 30" WALKS AND SIDEWALKS SLOPE GREATER THAN 1:20 SHALL COMPLY WITH THE REQUIREMENTS UNOBSTRUCTED OPENING WIDTH OF 32 INCHES WHEN LOCATED AT THE <br /> � WALL OR PARTITION AS OCCURS, TYPICAL <br /> N CLEAR, MINIMUM OF THIS SECTION. RAMPS SHALL HAVE THE LEAST POSSIBLE SLOPE. END, AND 34 INCHES (CALIF. ONLY) WHEN LOCATED AT THE SIDE, <br /> 1. WALKS AND SIDEWALKS SHALL HAVE A CONTINUOUS COMMON WHEN THE DOOR IS POSITIONED AT AN ANGLE OF 90 DEGREES FROM <br /> 16 FINISH FLOOR SURFACE NOT INTERRUPTED BY STEPS OR BY ABRUPT CHANGES IN 2. PEDESTRIAN RAMPS SERVING PRIMARY ENTRANCES TO A BUILDING ITS CLOSED POSITION. Seal` <br /> NOTE: LEVEL WHICH EXCEED 1/2 INCH, AND SHALL BE A MINIMUM OF 48 SHALL HAVE A MINIMUM WIDTH OF 48 INCHES. RAMPS SERVING AN ESS/O1, <br /> Designation signs are not required to be provided by the CBC. If provided, a designation INCHES IN WIDTH. OCCUPANCY LOAD GREATER THAN 300 SHALL HAVE A MINIMUM WIDTH 14. EXCEPT FOR DOOR OPENINGS, A CLEAR UNOBSTRUCTED ACCESS NHAN O <br /> sign adjacent to the door must comply with the scoping requirements of CBC 11B-216.2, OF 60 INCHES. (CALIFORNIA ONLY) NOT LESS THAN 44 INCHES SHALL BE PROVIDED TO ALL WATER <br /> NOTE: and the technical requirements for raised characters (CBC 11B-703.2), braille (CBC 2. SURFACE CROSS SLOPES SHALL NOT EXCEED 1/4 INCH PER FOOT. CLOSET COMPARTMENTS DESIGNED FOR USE BY THE DISABLED. THE �ry <br /> IF A MINIMUM 9 INCHES HEIGHT OS TOE CLEARANCE IS 11B-703.3), visual characters (CBC 11B-703.5), and requirements for installation height 3. ALL RAMPS IN AREAS ACCESSIBLE TO PERSONS WITH DISABILITIES SPACE IMMEDIATELY IN FRONT OF A WATER CLOSET COMPARTMENT NO. 63640 <br /> FLOOR SPACE REQUIRED AT THE FIXTURE MAY EXTEND �^ <br /> PROVIDED, A MAXIMUM OF 6 INCHES OF 48 INCHES D CLEAR and location (CBC 11B-703.4). No pictogram is required. 3. WALKS, SIDEWALKS, AND PEDESTRIAN WAYS SHALL BE FREE OF ON A PATH OF TRAVEL OR SERVING EXITS SHALL HAVE A 1:12 SHALL BE NOT LESS THAN 48 INCHES AS MEASURED AT RIGHT ANGLES Ex 09 30 2022 <br /> INTO GRATING WHENEVER POSSIBLE. GRID OPENINGS WITHIN GRATINGS MAXIMUM SLOPE WITH CROSS SLOPES NO GREATER THAN 1:50. TO THE COMPARTMENT DOOR IN ITS CLOSED POSITION. * p' / / <br /> SINK AND VANITY THE TOE SPACE. <br /> LOCATED IN THE SURFACE OF ANY OF THESE AREAS SHALL BE LIMITED S'j, � V Q- <br /> TO 1/2 INCH IN THE DIRECTION OF THE TRAFFIC FLOW. 4. THE LEVEL LANDING WIDTH OF ANY RAMP SHALL EXTEND PAST THE 9 <br /> STRIKE EDGE OF ANY DOOR OR GATE AS SHOWN ON DETAIL NO. 2 ON GRAB BARS C <br /> RESTROOM ELEVATIONS AND PLAN ADA SIGNAGE 4. WHEN THE SLOPE IN THE DIRECTION OF TRAVEL OF ANY WALK THIS DWG. <br /> SCALE: NONE 2 SCALE: NONE 4 EXCEEDS 1 VERTICAL TO 20 HORIZONTAL, IT SHALL COMPLY WITH THE 1. GRAB BARS SHALL BE LOCATED ON ONE SIDE AND THE BACK OF <br /> PROVISIONS OF PEDESTRIANS RAMPS. 5. DOORS STANDING IN ANY POSITION SHALL NOT REDUCE THE THE PHYSICALLY DISABLED TOILET STALL OR COMPARTMENT AND SHALL <br /> MINIMUM DIMENSION OF THE RAMP TO LESS THAN 42 INCHES OR THE BE SECURELY ATTACHED 33 TO 36 INCHES ABOVE FINISHED FLOOR TO <br /> / <br /> SIGN AT MAIN EXIT DOOR WHEN KEY <br /> DIRECTION OF EGRESS ENTRANCES DOORS REQUIRED WIDTH BY MORE THAN 3 INCHES. (CALIFORNIA ONLY) THE TOP OF THE GRAB BAR AND PARALLEL TO THE FLOOR. <br /> LOCKING HARDWARE IS USED v 4'-0" <br /> CLEAR LEVEL FLOOR AREA BOLT THROUGH BACKING PLATE 1. 100% OF PRIMARY ENTRANCES AND EXTERIOR GROUND FLOOR EXIT 6. TRUNCATED DOMES ARE REQUIRED PER ADAAG, ON THE LEVEL 2. GRAB BARS AT THE SIDE SHALL BE AT LEAST 42 INCHES LONG <br /> DOOR (SEE DOOR SCHEDULE) (SHOWN OUTLINED) AT TOILET PARTITIONS-COORDINATE DOORS <br /> HIC <br /> TOBUILDINGSDISABLED <br /> FACILITIESAND SHALL <br /> BE BE ACCESSIBLE SSE IBTO 3'-0 DEEP PORTION OF ALL CURB RAMPS. WITH THE FRONT END POSITIONED 54 INCHES FROM THE BACK OF THE <br /> CLOSER - DOOR CLOSERS AND GATE CLOSERS METAL THRESHOLD WITH PARTITION MANUFACTURER THE PHYSICALLY <br /> OF TRAVEL. STALL, GRAB BARS AT THE BACK SHALL NOT BE LESS THAN 36 <br /> 1 1 SANITARY FACILITIES (GENERAL) INCHES LONG. <br /> SHALL BE ADJUSTED SO THAT FROM AN OPEN lo PROVIDE THIS ADDITIONAL SPACE 11 " <br /> POSITION OF 90 DEGREES, THE TIME REQUIRED IF DOOR IS EQUIPPED WITH BOTH 2 2 2. ALL ACCESSIBLE ENTRANCES SHALL BE IDENTIFIED WITH AT LEAST 1. ALL DOORWAYS LEADING TO SANITARY FACILITIES SHALL HAVE 32 3. THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A GRAB <br /> TO MOVE THE DOOR TO A POSITION OF 12 A LATCH AND A CLOSER. ONE STANDARD SIGN AND WITH ADDITIONAL DIRECTIONAL SIGNS, AS INCH CLEAR, UNOBSTRUCTED OPENINGS. BAR SHALL BE 1-1/4 INCHES OR THE SHAPE SHALL PROVIDE AN <br /> DEGREES FROM THE LATCH IS 5 SECONDS 2 0 2'_g" REQUIRED, VISIBLE FROM APPROACHING PEDESTRIAN WAYS. EQUIVALENT GRIPPING SURFACE. IF THE GRAB BARS ARE MOUNTED <br /> MINIMUM. CBC SECTION 11B-404.2.8.1. �1 2. ALL SINKS, FAUCET CONTROLS, AND OPERATING MECHANISMS SHALL ADJACENT TO A WALL, THE SPACE BETWEEN THE WALL AND THE GRAB <br /> MIN CLR 1 -0" 3. EVERY REQUIRED ENTRANCE OR PASSAGE DOORWAY SHALL BE OF A <br /> ENTRY - 4" SQUARE SELF-ADHESIVE VINYL 1 1/2" DIAMETER STAINLESS STEEL SIZE AS TO PERMIT THE INSTALLATION OF A DOOR NOT LESS THAN 36 BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT BARS SHALL BE 1-1/2 INCHES. <br /> GRAB BAR GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE <br /> INTERNATIONAL SYMBOL OF ACCESSIBILITY ON INCHES IN WIDTH, AND NOT LESS THAN 80 INCHES IN HEIGHT. DOORS REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 LBS. 4. GRAB BARS, AND ANY WALL OR OTHER SURFACE ADJACENT TO IT, <br /> WALL ADJACENT TO THE LATCH OUTSIDE OF DOOR N0�' SHALL BE CAPABLE OF OPENING AT LEAST 90 DEGREES AND SHALL BE LEVER-OPERATED, PUSH TYPE, AND ELECTRONICALLY CONTROLLED SHALL BE FREE OF ANY SHARP OR ABRASIVE ELEMENTS. GRAB BAR <br /> FOR EXTERIOR ENTRANCE WHEN NOT ALL MOUNTED SO THAT THE CLEAR WIDTH OF THE DOORWAY IS NOT LESS MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS. SELF-CLOSING EDGES SHALL HAVE A MINIMUM RADIUS OF 1/8 INCH. <br /> ENTRANCES ARE ACCESSIBLE; REFER TO DETAIL 1. CLEAR LEVEL FLOOR AREA ALL GRAB BARS SHALL CONFORM TO THAN 32 INCHES. <br /> FINISHED FLOOR (SHOWN CROSSHATCHED) o <br /> - :_]�� CBC 116-609.8 FOR STRUCTURAL VALVES ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST 10 <br /> _r_ THRESHOLD o FOR EXTERIOR DOORS z STRENGTH (TO WITHSTAND A MINIMUM 4. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND SECONDS. 5. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS. <br /> DOOR AND GATE HARDWARE. HANDLES, PULLS, SHEAR FORCE OF 250 LBS) <br /> LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON I w WHICH ARE IN A PATH OF TRAVEL, SHALL BE OPERABLE WITH A SINGLE <br /> 'n 3. LAVATORIES SHALL BE MOUNTED WITH A MINIMUM DISTANCE OF 15 <br /> DOORS AND GATES SHALL COMPLY WITH SECTION v '1' EFFORT BY LEVER TYPE HARDWARE, PANIC BARS, PUSH-PULL 6. GRAB BARS SHALL BE DESIGNED TO SUPPORTA 250 POUND <br /> INCHES (18 INCHES IN CALIFORNIA) FROM A WALL OR PARTITION TO <br /> X 7777-309.4. OPERABLE PARTS OF SUCH HARDWARE LATCHES AND LOCKSETS: PROVIDE LEVER TYPE, PUSH/PULL OR PANIC TYPE _ Z MOUNTING FLANGE COVER PLATE ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE THE CENTER OF THE FIXTURE. ACCESSIBLE LAVATORIES SHALL BE FORCE. <br /> a SHALL BE 34 INCHES 864 MM MINIMUM AND PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING Q <br /> HARDWARE CENTERED BETWEEN 34 INCHES TO 44 INCHES ABOVE FLOOR. CBC = m NTH VANDAL RESISTANT SET SCREWS MOUNTED WITH THE RIM OR COUNTER SURFACE NO HIGHER THAN 34 <br /> 44 INCHES (1118 MM) MAXIMUM ABOVE THE FINISH 11B-404.2.7. z o HARDWARE. INCHES ABOVE THE FLOOR. TELEPHONES (WHERE APPLICABLE) <br /> M FLOOR OR GROUND. WHERE SLIDING DOORS ARE IN CLEAR LEVEL FLOOR AREA <br /> THE FULLY OPEN POSITION, OPERATING HARDWARE MAXIMUN PRESSURE FOR OPENING DOORS: 1'-6" (SHOWN OUTLINED) FOR co 5. HAND ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED 1. PROVIDE A 30 INCH X 48 INCH CLEAR SPACE AT TELEPHONE. THE <br /> SHALL BE EXPOSED AND USABLE FROM BOTH SIDES. INTERIOR DOORS: 5 POUNDS. �i z EXTERIOR DOORS 1`0 BETWEEN 34 INCHES AND 44 INCHES MAXIMUM ABOVE THE FLOOR. IDENTIFICATION SYMBOLS (TOILET ROOM) CLEAR SPACE MAY INCLUDE KNEE SPACE UNDER THE TELEPHONE. '[� Q <br /> EXTERIOR DOORS: 5 POUNDS. INT DR o� BACKING PLATE 2013 CBC 11 B-404.2.7. 1. DOOR MOUNTED SIGNAGE G M <br /> DIRECTION OF SWING. PIVOT OR SIDE-HINGED FIRE DOORS: 15 POUNDS. 2'-0" 2. THE HIGHEST OPERABLE PART OF THE TELEPHONE SHALL BE WITHIN o <br /> DOOR SWINGING DOORS SHALL SWING IN THE ' ' TOILET TANK (WHERE APPLICABLE) 6. THE FLOOR OR LANDING LENGTH ON EACH SIDE OF AN ENTRANCE A. (MEN'S) - EQUILATERAL TRIANGLE 1/4" THICK WITH EDGES 48 INCHES OF THE FLOOR IF FORWARD APPROACHED AND 54 INCHES <br /> DIRECTION OF EGRESS TRAVEL WHERE ALL EXIT DOORS SHALL HAVE LOCKING HARDWARE THAT IS OPENABLE FROM THE EXTERIOR DOORS OR A PASSAGE DOOR SHALL BE LEVEL AND CLEAR AT LEAST 60 12" LONG AND A VERTEX POINTING UPWARD. IF SIDE APPROACHED. <br /> SERVING A ROOM OR AREA CONTAINING AN INSIDE WITHOUT A KEY, SPECIAL KNOWLEGE, OR EFFORT. INCHES IN THE DIRECTION OF THE DOOR SWING AND AT LEAST 48 <br /> OCCUPANT LOAD OF 50 OR MORE PERSONS, INCHES OPPOSITE THE DIRECTION OF THE DOOR SWING AS MEASURED B. (WOMEN'S) - 12" 0 CIRCLE 1/4" THICK. 3. TELEPHONES MOUNTED IN A CORNER THAT REQUIRE WHEELCHAIR <br /> PER CBC SEC. 1010.1.2.1. AT RIGHT ANGLES TO THE FACE OF THE DOOR IN THE CLOSED USERS TO REACH DIAGONALLY SHALL HAVE THE HIGHEST OPERABLE <br /> POSITION. THE WIDTH OF THE LEVEL AND CLEAR AREA ON THE SIDE C. (UNISEX) PART NO HIGHER THAN 54 INCHES ABOVE THE FLOOR. <br /> - 12" 0 CIRCLE 1/4" THICK WITH 1/4" THICK � � <br /> X ITNG DOORS, THRESTHOLD, CLEAR SPACE DETAILS <br /> SCALE: NONE GRAB BAR WHICH THE DOOR SWINGS SHALL EXTEND A MINIMUM OF 24 INCHES TRIANGLE SUPERIMPOSED WITHIN CIRCLE.PAST THE STRIKE EDGE OF THE DOOR FOR DOORS WITH LATCH SIDE 4. THE CORD FROM THE TELEPHONE TO THE HANDSET SHALL BE AT <br /> 3 5 <br /> SCALE: NONE APPROACH AND 36 INCHES FOR DOORS REQUIRING LATCH SIDE D. THE COLOR AND CONTRAST OF THE SIGN DISTINCTLY LEAST 29 INCHES LONG. <br /> APPROACH. REFER TO DETAIL NO. 3 ON THIS DRAWING FOR ADDITIONAL CONTRASTS WITH THE COLOR AND CONTRAST OF THE DOOR. <br /> CLEARANCE REQUIREMENTS. 5. IF BANKS OF PUBLIC TELEPHONES ARE PROVIDED, THEN A <br /> 0 EO EO 30 <br /> E. SIGNS ARE CENTERED ON THE DOOR 58" - 60" FROM THE REASONABLE NUMBER, BUT ALWAYS AT LEAST ONE, IN A BUILDING OR <br /> ,I 30 7. THE FLOOR OR LANDING SHALL NOT BE MORE THAN 1/2 INCH FLOOR. FACILITY SHALL BE EQUIPPED WITH A VOLUME CONTROL. <br /> LOWER THAN THE THRESHOLD OF THE DOORWAY. CHANGES IN LEVEL <br /> BETWEEN 1/4 INCH AND 1/2 INCH SHALL BE LEVELED WITH A SLOPE 2. WALL MOUNTED SIGNAGE 6. TELEPHONES SHALL HAVE PUSH-BUTTON CONTROLS WHERE SERVICE <br /> 4 1 24" NO GREATER THAN 1:2. A. THE INERNATIONAL SYMBOL AF ACCESSIBILITY IS INSTALLED ON FOR SUCH EQUIPMENT IS AVAILABLE. <br /> THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR. THE ADDITIONAL REQUIREMENTS <br /> 8. THE BOTTOM 10 INCHES OF ALL DOORS EXCEPT AUTOMATIC AND BORDER DIMENSIONS OF THIS PICTOGRAM SHALL BE MINIMUM OF <br /> SINK, 6 1/2" MAX. DEPTH SLIDING) SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE TO ALLOW 6" IN HEIGHT. WHERE THERE IS NO WALL SPACE ON THE LATCH <br /> / THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT SIDE, INCLUDING AT DOUBLE LEAF DOORS, SIGNS SHALL BE 1. THE CENTER OF RECEPTACLE OUTLETS SHALL BE NOT LESS THAN <br /> CREATING A TRAP OR HAZARDOUS CONDITION WHERE NARROW FRAME PLACED ON THE NEAREST ADJACENT WALL, PREFERABLY ON THE 15 INCHES ABOVE THE FLOOR OR WORKING PLATFORM. <br /> DOORS ARE USED, A 10 INCH. HIGH SMOOTH PANEL SHALL BE RIGHT. 2. ELECTRICAL SWITCHES. CONTROLS AND SWITCHES INTENDED TO BE USED <br /> INSTALLED ON THE PUSH SIDE OF THE DOOR WHICH WILL ALLOW THE BY THE OCCUPANT OF A ROOM OR AREA TO CONTROL LIGHTING AND Drawn <br /> By <br /> to max A. DANG <br /> 30 DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST. B. VERBAL DESCRIPTION AS TO RESTROOM USAGE (I.E. MEN'S RECEPTACLE OUTLETS, APPLIANCES OR COOLING, HEATING AND VENTILATING <br /> ' Side Reach r RESTROOM, ETC.) IS PLACED DIRECTLY BELOW THE SYMBOL OF EQUIPMENT, SHALL COMPLY WITH SECTION LLB-308 EXCEPT THE LOW REACH Checked By <br /> 10 max 9. THE MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 ACCESSIBILITY. SHALL BE MEASURED TO THE BOTTOM OF THE OUTLET BOX AND THE HIGH <br /> CLEAR FLOOR SPACE HIGH AND LOW SIDE HIGH FORWARD U-1 LBS. FOR ALL DOORS EXCEPT FIRE DOOR. SUCH PULL OR PUSH REACH SHALL BE MEASURED TO THE TOP OF THE OUTLET BOX. <br /> PARALLEL APPROACH REACH LIMITS REACH LIMIT h CnEFFORT BEING APPLIED AT RIGHT ANGLES TO HINGED DOORS AND AT C. THE CHARACTERS AND BACKGROUND OF THE SIGN IS Date <br /> -Y - WRAPPED PLUMBING 10-28-21 <br /> z THE CENTER PLANE OF SLIDING OR FOLDING DOORS. COMPENSATING EGGSHELL, MATTE, OR OTHER NON-GLARE FINISH AND THE 3. THE CENTER OF FIRE ALARM INITIATING DEVICES (BOXES) SHALL BE <br /> SIDE REACH SIDE REACH FORWARD REACH z ¢ DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET COLOR AND CONTRAST OF THE SIGN DISTINCLY CONTRASTS WITH LOCATED 48 INCHES ABOVE THE LEVEL OF THE ADJACENT FLOOR, scale <br /> Of X M THE ABOVE STANDARDS. WHEN FIRE DOORS ARE REQUIRED, THE THE COLOR AND CONTAST OF THE WALL. WORKING PLATFORM, GROUND SURFACE, OR SIDEWALK. INTERNATIONAL <br /> Q MAXIMUM EFFORT TO OPERATE THE DOOR MAY NOT EXCEED 15 LBS. SYMBOL OF ACCESSIBILITY SHALL BE THE STANDARD USED TO IDENTIFY <br /> J LU � M D. SIGNS ARE CENTERED ON THE WALL 48" TO 60" FROM THE FACILITIES THAT ARE ACCESSIBLE TO AND USABLE BY PHYSICALLY <br /> °b No, <br /> AS NOTED <br /> iv 10. DOOR CLOSER AND GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM AN FLOOR. DISABLED PERSONS. THE SYMBOL SPECIFIED ABOVE SHALL CONSIST OF <br /> KNEE CLEARANCE r- OPEN POSITION OF 90 DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO A A WHITE FIGURE ON BLUE BACKGROUND. THE BLUE SHALL BE EQUAL <br /> 1. CONTROLS & OPERATING MECHANISMS SHALL COMPLY WITH CBC CHAPTER 27" HIGH BY 30" WIDE `_ POSITION OF 12 DEGREES FROM THE LATCH IS 5 SECONDS MINIMUM. CBC SECTION E. LETTERS AND NUMERALS ARE RAISED 1/32", ARE SANS-SERIF TO COLOR N0. 15090 IN FEDERAL STANDARD 595A. <br /> 11 B. AND 19" MIN. DEEP 116-404.2.8.1. <br /> 2. ALL CONTROLS & OPERATING MECHANISMS WHICH ARE INTENDED FOR UPPERCASE CHARACTERS AND ARE ACCOMPANIED BY GRADE 2 <br /> - REMOVABLE CABINET DOOR BRAILLE CHARACTERS ARE MINIMUM ACCOMPANIED <br /> HIGH AND A MAXIMUM <br /> DETAIL PLAN <br /> NORMAL USE BY BUILDING OCCUPANTS SHALL BE PROVIDED WITH OF 2" HIGH. <br /> CBC-COMPLIANT CLEAR FLOOR SPACES & SHALL BE PLACED WITHIN 1" OF FINISHED FLOOR STAIRWAYS REQUIRED FORWARD O <br /> THE 34 1 TOILET ROOM FIXTURES AND ACCESSORIES <br /> PUBLIC RESTROOM D00R SIGNS FORWARDBAFSIDEDAPPROAAPPROACH REACH RANGES (48" A.F.F. _ <br /> CLEAR FLOOR SPACE: 1. STAIRWAYS SHALL HAVE HANDRAILS ON EACH SIDE. EVERY Drawing No. <br /> OF 17 INCHESS <br /> PROVIDE A CLEAR FLOOR SPACE AT LEAST 30" BY 48" IN FRONT OF A STAIRWAY REQUIRED TO BE MORE THAN 88 INCHES IN WIDTH SHALL BE 1. THE HEIGHTACCESSIBLE WATER CLOSETS SHALL U A MINIMUM <br /> SINK TO ALLOW FORWARD APPROACH. THE CLEAR FLOOR SPACE SHALL PROVIDED WITH NOT LESS THAN ONE INTERMEDIATE HANDRAIL FOR AND A MAXIMUM OF 19 INCHES MEASURED TO THE <br /> BE ON AN ACCESSIBLE ROUTE AND SHALL EXTEND A MAXIMUM 19" EACH 88 INCHES OF REQUIRED WIDTH. INTERMEDIATE HANDRAILS TOP OF THE TOILET SEAT. <br /> UNDERNEATH THE SINK. SHALL BE SPACED APPROXIMATELY EQUALLY WITHIN THE ENTIRE WIDTH 2 PROVIDE 17 TO 18 INCHES FROM THE CENTERLINE OF THE WATER <br /> SCALE: NOME <br /> RESTROOM DOOR SIGNS 8 REACH RANGES ACCESSIBLE SINK OF THE STAIRWAY. CLOSET TO THE ADJACENT WALL. A-200 <br /> SCALE: NONE 7 6 <br /> SCALE: NONE <br /> of Sheets <br />