Laserfiche WebLink
Pacific Gas and <br /> 4 Electric Company <br /> Attachment 2 — Electric Facilities <br /> It is PG & E ' s policy to permit certain uses on a case by case basis within its electric <br /> transmission fee strip ( s ) and /or easement ( s ) provided such uses and manner in which they are <br /> exercised , will not interfere with PG & E ' s rights or endanger its facilities . Some <br /> examples / restrictions are as follows : <br /> 1 . Buildings and Other Structures : No buildings or other structures including the foot print and <br /> eave of any buildings , swimming pools , wells or similar structures will be permitted within fee <br /> strip ( s ) and /or easement ( s ) areas . PG & E ' s transmission easement shall be designated on <br /> subdivision / parcel maps as " RESTRICTED USE AREA — NO BUILDING . " <br /> 2 . Grading : Cuts , trenches or excavations may not be made within 25 feet of our towers . <br /> Developers must submit grading plans and site development plans ( including geotechnical <br /> reports if applicable ) , signed and dated , for PG & E ' s review . PG & E engineers must review grade <br /> changes in the vicinity of our towers . No fills will be allowed which would impair grouncl4o - <br /> conductor clearances . Towers shall not be left on mounds without adequate road access to <br /> base of tower or structure . <br /> 3 . Fences : Walls , fences , and other structures must be installed at locations that do not affect <br /> the safe operation of PG & ' s facilities . Heavy equipment access to our facilities must be <br /> maintained at all times . Metal fences are to be grounded to PG & E specifications . No wall , fence <br /> or other like structure is to be installed within 10 feet of tower footings and unrestricted access <br /> must be maintained from a tower structure to the nearest street . Walls , fences and other <br /> structures proposed along or within the fee strip ( s ) and / or easement ( s ) will require PG & E <br /> review ; submit plans to PG & E Centralized Review Team for review and comment . <br /> 4 . Landscaping : Vegetation may be allowed ; subject to review of plans . On overhead electric <br /> transmission fee strip ( s ) and /or easement ( s ) , trees and shrubs are limited to those varieties that <br /> do not exceed 10 feet in height at maturity . PG & E must have access to its facilities at all times , <br /> including access by heavy equipment . No planting is to occur within the footprint of the tower <br /> legs . Greenbelts are encouraged . <br /> 5 . Reservoirs , Sumps , Drainage Basins , and Ponds : Prohibited within PG & E ' s fee strip ( s ) <br /> and /or easement ( s ) for electric transmission lines . <br /> 6 . Automobile Parking : Short term parking of movable passenger vehicles and light trucks <br /> ( pickups , vans , etc . ) is allowed . The lighting within these parking areas will need to be reviewed <br /> by PG & E ; approval will be on a case by case basis . Heavy equipment access to PG & E facilities <br /> is to be maintained at all times . Parking is to clear PG & E structures by at least 10 feet . <br /> Protection of PG & E facilities from vehicular traffic is to be provided at developer ' s expense AND <br /> to PG & E specifications . Blocked - up vehicles are not allowed . Carports , canopies , or awnings <br /> are not allowed . <br /> 7 . Storage of Flammable , Explosive or Corrosive Materials : There shall be no storage of fuel or <br /> combustibles and no fueling of vehicles within PG & E ' s easement . No trash bins or incinerators <br /> are allowed . <br /> PG & E Gas and Electric Facilities Page 5 <br /> Public <br />