Laserfiche WebLink
S A N J 0 A Q I I I Irl Environmental Health Department <br /> CCUNT <br /> Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> NLPI Carquest Escalon 1730 JACKSON AVE, ESCALON October 17, 2022 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 507 CCR 66265.195 Failed to conduct daily inspections of hazardous waste tank system and maintain records onsite. <br /> OBSERVATION: The facility has a hazardous waste tank but does not have three years of complete daily tank <br /> inspection records. The facility have a 1,000 gallon aboveground storage tank. No records was observed during the <br /> time of inspection. <br /> REGULATION GUIDANCE: <br /> (a)The owner or operator shall inspect,where present, at least once each operating day: <br /> (1)overfill/spill control equipment(e.g.,waste-feed cutoff systems, bypass systems, and drainage systems)to <br /> ensure that it is in good working order; <br /> (2)the aboveground portions of the tank system, if any, to detect corrosion or releases of waste; <br /> (3)data gathered from monitoring equipment and leak-detection equipment, (e.g., pressure and temperature <br /> gauges, monitoring wells)to ensure that the tank system is being operated according to its design; <br /> (4)the construction materials and the area immediately surrounding the externally accessible portion of the tank <br /> system including secondary containment structures(e.g., dikes)to detect erosion or signs of releases of hazardous <br /> waste (e.g.,wet spots, dead vegetation); and <br /> (5)for uncovered tanks,the level of waste in the tank, to ensure compliance with section 66265.194(b)(3). <br /> (c)The owner or operator shall document in the operating record of the facility an inspection of those items in <br /> subsection (a)of this section. <br /> CORRECTIVE ACTION: Immediately start conducting and documenting complete daily hazardous waste tank <br /> inspections. Provide a corrective action statement and supporting documentation to the San Joaquin County <br /> Environmental Health Department(EHD)within 30 days. <br /> This is a Class II violation. <br /> 605 CCR 66262.34(f) Failed to completely label containers or portable tanks of hazardous waste. <br /> OBSERVATION: Hazardous waste containers were observed on-site with incomplete labeling. The containers <br /> were: <br /> -One black 55 gallon drum on the south side of the storage area was observed with used oil filters without an <br /> accumulation start date. <br /> -Three black 55 gallon drums in front of the 1000 gallon used oil tank was observed without an accumulation start <br /> date. <br /> -One oil filter drained container in front of the 1000 gallon used oil tank was observed without an accumulation start <br /> date,the words"Hazardous Waste", name and address of generator, hazardous properties, physical state, and <br /> composition (contents). <br /> REGULATION GUIDANCE: All hazardous waste containers shall be marked with the following information: the <br /> words"Hazardous Waste", name and address of generator, hazardous properties, physical state, composition <br /> (contents), accumulation start date <br /> CORRECTIVE ACTION: Immediately label the containers as required for hazardous waste. Provide a corrective <br /> action statement and supporting documentation to the San Joaquin County Environmental Health Department <br /> (EHD)within 30 days. <br /> This is a minor violation. <br /> FA0009771 PR0546796 SCO01 10/17/2022 <br /> EHD 22-02 Rev.12/06/2021 Page 8 of 9 Large Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />