Laserfiche WebLink
XGENERAL NOTESX.X.X.XXXX'-XX"X.X.X.XXXXX.XXXXXXF.E.XXX-XXXABBREVIATIONSNOT ALL ABBREVIATIONS MAY BE USED IN THIS DOCUMENTGLAMGLAZED LAMINATEGBGRAB BARGDGRADE, (ING)GRNGRANITEGRTGRATE, (ING)GVLGRAVELGRHSGREENHOUSEGTGROUTGRDGUARDGUTGUTTERGPDWGYPSUM DRYWALLGPLGYPSUM LATHGPPLGYPSUM PLASTERGPTGYPSUM TILEGPWGYPSUM WALLBOARDHCHANDICAPHRLHANDRAILHBOHARDBOARDHDWHARDWAREHWDHARDWOODHDRHEADERHTGHEATINGHVACHEATING/VENTILATION/AIRCONDITIONINGHDHEAVY DUTYHTHEIGHTHPTHIGH POINTHCRHOLLOW COREHORHORIZONTALHBHOSE BIBBINCANINCANDESCENTINCININCINERATORINCLINCLUDE, (ED), (ING)IDINSIDE DIAMETERINSINSULATE, (ED), (ING)INSCINSULATING CONCRETEIGLINSULATING GLASSINTINTERIORINTMINTERMEDIATEINVINVERTJCJANITOR'S CLOSETJTJOINTJFJOINT FILLERJJOISTKPLKICKPLATEKITKITCHENKOKNOCKOUTLBLLABELLABLABORATORYLADLADDERLBLAG BOLTLAMLAMINATE, (ED)LGLLAMINATED GLASSLAVLAVATORYLOLAYOUTLHLEFT HANDLLENGTHLTLIGHTLWLIGHTWEIGHTLMSLIMESTONELTLLINTELLLLIVE LOADLOCLOCATELLDLOOSE LANDLVLOUVERLPTLOW POINTMBMACHINE BOLTMHMANHOLEMFRMANUFACTURE, (ER)MRBMARBLEMASMASONRYMTLMATERIALMAXMAXIMUMMECHMECHANIC, (AL)MCMEDICINE CABINETMEDMEDIUMMDOMEDIUM DENSITY OVERLAYMBRMEMBERMMBMEMBRANEMETMETALMMETER, (S)MWMICROWAVEMMMILLIMETER, (S)MINMINIMUMMRMGLMIRROR GLASS (FRAMED)MISCMISCELLANEOUSMODMODULARMLDMOLDING, MOULDINGMRMOP RECEPTORMSMOP SINKMTMOUNT, (ED), (ING)MOVMOVABLEMULLMULLIONNLNAILABLENATNATURALNINICKELNRNOISE REDUCTIONNOMNOMINALNNORTHPBPANIC BARPTDPAPER TOWEL DISPENSERPTRPAPER TOWEL RECEPTORPARPARALLELPRPTPARAPETPKPARKINGPBDPARTICLE BOARDPTNPARTITIONPVPAVE, (D), (ING)PVMTPAVEMENTPERFPERFORATE, (D)PERPERIMETERPEXPEX TUBINGPTRPLANTERPLTGPLANTINGPLASPLASTERPLAPLASTICPLAMPLASTIC LAMINATEPLPLATEPGPLATE GLASSPWDPLYWOODPTPOINTPVCPOLYVINYL CHLORIDEPEPORCELAIN ENAMELPCPLPORTLAND CEMENT PLASTERPDPOUND, (S)PCFPOUNDS PER CUBIC FOOTPLFPOUNDS PER LINEAR FOOTPSFPOUNDS PER SQUARE FOOTPSIPOUNDS PER SQUARE INCHPCCPRECAST CONCRETEPFBPREFABRICATE, (ED)PFNPREFINISHEDPRFPERFORATEDPREMPREMOLDEDPTPRESSURE TREATEDPLTPROPERTY LINEQTQUARRY TILERBTRABBET, REBATERADRADIUSRFTRAFTERRLRAIL, (ING)RECRECESS, (ED)REFREFER, (ENCE)RFLREFLECT, (ED), (IVE), (OR)REFRREFRIGERATORREGREGISTERRENREINFORCE, (ED), (ING)RECPREINFORCED CONCRETE PIPEREMREMOVE, (ABLE)REQ'DREQUIREDRESRESILIENTRETRETURNRARETURN AIRRVSREVERSE (SIDE)REVREVISE, (S), (ED)RHRIGHT HANDROWRIGHT OF WAYRRISERRVTRIVETR&SROD AND SHELFRDROOF DRAINRFHROOF HATCHRFGRMROOMROROUGH OPENINGRSROUGH SAWNRCPROUND CONCRETE PIPEROKROWLOCKRBRUBBER BASERBTRUBBER TILERBLRUBBER STONESFGLSAFETY GLASSSCHSCHEDULESCNSCREEN, (ED)SCUPSCUPPERSLNTSEALANTSTGSEATINGSECSECTIONSEI7-ELEVEN INC.SVYDSERVICE YARDSSKSERVICE SINKSHTHSHEATH, (ING)SHTSHEETSGSHEET GLASSSHSHELF, SHELVINGSHNGSHINGLE, (S)SHUSHUTTER, (S)SDGSIDINGSMSIMILARSKLSKYLIGHTSLSLEEVESLOSLOPESOLSOLDIERSCSOLID CORESPSOUNDPROOFSSOUTHSPCSPACE, (R)SGLSPANDREL GLASSSPKSPEAKERSPLSPECIALSPECSPECIFICATIONSPHSPLASHSQSQUARESFSQUARE FEETSSTSTAINLESS STEELSTGLSTAINED GLASSSTDSTANDARDSTASTATIONSTSTEELSTOSTORAGESDSTORM DRAINSTRSTRUCTURALSIPSSTRUCTURAL INSULATED PANELSTCOSTUCCOSFLRSUBFLOORSASUPPLY AIRSUSSUSPENDEDSYDSIDE YARDSYMSYMMETRY, (ETRICAL)SYNSYNTHETICSYSSYSTEMTKBDTACKBOARDTELTELEPHONETVTELEVISIONTTEMPERED GLASSTIGTEMPERED INSULATED GLASSTZTERRAZZOTHKTHICK, (NESS)THRTHRESHOLDTBRLTO BE RELOCATEDTOBRTO BE REMOVEDTPDTOILET PAPER DISPENSERTPTNTOILET PARTITIONTOLTOLERANCET&GTONGUE AND GROOVETSLTOP OF CONCRETE SLABTCTOP OF CURBTJTOP OF JOISTTPTOP OF PLATETSTTOP OF STEELTSFTOP OF SUBFLOORTWTOP OF WALLTPGTOPPINGTORTO REMAINTBTOWEL BARTRTRANSOMTSTUBE STEELTRNBTURNBUCKLETYPTYPICALUCUNDERCUTUNFUNFINISHEDUNOUNLESS NOTED OTHERWISEURURINALUTLUTILITYVJV-JOINTVBVAPOR BARRIERVARVARNISHVNRVENEERVERTVERTICALVGVERTICAL GRAINVNVINYLVBVINYL BASEVCTVINYL COMPOSITION TILEVFVINYL FABRICVTVINYL TILEVICPVITREOUS CLAY PIPEVICTVITREOUS CLAY TILEWSCTWAINSCOTWHWALL HUNGWCWATER CLOSETWHTRWATER HEATERWPWATERPROOFINGWRWATER RESISTANTWSWATERSTOPWSTWEATHERSTRIP, (ING)WWFWELDED WIRE FABRICWWESTWHSWHEEL STOPWHAWATER HAMMER ARRESTORWIDWIDTH, WIDEWINWINDOWWGWIRED GLASSWMWIRE MESHWOWITHOUTWDWOODWIWROUGHT IRONABANCHOR BOLTACPACOUSTICAL CEILING PANELACTACOUSTICAL CEILING TILEADHADHESIVEADJADJUSTABLEAFFABOVE FINISHED FLOORAFGABOVE FINISH GRADEAHUAIR HANDLING UNITALTALTERNATEALUMALUMINUMAPACCESS PANELAPCARCHITECTURAL PRECASTCONCRETEAHJAUTHORITY HAVINGJURISDICTIONBOBOTTOM OFBDBOARDBLDGBUILDINGBLKNGBLOCK (BLOCKING)B.M.BENCH MARKBOTBOTTOMBSMTBASEMENTCGCORNER GUARDCLCENTERLINECJCONTROL JOINTCICAST IRONCLGCEILINGCLRCLEARCMUCONCRETE MASONRY UNITCOCLEAN OUTCOLCOLUMNCONCCONCRETECONSTCONSTRUCTIONCONTCONTINUOUSCORRCORRIDORCPVCCHLORINATED POLYVINYLCHLORIDECSCOUNTERSUNKCTCERAMIC TILECVRCOVERDPDAMP PROOFINGDDDECK DRAINDEMODEMOLITIONDEPTDEPARTMENTDETDETAILDFDRINKING FOUNTAINDIADIAMETERDIAGDIAGONALDIMDIMENSIONDISPDISPENSERDLDEAD LOADDNDOWNDRDOORDSDOWNSPOUTDWGDRAWINGEEASTEAEACHECEXPOSED CONSTRUCTIONEIFSEXTERIOR INSULATIONFINISH SYSTEMEJEXPANSION JOINTELELEVATIONELECELECTRICALELEVELEVATOREMEREMERGENCYENCLENCLOSUREEQEQUALEQUIPEQUIPMENTETREXISTING TO REMAINEWCELECTRICAL WATER COOLEREWSEMERGENCY WASH STATIONEXHEXHAUSTEXISTEXISTINGEXPEXPANSIONEXTEXTERIORFOCFACE OF CONCRETEFOFFACE OF FINISHFOMFACE OF MASONRYFOSFACE OF STUDSFASFASTEN,FASTENERFNFENCEFBDFIBERBOARDFGLFIBERGLASSFINFINISH (ED)FFEFINISHED FLOOR ELEVATIONFFLFINISHED FLOOR LINEFAFIRE ALARMFEFIRE EXTINGUISHERFECFIRE EXTINGUISHER CABINETFHSFIRE HOSE STATIONFPLFIREPLACEFPFIREPROOFFRTFIRE-RETARDANTFXTFIXTUREFLGFLASHINGFLXFLEXIBLEFGFLOAT GLASSFLRFLOOR (ING)FDFLOOR DRAINFLFLOW LINEFLURFLOURESCENTFJTFLUSH JOINTFTGFOOTINGFNDFOUNDATIONFRFRAME (D), (ING)FSFULL SIZEFURFURRED, (ING)FUTFUTUREFWFILTERED WATER* GENERAL NOTES APPLY TO ALL CONSTRUCTION DOCUMENTS.- DOOR TAG- ENLARGED DETAIL INDICATOR- GRID LINE INDICATOR- WINDOW TAG- WALL TAG- HEIGHT ELEVATION INDICATOR- NORTH ARROW- SPOT ELEVATION INDICATOR- EQUIPMENT TAG- KEY NOTE INDICATOR- SECTION CUT INDICATOR- ELEVATION INDICATOR- REVISION DELTA- ROOM TAG- KEY NOTE INDICATOR- FINISH INDICATORREFERENCE SYMBOLSXXXXXXXXXXXXXXX000AXX.XX'-XX"- FIREEXTINGUISHERA. GENERAL1. ALL CONTRACTORS AND SUBCONTRACTORS WILL THOROUGHLY FAMILIARIZETHEMSELVES WITH THESE CONSTRUCTION DOCUMENTS AND WILL VERIFYEXISTING SITE AND CONDITIONS PRIOR TO SUBMITTING A BID. ALLSUBCONTRACTORS WILL PROVIDE ALL LABOR, SUPERVISION, AND MATERIALS ASREQUIRED. ALL WORK TO BE PERFORMED IN A GOOD AND WORKMANLIKE MANNERACCORDING TO THE TRUE INTENT AND MEANING OF THE DRAWINGS ANDSPECIFICATIONS.2.THIS ARCHITECT AND HIS PROFESSIONAL CONSULTANTS WILL NOT HAVE CONTROLOF AND WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS,TECHNIQUES, SEQUENCES, PROCEDURES OR SAFETY PRECAUTIONS ANDPROGRAMS IN CONNECTION WITH THE WORK ON THIS PROJECT OR FOR THE ACTSOR OMISSIONS OF THE CONTRACTOR, SUBCONTRACTOR OR ANY OTHER PERSONSPERFORMING ANY OF THE WORK ON THIS SITE, NOR FOR THE FAILURE OF ANY OFTHEM TO CARRY OUT THE WORK IN ACCORDANCE WITH THE INTENT OF THECONTRACT AND CONSTRUCTION DOCUMENTS.3.ALL CONTRACTORS WILL PROVIDE ADEQUATE BRACING AND SHORING TO ENSURESTRUCTURAL STABILITY OF THE BUILDING AND ALL RELATED BUILDINGCOMPONENTS, IE: STRUCTURAL WALLS, INTERIOR WALL ASSEMBLIES, ETC. DURINGTHE CONSTRUCTION PHASE OF THIS PROJECT.4.WORK WILL BE COORDINATED WITH ALL TRADES IN ORDER TO AVOIDINTERFERENCE, AND AVOID OMISSIONS.5.ALL MATERIALS USED WILL BE NEW AND BEAR U.L. LABELS WHERE REQUIRED ANDMEET APPROPRIATE N.E.M.A. STANDARDS.6.LAYOUT ALL PARTITIONS BEFORE BEGINNING CONSTRUCTION TOPREVENTERRORS BY DISCREPANCY. ALL DRYWALL PARTITIONSWILL BE INSTALLED ASNOTED ON THE DRAWINGS.7.EACH SUBCONTRACTOR WILL AMEND AND MAKE GOOD AT HIS OWN COST, ANYDEFECTS OR OTHER FAULTS IN HIS WORKMANSHIP AND/OR HIS SUPPLIEDMATERIALS.8.ALL CONTRACTORS WILL GUARANTEE ALL LABOR AND CONTRACTOR PROVIDEDMATERIALS FOR A PERIOD OF 1 YEAR FROM DATE OF OCCUPANCY.9.VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO ORDERING, CUTTING AND/ORINSTALLING MATERIAL, PRODUCT OR EQUIPMENT. IN THE EVENT OF ANYDISCREPANCIES, CONTACT THE CONSTRUCTION PROJECT MANAGER BEFOREPROCEEDING WITH THAT WORK.10.ALL SUBCONTRACTORS WILL PROVIDE A CERTIFICATE OF INSURANCE TO THEGENERAL CONTRACTOR PRIOR TO STARTING ANY WORK ON THIS PROJECT.CERTIFICATE OF INSURANCE CANNOT BE TERMINATED OR CANCELED W/O 10 DAYSPRIOR WRITTEN NOTICE TO THE CONSTRUCTION PROJECT MANAGER.11.ANY ADDITIONS OR CHANGES TO WORK MUST BE AUTHORIZED IN WRITING BY THEARCHITECT OR ENGINEER OF RECORD. NO ALTERATIONS WILL BE MADE ON THISPROJECT EXCEPT UPON WRITTEN ORDER BY THE ARCHITECT OR ENGINEER OFRECORD.12.NO SUBSTITUTIONS OF ANY KIND FOR MATERIALS SPECIFIED ON THESECONSTRUCTION DOCUMENTS IS ALLOWED. NO "EQUIVALENT" SUBSTITUTIONS WILLBE MADE, UNLESS DUE TO THE LACK OF AVAILABILITY OF THE ORIGINAL MATERIALSPECIFIED AND APPROVED IN WRITING BY THE CONSTRUCTION PROJECTMANAGER AND THE ARCHITECT OR ENGINEER OF RECORD13.WEATHER CONDITIONS: CONTRACTORS WILL PROTECT ALL PARTS OF THEIRWORK FROM WEATHER DAMAGE DUE TO FROST, RAIN, HEAT, ETC. AND WILL MAKEGOOD TO THE SATISFACTION OF THE CONSTRUCTION PROJECT MANAGER ANDGENERAL CONTRACTOR ANY PORTION OF THE WORK WHICH MAY HAVE BECOMEDAMAGED.14.RESPONSIBILITY OF CONTRACTORS: EACH SUBCONTRACTOR AND THE GENERALCONTRACTOR ARE RESPONSIBLE FOR WORKMANSHIP AND MATERIALS. EACHSUBCONTRACTOR AND THE GENERAL CONTRACTOR ARE RESPONSIBLE FOR THECARE AND PROTECTION OF HIS OWN WORK AND MATERIALS.15.SITE SAFETY: EACH CONTRACTOR WILL ABIDE BY LOCAL AREA STANDARDS ANDRELATED OSHA STANDARDS FOR THE PROTECTION AND SAFETY FOR THEIREMPLOYEES ON SITE. THIS ARCHITECT AND HIS PROFESSIONAL CONSULTANTSWILL BE HELD HARMLESS BY THE OWNER, GENERAL CONTRACTOR AND RELATEDAWARDED TRADES ON THIS PROJECT FOR ACCIDENTS OR INJURIES CAUSED ORACCRUED ON THIS PROPERTY DURING THE PRE/ACTUAL/POST CONSTRUCTIONPHASES OF THIS PROJECT.16.LIENS: ALL SUBCONTRACTORS AND THE GENERAL CONTRACTOR WILL DELIVER TOTHE CONSTRUCTION PROJECT MANAGER, A COMPLETE RELEASE OF ALL CLAIMSARISING OUT OF THIS CONTRACT.17.PILFERAGE: EACH CONTRACTOR WILL BE RESPONSIBLE FOR HIS OWN EQUIPMENTAND MATERIALS USED IN CONSTRUC TION INCLUDING THOSE ITEMS FURNISHED BY7-ELEVEN, INC. AND DELIVERED TO THE JOB SITE, TO BE INSTALLED BY THECONTRACTOR. 7-ELEVEN, INC. WILL NOT BE HELD LIABLE FOR STOLEN EQUIPMENT,MATERIALS OR DAMAGE OF THE SAME ON THIS JOB SITE.18.GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR REMOVAL OF DEBRISACCUMULATED BY EACH TRADE. HOWEVER, EACH TRADE WILL KEEP THE JOB SITECLEAN AND SAFE AT ALL TIMES, ALONG WITH A BROOM FINISH AT THE END OFEACH WORKING DAY.19.SCHEDULE OF WORK: THE CONSTRUCTION PROJECT MANAGER WILL STATE TOTHE GENERAL CONTRACTOR DURING THE BIDDING PROCESS, THE REQUIREDNUMBER OF CALENDAR DAYS TO COMPLETE THIS WORK.20.REFER TO STRUCTURAL, MECHANICAL, ELECTRICAL AND PLUMBING DWGS FORADDITIONAL GENERAL NOTES, ABBREVIATIONS AND SYMBOLS.21.MATERIALS & SYSTEMS NOTES ARE TYPICAL IN NATURE AND APPLY TO MULTIPLEDRAWINGS. NOTES ON ANY ONE DRAWING ARE TO APPLY TO ALL OTHER SIMILARMATERIALS & SYSTEMS UNLESS NOTED OTHERWISE. THE GENERAL NOTES APPLYTO ALL THE CONSTRUCTION DOCUMENTS.22.ELEVATIONS REFERENCED ON ARCHITECTURAL DRAWINGS ARE TOP OF SLABLEVELS UNLESS NOTED OTHERWISE.23.GENERAL CONTRACTOR TO COORDINATE FLOOR AND WALL PENETRA- TIONS WITHTHE CONSTRUCTION PROJECT MANAGER, INCLUDING BUT NOT LIMITED TOMECHANICAL, ELECTRICAL AND PLUMBING.24. FOR THE PURPOSE OF THESE DRAWINGS AND SPECIFICATIONS, THE TERM "BY7-ELEVEN" SHALL MEAN ITEM PROVIDED BY 7- ELEVEN, INC. AND INSTALLED BYCONTRACTOR AS PART OF THE WORK OF THIS CONTRACT. THE TERM "NOT INCONTRACT" (NIC) SHALL MEAN ITEM PROVIDED AND INSTALLED BY 7-ELEVEN, INC.UNDER SEPARATE CONTRACT.25.GENERAL CONTRACTOR TO COORDINATE WITH THE CONSTRUCTION PROJECTMANAGER FOR ALL ROOF PATCHWORK, REPAIR, AND/OR REPLACEMENT.B. DIMENSIONS1.ALL DIMENSIONS ARE IN FEET-INCHES UNLESS NOTED OTHERWISE.2.DIMENSIONS GOVERN. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS IN THEFIELD BEFORE PROCEEDING WITH THE WORK. NOTIFY THE ARCHITECT OFRECORD OF ANY DISCREPANCIES.3.EXTERIOR WALLS ARE DIMENSIONED TO THE EXTERIOR FACE OF METAL STUDPANEL, CMU BLOCK, OR STRUCTURAL SHEATHING UNLESS NOTED OTHERWISE.4.INTERIOR WALLS AND PARTITIONS ARE DIMENSIONED TO FINISHED FACE UNLESSNOTED OTHERWISE.5.DOORS ARE LOCATED BY THEIR JAMB RELATIVE TO ADJACENT WALLS ANDPARTITIONS. DOOR OPENINGS ARE DIMENSIONED TO THE STRIKE OR HINGE FACEOF THE DOOR FRAMES. ALL INTERIOR DOORS AT 6" FROM PARTITION WALLUNLESS NOTED OTHERWISEC. MICELLANEOUS1.SEAL EXTERIOR JOINTS AROUND DOORS, WINDOWS AND LOUVER FRAMES AND ATPENETRATIONS OF MECHANICAL, ELECTRICAL AND PLUMBING ELEMENTS TOPREVENT AIR AND WATER LEAKAGE.2.ISOLATE DISSIMILAR METALS EFFECTIVELY FROM EACH OTHER TO PREVENTELECTROLYTIC ACTION.3.PROVIDE ACCESS PANELS AS REQUIRED FOR MECHANICAL AND PLUMBINGVALVES.HEALTH DEPT. NOTES1.A CONCRETE SLAB IS PROVIDED FOR TRASH, GARBAGE, AND GREASECONTAINER. IF WALLS ENCLOSE AREA, THE INTERIOR WALL SURFACES WILL BESMOOTH, SEALED AND WASHABLE (E.G., PLASTERED SMOOTH AND PAINTED,ETC.).2.THE FACILITY UTILIZES SINGLE-USE OR MULTI-USE FOOD AND BEVERAGEUTENSILS. ALL FOOD-RELATED AND UTENSIL-RELATED EQUIPMENT SHALL MEETOR BE EQUIVALENT TO SANITATION STANDARDS ESTABLISHED BY AN AMERICANNATIONAL STANDARDS INSTITUTE (ANSI) ACCREDITED PROGRAM.3.ALL FLOOR MTD EQUIPMENT WILL BE INSTALLED ON MINIMUM 6" SANITARY LEGS,CASTORS, OR COMPLETELY SEALED IN POSITION ON A 4 " HIGH CURB W/CONTINUOUSLY COVED BASE. COUNTERTOP EQUIPMENT WILL BE ON 4-INCHSANITARY LEGS OR SEALED TO THE COUNTER UNLESS READILY MOVABLE.4.IF SOFT DRINK, ICE OR OTHER DISPENSERS ARE SELF-SERVICE, OR IF REFILLSARE PROVIDED THEY MUST BE PUSH BUTTON TYPES, OR LEVER TYPES WHERETHE LEVER CONTACTS THE CONTAINER AT LEAST ONE INCH BELOW THE RIM.5.ANY OPENABLE WINDOWS VENT OPENINGS OR OTHER SIMILAR OPENINGS MUSTBE PROVIDED WITH TIGHT FITTING SCREENS OF MINIMUM 16-MESH TO THE INCH.WINDOWS TO BE FIXED AT FOOD PREP, UTENSIL-WASHING, OPEN FOOD ANDUTENSIL STORAGE AREAS.6.ALL EXTERIOR DOORS OPEN OUTWARD & ARE SELF-CLOSING AND TIGHTFITTING.7.BI-FOLD, FRENCH, ACCORDION STYLE & ROLL-UP DOORS CANNOT OPEN INTOTHE FOOD PREP, UTENSIL WASHING OR UNPACKAGED FOOD SERVICE AREAS.8.TOILET RM. & DRESSING RM. DOORS MUST BE SELF-CLOSING, TIGHT FITTING.9.DELIVERY DOORS SHALL BE EQUIPPED WITH A MICROSWITCH ACTIVATED AIRCURTAIN DEVICE THAT DELIVERS AND AIR VELOCITY OF AT LEAST 750 FPM,MEASURED 3 FEET ABOVE THE FLOOR. THE CURTAIN OF AIR SHALL COVER THEENTIRE WIDTH OF THE DOOR. FOR DELIVERY DOORS THAT ARE WIDER THAN 4FEET, THE AIR CURTAIN MUST PRODUCE AN AIR VELOCITY OF AT LEAST 1600FPM, AS MEASURED 3 FEET ABOVE THE FLOOR.10.A MINIMUM OF 10 FOOT-CANDLES OF LIGHT MEASURED 30" OFF FLOOR ISPROVIDED IN WALK-IN REFRIGERATED STORAGE AND DRY STORAGE ROOMSAND AT LEAST 20-FOOT CANDLES IS PROVIDED WHERE FOOD IS PROVIDED FORCONSUMER SELF-SERVICE, WHERE FRESH PRODUCE OR PREPACKAGED FOODSARE SOLD OR OFFERED FOR CONSUMPTION; INSIDE EQUIPMENT SUCH ASREACH-IN AND UNDER-COUNTER REFRIGERATORS; IN AREAS USED FORHANDWASHING, WAREWASHING, EQUIPMENT AND UTENSIL STORAGE, AND INTOILET ROOMS.11.A MIN. OF 50 FOOT-CANDLES OF LIGHT MEASURED 30" A.F.F. IS PROVIDED WHENWORKING W/ FOOD OR WORKING W/ UTENSILS OR EQUIPMENT SUCH AS KNIVES,SLICERS, GRINDERS, OR SAWS WHERE EMPLOYEE SAFETY IS A FACTOR AND INALL AREAS DURING PERIODS OF CLEANING.12.SHATTERSHIELDS FOR ALL LIGHTS ABOVE FOOD PREPARATION, WORK, ANDSTORAGE AREAS WILL BE PROVIDED.13.ALL WAREWASHING SINKS TO HAVE 3 COMPARTMENTS THAT ARE A MINIMUMSIZE OF AT LEAST 18"X18"X12" DEEP (OR 16"X20"X12" DEEP) WITH A MINIMUM 18"DRAINBOARD AT EACH END. IF AGAINST A WALL, IT MUST HAVE AN 8" INTEGRALBACKSPLASH. HOWEVER, IT MUST BE CAPABLE OF ACCOMMODATING THELARGEST UTENSIL TO BE WASHED. A WAREWASHING MACHINE DOES NOTSUBSTITUTE FOR THE SINK REQUIREMENT.14.SINKS TO HAVE SPOUT(S) CAPABLE OF REACHING EACH COMPARTMENT.15.FOOD PREP SINK COMPARTMENT(S) TO BE AT LEAST 18"X18"X12" DEEP (OR16"X20"X12" DEEP) WITH A MINIMUM 18" DRAINBOARD. SEPARATE FOOD PREPSINKS TO BE PROVIDED FOR MEATS AND PRODUCE.16.THE 3 OR 4 COMPARTMENT BAR SINK TO BE AT LEAST 12"X12"X10" DEEP (OR10"X14"X10" DEEP) WITH A MINIMUM 18" DRAINBOARD AT EACH END.17.A SEPARATE WET WASTE DUMP FIXTURE SHALL BE PROVIDED FOR DISPOSAL OFDRINK OR WASTE ICE OR COFFEE WASTE.18.EACH HANDWASHING SINK MUST HAVE PERMANENTLY MOUNTEDSINGLE-SERVICESOAP AND PAPER TOWEL DISPENSERS.19.THE HW HEATER WILL BE A COMMERCIAL TYPE CAPABLE OF CONSTANTLYSUPPLYING HOT WATER @ A TEMPERATURE OF 120ºF TO ALL 1IN SIZING THEWATER HEATER, THE PEAK HOURLY DEMAND FOR ALL SINKS, ETC., ARE ADDEDTOGETHER TO DETERMINE THE MIN. REQUIRED RECOVERY RATE.20.ALL LAVATORIES OR HAND SINKS WILL HAVE A COMBINATION FAUCET ORPREMIXING FAUCET CAPABLE OF SUPPLYING WATER TEMPERED TO 100ºF.SELF-CLOSING OR METERED FAUCET TO PROVIDE AT LEAST 15 SECONDS OFWATER WITHOUT REACTIVATION.21.ALL PLUMB'G, ELECTRIC'L AND GAS LINES SHALL BE CONCEALED W/IN THEBUILDING STRUCTURE TO AS GREAT AN EXTENT AS POSSIBLE. ALL EXPOSEDCONDUITS, PLUMBING, ETC. SHALL BE INSTALLED AT LEAST 6" OFF FLOOR AND3/4" FROM WALLS USING STANDOFF BRACKETS.22.CONDUITS, PLUMBING OR PIPING CANNOT BE INSTALLED ACROSS ANY AISLEWAY, TRAFFIC AREA OR DOOR OPENING.23.MULTIPLE RUNS OR CLUSTERS OF CONDUIT OR PIPELINES SHALL BE FURRED INOR ENCASED IN AN APPROVED SEALED ENCLOSURE.24.ALL LIQUID WASTE SHALL BE DRAINED BY MEANS OF INDIRECT WASTE PIPESINTO A FLOOR SINK. FLOOR SINKS ARE TO BE INSTALLED FLUSH WITH THEFINISHED FLOOR SURFACE AND HAVE SUITABLE EASILY REMOVABLE SAFETYCOVER GRATES.25.FLOOR SINK TO BE 50% EXPOSED WHEN NO ACCESS IS PROVIDED FORCLEANING OR BE IN LINE WITH THE FRONT FACE OF ELEVATED FREESTANDINGEQUIPMENT.26.APPROVED BACKFLOW PREVENTION DEVICES SHALL BE PROPERLY INSTALLEDUPSTREAM OF ANY POTENTIAL HAZARD BETWEEN THE POTABLE WATER SUPPLYAND A SOURCE OF CONTAMINATION. HOSES SHALL NOT BE ATTACHED TO AFAUCET OR HOSE BIBB UNLESS AN APPROVED BACKFLOW PREVENTER ISPROVIDED.27.WATER SUPPLY TO CARBONATORS SHALL BE PROTECTED BY AN APPROVED REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER. THERELIEF VALVE SHALL DRAIN INDIRECTLY TO SEWER WITH A LEGAL AIR GAP.28.FOR CLEANING FLOOR MATS, THE JANITORIAL SINK TO BE A MINIMUM 24" BY 36"FLOOR-MOUNTED TYPE. MOPS SHALL BE PLACED IN A POSITION THAT ALLOWSTHEM TO AIR-DRY W/O SOILING WALLS, EQUIPMENT, OR SUPPLIES.29.THE JANITORIAL SINK FAUCET WILL HAVE A THREADED OUTER LIP FOR HOSEATTACHMENT AND AN APPROVED BACKFLOW PREVENTION DEVICE. NOCHEMICAL DISPENSING SYSTEMS OR SHUTOFF VALVES TO BE ATTACHED TOMOP SINK FAUCET OUTLET (UNLESS A "SIDEKICK" PLUMBING DEVICE ISINSTALLED).30.NO CONDENSATE OR WASTEWATER INCLUDING HVAC WILL DRAIN INTO THEJANITORIAL SINK.31.CONCRETE FLOOR ARE TO BE SEALED W/ A USDA OR FDA FOOD GRADEAPPROVED PENETRATING SEALER THAT IS NONABSORBENT AND ACIDRESISTANT . GREASE TRAP TO BE LOCATED OUTSIDE THE FOOD SERVICEACTIVITY AREA, FLUSH WITH THE FINISHED FLOOR WHEN INDOORS. LOCALWASTEWATER DISTRICT OR BUILDING DEPARTMENT TO BE CONTACTED FORGREASE REMOVAL REQUIREMENTS.32.FLOOR DRAINS SHALL BE INSTALLED IN FLOORS THAT ARE WATER- FLUSHEDFOR CLEANING AND IN AREAS WHERE PRESSURE SPRAY METHODS FOR CLEANING EQUIPMENT ARE USED, IN RESTROOMS, JANITORIAL ROOMS, SCULLERIES, AND AT BARS WITH WAREWASHING. FLOOR SURFACES IN AREAS PURSUANT TO THIS SHALL BE SLOPED 1:50 TO THE FLOOR DRAINS.33.ADEQUATE VENTILATION IS TO BE PROVIDED TO ALL TOILET ROOMS, JANITORCLOSETS WITH MOP SINKS, AND INDOOR TRASH ROOMS AND IN DRESSING/CHANGE ROOM(S).34.THE FLOOR FINISH WILL HAVE A SMOOTH SURFACE UNDER ALL EQUIPMENT ANDWALKWAYS WILL HAVE A LIGHT TEXTURE ONLY.35.THE PAINT USED ON WALLS AND CEILINGS OF ALL KITCHEN, FOOD PREPARATION, WORK, AND STORAGE AREAS WILL BE A GLOSS OR SEMI-GLOSS ENAMEL. FINISH MATERIAL SHALL BE A LIGHT COLOR IN FOOD PREPAREAS FOR EASY CLEANING.GAGAGE, GAUGEGVGALVANIZEDGKTGASKET, (ED)GCGENERAL CONTRACT, (OR)GLGLASS, GLAZINGGLBGLASS BLOCKGCMUGLAZED CONCRETEMASONRY UNITSNNICNOT IN CONTRACTNTSNOT TO SCALENONUMBEROCON CENTER, (S)OPOPAQUEOPGOPENINGOPHOPPOSITE HANDORNORNAMENTALODOUTSIDE DIAMETEROAOVERALLOHOPPOSITE HANDPNTPAINT, (ED)PNLPANEL, (ING)1.LOCATIONS AND CLASSIFICATIONS OF EXTINGUISHERS SHALL BE INACCORDANCE WITH CFC 906 AND CALIFORNIA CODE OF REGULATIONS (CCR),TITLE 19.2.DURING CONSTRUCTION, AT LEAST ONE EXTINGUISHER SHALL BE PROVIDEDON EACH FLOOR LEVEL AT EACH STAIRWAY, IN ALL STORAGE ANDCONSTRUCTION SHEDS, IN LOCATIONS WHERE FLAMMABLE OR COMBUSTIBLELIQUIDS ARE STORED OR USED, AND WHERE OTHER SPECIAL HAZARDS AREPRESENT PER CFC SECTION 3315.13.IN BUILDINGS THAT REQUIRE STAND PIPES, STANDPIPES SHALL BE PROVIDEDDURING CONSTRUCTION WHEN THE HEIGHT REACHES 40 FT ABOVE THELOWEST LEVEL OF FIRE DEPARTMENT VEHICLE ACCESS. A FIRE DEPARTMENTCONNECTION SHALL BE NO MORE THAN 100 FEET FROM AVAILABLE FIREDEPARTMENT VEHICLE ACCESS ROADWAYS. CFC SECTIONS 33, 3313.4.BUILDINGS UNDERGOING CONSTRUCTION, ALTERATION OR DEMOLITION SHALLCONFORM TO CFC CHAPTER 33. WELDING, CUTTING OR OTHER HOT WORKSHALL BE IN CONFORMANCE WITH CFC CHAPTER 35.5.ADDRESS IDENTIFICATION SHALL BE PROVIDED FOR ALL NEW AND EXISTINGBUILDINGS IN A LOCATION THAT IS PLAINLY VISIBLE AND LEGIBLE FROM THESTREET OR ROAD FRONTING THE PROPERTY. WHERE ACCESS IS BY WAY OFA PRIVATE ROAD AND THE BUILDING ADDRESS CANNOT BE VIEWED FROM THEPUBLIC RIGHT OF WAY, AN APPROVED SIGN OR MEANS SHALL BE USED TOIDENTIFY THE STRUCTURE. PREMISES IDENTIFICATION SHALL CONFORM TOCBC SECTION 501.26.WALL, FLOOR AND CEILING FINISHES AND MATERIALS SHALL NOT EXCEED THEINTERIOR FINISH CLASSIFICATION IN CBC TABLE 803.9 AND SHALL MEET THEFLAME PROPAGATION PERFORMANCE CRITERIA OF THE CALIFORNIA CODE OFREGULATIONS, TITLE 19, DIVISION 1. DECORATIVE MATERIALS SHALL BEPROPERLY TREATED BY A PRODUCT OR PROCESS APPROVED BY THE STATEFIRE MARSHALL WITH APPROPRIATE DOCUMENTATION PROVIDED TO THE CITYOF MANTECA.7.DUMPSTERS AND TRASH CONTAINERS EXCEEDING 1.5 CUBIC YARDS SHALLNOT BE STORED IN BUILDINGS OR PLACED WITH 5 FEET OF COMBUSTIBLEWALLS, OPENINGS OR COMBUSTIBLE ROOF EAVE LINES UNLESS PROTECTEDBY AN APPROVED SPRINKLER SYSTEM OR LOCATED IN A TYPE I OR IIASTRUCTURE SEPARATED BY 10 FEET FROM OTHER STRUCTURES.CONTAINERS LARGER THAN 1 CUBIC YARD SHALL BE IN A NON ORLIMITED-COMBUSTIBLE MATERIALS OR SIMILARLY PROTECTED OR SEPARATEDCFC 308.EXISTS, EXIT SIGNS, FIRE ALARM PANELS, HOSE CABINETS, FIREEXTINGUISHER LOCATIONS AND STANDPIPE CONNECTIONS SHALL NOT BECONCEALED BY CURTAINS, MIRRORS, OR OTHER DECORATIVE MATERIAL.9.OPEN FLAMES, FIRE, AND BURNING ON ALL MREMISES IS PROHIBITED EXCEPTAS SPECIFICALLY PERMITTED BY THE COUNTY OF MANTECA AND CFC 308.10.THE EGRESS PATH SHALL REMAIN FREE AND CLEAR OF ALL OBSTRUCTIONS ATALL TIMES . NO STORAGE IS PERMITTED IN ANY EGRESS PATHS.11.KEYED REMOTE TEST SWITCHES WITH LED LIGHT INDICATORS TO BEPROVIDED ON THE WALL NO GREATER THAN 6 FT. FOR ALL DUCT SMOKEDETECTORS.FIRE DEPARTMENT NOTES36.PRIOR TO INSTALLATION, SAMPLES OF FINISHES TO BE SUBMITTED TO ENVIRONMENTAL HEALTH FOR APPROVAL AS NEEDED.37. COLD STORAGE ROOMS SHALL BE PROVIDED WITH A SECTION OF SHELVINGINSTALLED TO HOLD SHALLOW COOL DOWN PANS -NOT TO EXCEED 4" IN HEIGHT. SPACE BETWEEN SHELVING TO BE AT LEAST 8" HIGH.38. BACKUP DRY STORAGE SHELVING SHALL BE A MINIMUM OF 96 LINEAR FEET(MEASURED WITH TIERS) OR 25% OF KITCHEN, FOOD PREP, AND WORK AREAS,WHICHEVER IS GREATER. SHELVING SHALL BE AT LEAST 18 INCHES DEEP ANDSTART A MINIMUM SIX INCHES OFF THE FLOOR SURFACE.39. SHELVING OVER WET AREAS (SINKS, MOP SINKS ETC.) AND FOOD PREPSURFACES WILL BE METAL.40. ALL SEAMS, GAPS, OPENINGS TO BE PROPERLY SEALED.41.SNEEZEGUARDS ARE SUBJECT TO FIELD INSPECTION AND APPROVAL.42FOOD ON DISPLAY SHALL BE PROTECTED FROM CONTAMINATION BY THE USE OFPACKAGING, COUNTER, SERVICE LINE, OR SNEEZE GUARDS THAT INTERCEPT ADIRECT LINE BETWEEN THE CUSTOMER'S MOUTH AND THE FOOD BEINGDISPLAYED.ADDITIONAL INFORMATIONTHIS PROJECT IS SERVED BY CITY OF MANTECA (WATER / SEWER) TOTAL NUMBER OF EMPLOYEES PER SHIFT - 3A1.0GENERAL NOTES, ABBREVIATIONS AND <br />SYMBOLS LEGEND <br />3883 Ruffin Road Suite B <br />San Diego, CA 92123 <br />p: 714/560/8200 <br />f: 714/560/8211 <br />www.tait.com <br />Since 1964 Los Angeles <br />Anaheim <br />Ontario <br />Sacramento <br />San Diego <br />Boise <br />Dallas <br />Denver <br />Seattle <br />‹"TAIT & ASSOCIATES" 2020 ALL RIGHTS RESERVED <br />Job#: <br />Scale: <br />Date: <br />Drawn By: <br />Checked By: <br />Rev. #Date DescriptionSHEET:7-ELEVEN, INC. <br />3200 HACKBERRY, IRVING, TEXAS 75063 <br />SE1237 <br />7-ELEVEN 1046249 <br />1110 N. MAIN ST <br />MANTECA, CA 95336 <br />TICOFALCC 1 9 0 9 1L <br />11 / 21EXPIRESETSTAFOIA <br />NR SNI <br />C <br />E <br />EDCHRAIETA <br />EN <br />FR <br />JR.EK <br />ALLPNSI