CORRIDORS & AISLESTHE TERM CORRIDOR SHALL INCLUDE EXTERIOR EXIT BALCONIES ANDANY COVERED OR ENCLOSED EXIT PASSAGEWAY, INCLUDINGWALKWAYS, TUNNELS AND MALLS. PARTITIONS, RAILS, COUNTERS, ANDOTHER SIMILAR SPACE DIVIDERS NOT OVER 5'-9" IN HEIGHT ABOVE THEFLOOR SHALL NOT BE CONSTRUED TO FORM CORRIDORS.1.EVERY CORRIDOR SERVING AN OCCUPANT LOAD OF 10 OR MORESHALL NOT BE LESS THAN 44" IN WIDTH.2.CORRIDORS SERVING AN OCCUPANT LOAD OF LESS THAN 10 SHALLNOT BE LESS THAN 36" IN WIDTH.3.CIRCULATION AISLES AND PEDESTRIAN WAYS SHALL BE SIZEDACCORDING TO FUNCTIONAL REQUIREMENTS AND IN NO CASE SHALLBE LESS THAN 36" IN CLEAR WIDTH.4.EVERY AISLE SHALL BE NOT LESS THAN 36" WIDE IF SERVING ONLYONE SIDE AND NOT LESS THAN 42" WIDE IF SERVING BOTH SIDES.FLOORS & LEVELSNOTE: LEVEL AREA IS DEFINED AS "A SPECIFIED SURFACE THAT DOES NOTHAVE A SLOPE IN ANY DIRECTION EXCEEDING 1/4 INCH IN ONE FOOT FROMTHE HORIZONTAL (2.083% GRADIENT)".1.IN BUILDINGS AND FACILITIES, FLOORS OF A GIVEN STORY SHALL BEA COMMON LEVEL THROUGHOUT, OR SHALL BE CONNECTED BYPEDESTRIAN RAMPS, PASSENGER ELEVATORS, OR SPECIAL ACCESSLIFTS.2.GROUND AND FLOOR SURFACES ALONG ACCESSIBLE ROUTES AND INACCESSIBLE ROOMS AND SPACES, INCLUDING FLOORS, WALKS,RAMPS, STAIRS, AND CURB RAMPS, SHALL BE STABLE, FIRM, ANDSLIP-RESISTANT.3.CHANGES IN LEVEL UP TO 1/4" MAY BE VERTICAL AND WITHOUT EDGETREATMENT.4.CHANGES IN LEVEL BETWEEN 1/4" AND 1/2" SHALL BE ACCOMPLISHEDBY MEANS OF A RAMP NO STEEPER THAN 1 VERTICAL TO 2HORIZONTAL.5.CHANGES IN LEVEL GREATER THAN 1/2" SHALL BE ACCOMPLISHED BYMEANS OF A RAMP.6.IF CARPET OR CARPET TILE IS USED ON A GROUND OR FLOORSURFACE, IT SHALL BE SECURELY ATTACHED; HAVE A FIRM CUSHION,PAD OR BACKING OR NO CUSHION OR PAD; AND HAVE A LEVEL LOOP,TEXTURED LOOP, LEVEL CUT PILE, OR LEVEL CUT/UNCUT PILETEXTURE. THE MAXIMUM PILE HEIGHT SHALL BE 1/2". EXPOSEDEDGES OF CARPET SHALL BE FASTENED TO FLOOR SURFACES ANDHAVE TRIM ALONG THE ENTIRE LENGTH OF THE EXPOSED EDGE.CARPET EDGE TRIM SHALL COMPLY WITH CODE.SANITARY FACILITIES (GENERAL)1.SANITARY FACILITIES THAT SERVE BUILDINGS, FACILITIES ORPORTIONS OF BUILDINGS OR FACILITIES THAT ARE REQUIRED TO BEACCESSIBLE TO PERSONS WITH DISABILITIES ARE REQUIRED TO BEACCESSIBLE.2.WHERE SEPARATE FACILITIES ARE PROVIDED FOR NON-DISABLEDPERSONS OF EACH SEX, SEPARATE FACILITIES SHALL BE PROVIDEDFOR PERSONS WITH DISABILITIES OF EACH SEX ALSO. WHEREUNISEX FACILITIES ARE PROVIDED FOR PERSONS WITHOUTDISABILITIES, AT LEAST ONE UNISEX FACILITY SHALL BE PROVIDEDPERSONS WITH DISABILITIES WITHIN CLOSE PROXIMITY TO THENON-ACCESSIBLE FACILITY.SINGLE ACCOMMODATION SANITARY FACILITIESNOTE: SINGLE ACCOMMODATION SANITARY FACILITY IS DEFINED AS "AROOM THAT HAS NOT MORE THAN ONE OF EACH TYPE OF SANITARYFIXTURE, IS INTENDED FOR USE BY ONLY ONE PERSON AT A TIME, HAS NOPARTITION AROUND THE TOILET, AND HAS A DOOR THAT CAN BE LOCKED ONTHE INSIDE BY THE ROOM OCCUPANT".1.THERE SHALL BE SUFFICIENT SPACE IN THE TOILET ROOM FOR AWHEELCHAIR MEASURING 30" WIDE BY 48" LONG TO ENTER THEROOM AND PERMIT THE DOOR TO CLOSE.2.THERE SHALL BE IN THE ROOM A CLEAR FLOOR SPACE OF AT LEAST60" IN DIAMETER, OR A T-SHAPED SPACE OR (B). NO DOOR SHALLENCROACH INTO THIS SPACE FOR MORE THAN 12" EXCEPT FOR THEPANEL DOOR TO ANY WATER CLOSET COMPARTMENT IF THERE ISONE.3.THE WATER CLOSET SHALL BE LOCATED IN A SPACE WHICHPROVIDES A MINIMUM 28" WIDE CLEAR SPACE FROM A FIXTURE OR AMINIMUM 32" WIDE CLEAR SPACE FROM A WALL AT ONE SIDE. THEOTHER SIDE SHALL PROVIDE 18" FROM THE CENTERLINE OF THEWATER CLOSET TO THE WALL. A MINIMUM 48" CLEAR SPACE SHALLBE PROVIDED IN FRONT OF THE WATER CLOSET.4.ALL DOORS, FIXTURES AND CONTROLS SHALL BE ON AN ACCESSIBLEROUTE WITH A MINIMUM CLEAR WIDTH OF 36" EXCEPT AT DOORS. IFA PERSON IN A WHEELCHAIR MUST MAKE A TURN AROUND ANOBSTRUCTION, THE MINIMUM CLEAR WIDTH OF THE ACCESSIBLEROUTE SHALL BE PER CODE.PASSENGER DROP-OFF & LOADING ZONES1.WHEN PROVIDED, PASSENGER DROP-OFF AND LOADING ZONESSHALL BE LOCATED ON AN ACCESSIBLE ROUTE OF TRAVEL.2.WHERE PROVIDED, ONE PASSENGER DROP-OFF AND LOADING ZONESHALL PROVIDE AN ACCESS AISLE AT LEAST 60" WIDE AND 20' LONGADJACENT AND PARALLEL TO THE VEHICLE PULL-UP SPACE. SUCHZONES SHALL BE LOCATED ON A SURFACE WITH A SLOPE NOTEXCEEDING 1 VERTICAL IN 50 HORIZONTAL. IF THERE ARE CURBSBETWEEN THE ACCESS AISLE AND THE VEHICLE PULL-UP SPACE,THEN A CURB RAMP SHALL BE PROVIDED.3.PROVIDE MINIMUM VERTICAL CLEARANCE OF 9'-6" AT ACCESSIBLEPASSENGER LOADING ZONES AND ALONG AT LEAST ONE VEHICLEACCESS ROUTE TO SUCH AREAS FROM SITE ENTRANCES AND EXITS.4.VALET PARKING FACILITIES SHALL PROVIDE A PASSENGER LOADINGZONE AND SHALL BE LOCATED ON AN ACCESSIBLE ROUTE TO THEENTRANCE OF THE FACILITY.PEDESTRIAN GRADE SEPARATIONS1.PEDESTRIAN RAMPS ON PEDESTRIAN GRADE SEPARATIONS SHALLCOMPLY WITH THE REQUIREMENTS FOR RAMPS.2.WHERE PEDESTRIAN GRADE SEPARATIONS CROSS STREETS OROTHER VEHICULAR TRAFFIC WAYS, AND WHERE A STREET LEVELCROSSING CAN REASONABLY AND SAFELY BE USED BY PERSONSWITH DISABILITIES, THERE SHALL BE PROVIDED CONFORMING CURBRAMPS AND A USABLE PATHWAY.3.CROSS SLOPES OF WALKING SURFACES SHALL BE THE MINIMUMPOSSIBLE AND SHALL NOT EXCEED 1/4" PER FOOT. THE SLOPE OFANY APPRECIABLY WARPED WALKING SURFACE SHALL NOT EXCEED1 VERTICAL IN 12 HORIZONTAL IN ANY DIRECTION.ELECTRICAL1.THE CENTER OF JUNCTION BOXES FOR RECEPTACLE OUTLETSSHALL BE INSTALLED AT AN ACCESSIBLE LOCATION MEETING THECLEARANCES AND REACH RANGE REQUIREMENTS OF BUILDINGCODE.2.THE CENTER OF THE GRIP OF THE OPERATING HANDLE OFCONTROLS OR SWITCHES INTENDED TO BE USED BY THE OCCUPANTOF THE ROOM OR AREA TO CONTROL LIGHTING AND RECEPTACLEOUTLETS, APPLIANCES, OR COOLING, HEATING, AND VENTILATINGEQUIPMENT SHALL MEET THE REQUIREMENTS OF BUILDING CODE.3.THE CENTER OF FIRE ALARM INITIATING DEVICES (BOXES) SHALL BELOCATED 48" ABOVE THE LEVEL OF THE FLOOR, WORKINGPLATFORM, GROUND SURFACE, OR SIDEWALK.4.THE INSTALLATION OF FIRE ALARM EQUIPMENT AND SYSTEMS IN ANYOCCUPANCY WITHIN THE SCOPE OF THESE REGULATIONS SHALL BEIN ACCORDANCE WITH THE PROVISIONS OF THE ELECTRICAL CODE.MULTIPLE ACCOMMODATION SANITARY FACILITIESNOTE: MULTIPLE ACCOMMODATION SANITARY FACILITY IS DEFINED AS "AROOM THAT HAS MORE THAN ONE SANITARY FIXTURE, IS INTENDED FORTHE USE OF MORE THAN ONE PERSON AT A TIME, AND WHICH USUALLY ISPROVIDED WITH PRIVACY COMPARTMENTS OR SCREENS SHIELDING SOMEFIXTURES FROM VIEW".1.A CLEAR SPACE MEASURED FROM THE FLOOR TO A HEIGHT OF 27"ABOVE THE FLOOR, WITHIN THE SANITARY FACILITY ROOM, OFSUFFICIENT SIZE TO INSCRIBE A CIRCLE WITH A DIAMETER NOT LESSTHAN 60", OR A CLEAR SPACE 56" BY 63" IN SIZE, SHALL BE PROVIDEDFOR WHEELCHAIR MANEUVERING. DOORS OTHER THAN DOOR TOTHE ACCESSIBLE TOILET COMPARTMENT IN ANY POSITION MAYENCROACH THE INTO THIS SPACE BY NOT MORE THAN 12".2.DOORS SHALL NOT SWING INTO THE FLOOR SPACE REQUIRED FORANY FIXTURE.3.A WATER CLOSET FIXTURE LOCATED IN A COMPARTMENT SHALLPROVIDE A MINIMUM 28" WIDE CLEAR SPACE FROM A FIXTURE OR AMINIMUM 32" WIDE CLEAR SPACE FROM A WALL AT ONE SIDE OF THEWATER CLOSET. THE OTHER SIDE OF THE WATER CLOSET SHALLPROVIDE 18" FROM THE CENTERLINE OF THE WATER CLOSET TO THEWALL. GRAB BARS SHALL NOT PROJECT MORE THAN 3" INTO THESECLEAR SPACES.4.A MINIMUM 48" LONG CLEAR SPACE SHALL BE PROVIDED IN FRONTOF THE WATER CLOSET IF THE COMPARTMENT HAS AN END OPENINGDOOR (FACING THE WATER CLOSET) AND A MINIMUM 60" LONGCLEAR SPACE SHALL BE PROVIDED IN FRONT OF THE WATER CLOSETIF THE COMPARTMENT HAS A DOOR LOCATED AT THE SIDE. GRABBARS SHALL NOT PROJECT MORE THAT 3" INTO THESE CLEARSPACES.PEDESTRIAN GRADE SEPARATIONS1.PEDESTRIAN RAMPS ON PEDESTRIAN GRADE SEPARATIONS SHALLCOMPLY WITH THE REQUIREMENTS FOR RAMPS.2.WHERE PEDESTRIAN GRADE SEPARATIONS CROSS STREETS OROTHER VEHICULAR TRAFFIC WAYS, AND WHERE A STREET LEVELCROSSING CAN REASONABLY AND SAFELY BE USED BY PERSONSWITH DISABILITIES, THERE SHALL BE PROVIDED CONFORMING CURBRAMPS AND A USABLE PATHWAY.3.CROSS SLOPES OF WALKING SURFACES SHALL BE THE MINIMUMPOSSIBLE AND SHALL NOT EXCEED 1/4" PER FOOT. THE SLOPE OFANY APPRECIABLY WARPED WALKING SURFACE SHALL NOT EXCEED1 VERTICAL IN 12 HORIZONTAL IN ANY DIRECTION.4.ALL LAVATORIES THAT ARE DESIGNATED TO BE ACCESSIBLE SHALLBE MOUNTED WITH THE RIM OR COUNTER EDGE NO HIGHER THAN 34"ABOVE THE FINISHED FLOOR AND WITH A VERTICAL CLEARANCEMEASURED FROM THE BOTTOM OF THE APRON OR OUTSIDE BOTTOMEDGE OF THE LAVATORY OF 29", REDUCING TO 27" AT A POINTLOCATED 8" BACK FROM THE FRONT EDGE. KNEE CLEARANCEBELOW THE LAVATORY SHALL EXTEND A MINIMUM OF 30" IN WIDTHBY 17" IN DEPTH. TOE CLEARANCE SHALL BE THE SAME WIDTH ANDSHALL BE A MINIMUM OF 9" HIGH FROM THE FLOOR AND A MINIMUMOF 17" DEEP FROM THE FRONT OF THE LAVATORY.5.HOT WATER AND DRAIN PIPES ACCESSIBLE UNDER LAVATORIESSHALL BE INSULATED OR OTHERWISE COVERED. THERE SHALL BENO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES.6.WHERE URINALS ARE PROVIDED, AT LEAST ONE SHALL HAVE ACLEAR FLOOR SPACE 30" BY 48" IN FRONT OF THE URINAL TO ALLOWFORWARD APPROACH.7.URINALS SHALL BE FLOOR MOUNTED OR WALL HUNG. WHERE ONEOR MORE WALL HUNG URINALS ARE PROVIDED, AT LEAST ONE WITHA RIM PROJECTING A MINIMUM OF 14" FROM THE WALL AND AT AMAXIMUM OF 17" ABOVE THE FLOOR SHALL BE PROVIDED.8.CONTROLS FOR WATER CLOSET FLUSH VALVES SHALL BE MOUNTEDON THE WIDE SIDE OF TOILET AREAS.9.WATER CLOSET AND URINAL FLUSH VALVE CONTROLS, AND FAUCETAND OPERATING MECHANISM CONTROLS, SHALL BE OPERABLE WITHONE HAND, SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, ORTWISTING OF THE WRIST, AND SHALL BE MOUNTED NO MORE THAN44" ABOVE THE FLOOR.10.THE FORCE REQUIRED TO ACTIVATE WATER CLOSET AND URINALFLUSH VALVE CONTROLS, AND FAUCET AND OPERATING MECHANISMCONTROLS, SHALL BE NO GREATER THAN 5 LBF. ELECTRONIC ORAUTOMATIC FLUSHING CONTROLS ARE ACCEPTABLE ANDPREFERABLE.11.SELF-CLOSING FAUCET CONTROL VALVES ARE ALLOWED IF THEFAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS.12.MIRRORS SHALL BE MOUNTED WITH THE BOTTOM EDGE NO HIGHERTHAN 40" FROM THE FLOOR.13.WHERE TOWEL, SANITARY NAPKINS, WASTE RECEPTACLES, ANDOTHER SIMILAR DISPENSING AND DISPOSAL FIXTURES AREPROVIDED, AT LEAST ONE OF EACH TYPE SHALL BE LOCATED WITHALL OPERABLE PARTS, INCLUDING COIN SLOTS, WITHIN 40" FROMTHE FINISHED FLOOR.14.TOILET TISSUE DISPENSERS SHALL BE LOCATED ON THE WALLWITHIN 12" OF THE FRONT EDGE OF THE TOILET SEAT AND NOLOWER THAN 19" FROM THE FLOOR. DISPENSERS THAT CONTROLDELIVERY OR THAT DO NOT PERMIT CONTINUOUS PAPER FLOWSHALL NOT BE USED.15.TOILET ROOM FLOORS SHALL HAVE A SMOOTH, HARD,NON-ABSORBENT SURFACE SUCH AS PORTLAND CEMENT,CONCRETE, CERAMIC TILE OR OTHER APPROVED MATERIAL WHICHEXTENDS UPWARD ONTO THE WALLS AT LEAST 5". WALLS WITHINWATER CLOSET COMPARTMENTS AND WALLS WITHIN 24" OF THEFRONT AND SIDES OF URINALS SHALL BE SIMILARLY FINISHED TO AHEIGHT OF 48" AND, EXCEPT FOR STRUCTURAL ELEMENTS, THEMATERIALS USED IN SUCH WALLS SHALL BE A TYPE WHICH IS NOTADVERSELY AFFECTED BY MOISTURE.DINING, BANQUET, & BAR FACILITIES1.EACH AREA WHERE A DIFFERENT TYPE OF FUNCTIONAL ACTIVITYOCCURS SHALL BE ACCESSIBLE TO PERSONS WITH DISABILITIES.PROVIDE WHEELCHAIR ACCESS TO BANQUET ROOMS.2.PROVIDE SEATS/SPACES FOR PEOPLE USING WHEELCHAIRS (ATLEAST ONE FOR EACH 20 SEATS, WITH AT LEAST ONE PERFUNCTIONAL AREA) INTEGRATED WITH GENERAL SEATING TO AVOIDHAVING ONE AREA SPECIFICALLY HIGHLIGHTED AS THE AREA FORPERSONS WITH DISABILITIES.3.ACCESS TO DISABLED SEATING SHALL BE PROVIDED WITH MAINAISLES NOT LESS THAN 36" IN CLEAR WIDTH.4.FOOD SERVICE AISLES SHALL BE A MINIMUM OF 36" IN CLEAR WIDTHWITH A PREFERRED WIDTH OF 42" WHERE PASSAGE OF STOPPEDWHEELCHAIRS BY PEDESTRIANS IS DESIRED. TRAY SLIDES SHALL BEMOUNTED NO HIGHER THAN 34" ABOVE THE FLOOR. IF SELF-SERVICESHELVES ARE PROVIDED, A REASONABLE PORTION MUST BE WITHIN34" OF THE FLOOR.5.TABLEWARE, DISHWARE, CONDIMENTS, AND FOOD AND BEVERAGEDISPLAY AND DISPENSING DEVICES, WHEN LOCATED ON TABLES ORCOUNTER TOPS, SHALL BE PLACED 28" TO 34" ABOVE THE ADJACENTFLOOR. THESE ITEMS, WHEN LOCATED ON SHELVES, SHALL BEPLACED NO HIGHER THAN 54" ABOVE THE ADJACENT FLOOR, WHERENOT REQUIRED TO REACH OVER AN OBSTRUCTION, AND NO HIGHERTHAN 46" ABOVE THE ADJACENT FLOOR WHEN REQUIRED TO REACHOVER AN OBSTRUCTION. AN OBSTRUCTION WHICH A DISABLEDPERSON IS REQUIRED TO REACH OVER SHALL BE NO HIGHER THAN34" ABOVE THE ADJACENT FLOOR WITH A HORIZONTAL REACH OVERTHE OBSTRUCTION OF NO MORE THAN 24".6.ACCESS TO FOOD PREPARATION AREAS SHALL COMPLY WITH THEPROVISIONS FOR ENTRANCE DOORS, DOORWAYS, AND AISLES.GRAB BARS1.GRAB BARS SHALL BE LOCATED ON EACH SIDE, OR ON ONE SIDE ANDTHE BACK OF THE ACCESSIBLE TOILET STALL OR COMPARTMENT.2.GRAB BARS AT THE SIDE SHALL BE AT LEAST 42" LONG WITH THEFRONT END POSITIONED 24" IN FRONT OF THE WATER CLOSETSTOOL AND WITH THE BACK END POSITIONED NO MORE THAN 12"FROM THE REAR WALL. GRAB BARS AT THE BACK SHALL BE NOTLESS THAN 36" LONG.3.GRAB BARS SHALL BE SECURELY ATTACHED 33" ABOVE ANDPARALLEL TO THE FLOOR, EXCEPT THAT WHERE A TANK-TYPETOILET IS USED WHICH OBSTRUCTS PLACEMENT AT 33", THE GRABBAR MAY BE AS HIGH AS 36".4.THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A GRABBAR SHALL BE 1-1/4" TO 1-1/2" OR THE SHAPE SHALL PROVIDE ANEQUIVALENT GRIPPING SURFACE. IF GRAB BARS ARE MOUNTEDADJACENT TO A WALL, THE SPACE BETWEEN THE WALL AND THEGRAB BARS SHALL BE 1-1/2".5.THE STRUCTURAL STRENGTH OF GRAB BARS, TUB AND SHOWERSEATS, FASTENERS, AND MOUNTING DEVICES SHALL MEET THEFOLLOWING SPECIFICATIONS:5.1.BENDING STRESS IN A GRAB BAR OR SEAT INDUCED BY THEMAXIMUM BENDING MOMENT FROM THE APPLICATION OF A 250-LBPOINT LOAD SHALL BE LESS THAN THE ALLOWABLE STRESS FORTHE MATERIAL OF THE GRAB BAR OR SEAT.5.2.SHEAR STRESS INDUCED IN A GRAB BAR OR SEAT BY THEAPPLICATION OF A 250-LB POINT LOAD SHALL BE LESS THAN THEALLOWABLE SHEAR STRESS FOR THE MATERIAL OF THE GRAB BAROR SEAT, AND ITS MOUNTING BRACKET OR OTHER SUPPORT ISCONSIDERED TO BE FULLY RESTRAINED, THEN DIRECT ANDTORSIONAL SHEAR STRESSES SHALL NOT EXCEED THE ALLOWABLESHEAR STRESS.5.3.SHEAR FORCE INDUCED IN FASTENER OR MOUNTING DEVICESFROM THE APPLICATION OF A 250-LB POINT LOAD SHALL BE LESSTHAN THE ALLOWABLE LATERAL LOAD OF EITHER THE FASTENEROR MOUNTING DEVICE OR THE SUPPORTING STRUCTURE,WHICHEVER HAS THE SMALLER ALLOWABLE LOAD.5.4.TENSILE FORCE INDUCED IN A FASTENER BY A DIRECT TENSIONFORCE OF A 250-LB POINT LOAD, PLUS THE MAXIMUM MOMENTFROM THE APPLICATION OF A 250-LB POINT LOAD, SHALL BE LESSTHAN THE ALLOWABLE WITHDRAWAL LOAD BETWEEN THEFASTENER AND SUPPORTING STRUCTURE.5.5.GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS.6.A GRAB BAR AND ANY WALL OR OTHER SURFACE ADJACENT TO ITSHALL BE FREE OF ANY SHARP OR ABRASIVE ELEMENTS. EDGESSHALL HAVE A MINIMUM RADIUS OF 1/8".CONTROLS & OPERATING MECHANISMS & ELECTRICAL1.CONTROLS AND OPERATING MECHANISMS REQUIRED TO BEACCESSIBLE. REFER TO CODE.2.CLEAR FLOOR SPACE THAT ALLOWS A FORWARD OR PARALLELAPPROACH BY A PERSON USING A WHEELCHAIR SHALL BE PROVIDEDAT CONTROLS, DISPENSERS, RECEPTACLES, AND OTHER OPERABLEEQUIPMENT.3.THE HIGHEST OPERABLE PART OF ALL CONTROLS, DISPENSERS,RECEPTACLES, AND OTHER OPERABLE EQUIPMENT SHALL BEPLACED WITHIN 48" OF THE FLOOR BUT NOT LOWER THAN 15" IFFORWARD APPROACHED AND WITHIN 54" BUT NOT LOWER THAN 9" IFSIDE APPROACHED.LOCKERS1.AT LEAST ONE AND NOT LESS THAN 1 % OF ALL LOCKERS SHALL BEMADE ACCESSIBLE TO PERSONS WITH DISABILITIES, INCLUDINGCLEAR SPACE, REACH RANGE REQUIREMENTS, AND A PATH OFTRAVEL NOT LESS THAN 36" IN CLEAR WIDTH TO THESE LOCKERS.FIXED OR BUILT-IN SEATING1.WHERE FIXED OR BUILT-IN SEATING, TABLES, OR COUNTERS AREPROVIDED FOR THE PUBLIC, AND IN GENERAL EMPLOYEE AREAS, 5%,BUT NEVER LESS THAN 1 MUST BE ACCESSIBLE.2.THE TOPS OF TABLES AND COUNTERS SHALL BE 28" TO 34" FROMTHE FLOOR OR GROUND.3.IF SEATING FOR PEOPLE IN WHEELCHAIRS IS PROVIDED AT FIXEDTABLES OR COUNTERS, KNEE SPACES AT LEAST 27" HIGH, 30" WIDE,AND 19" DEEP SHALL BE PROVIDED.4.IF SEATING SPACES FOR PEOPLE IN WHEELCHAIRS ARE PROVIDEDAT FIXED TABLES OR COUNTERS, CLEAR FLOOR SPACE SHALL BEPROVIDED. SUCH CLEAR FLOOR SPACE SHALL NOT OVERLAP KNEESPACE BY MORE THAN 19".5.WHERE A SINGLE COUNTER CONTAINS MORE THAN ONETRANSACTION STATION, SUCH AS (BUT NOT LIMITED TO) A BANKCOUNTER WITH MULTIPLE TELLER WINDOWS OR A RETAIL SALESCOUNTER WITH MULTIPLE CASH REGISTER STATIONS, AT LEAST 5%,BUT NEVER LESS THAN 1, OF EACH TYPE OF STATION SHALL BELOCATED AT A SECTION OF COUNTER THAT IS AT LEAST 36" LONGAND NO MORE THAN 28" TO 34" HIGH.ENTRANCES & EXITSNOTE 1: EXITS IN EXCESS OF THOSE REQUIRED BY CODE AND WHICH AREMORE THAN 24" ABOVE GRADE ARE NOT REQUIRED TO BE ACCESSIBLE.SUCH DOORS SHALL HAVE SIGNS WARNING THAT THEY ARE NOTACCESSIBLE. WARNING SIGNS SHALL COMPLY WITH BUILDING CODE.NOTE 2: FOR THE PURPOSES OF ADA, THE USE OF THE TERM EXIT DOORAPPLIES TO ALL DOORS THAT PROVIDE ACCESS, THAT IS, ENTRANCES,PASSAGE1.ALL ENTRANCES AND ALL EXTERIOR GROUND FLOOR EXIT DOORS TOBUILDINGS AND FACILITIES SHALL BE MADE ACCESSIBLE TOPERSONS WITH DISABILITIES.2.REVOLVING DOORS SHALL NOT BE USED AS A REQUIRED ENTRANCEFOR PERSONS WITH DISABILITIES.3.DURING PERIODS OF PARTIAL OR RESTRICTED USE OF A BUILDINGOR FACILITY, THE ENTRANCES USED FOR PRIMARY ACCESS SHALLBE ACCESSIBLE TO AND USABLE BY PERSONS WITH DISABILITIES.4.EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THEUSE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT.5.BARS,GRILLES, GRATES,OR SIMILAR DEVICES PLATED OVER DOORS,SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL, OR ANY SPECIAL KNOWLEDGE OR EFFORT. SUCH BARS,GRILLES, GRATES, OR SIMILAR DEVICES SHALL BE EQUIPPED WITHAN APPROVED RELEASE DEVICE FOR USE BY THE FIRE DEPARTMENTONLY ON THE EXTERIOR SIDE FOR THE PURPOSE OF FIREDEPARTMENT EMERGENCY ACCESS, WHEN REQUIRED BY THEAUTHORITY HAVING JURISDICTION.6.MANUALLY OPERATED EDGE- OR SURFACE-MOUNTED FLUSH BOLTSAND SURFACE BOLTS ARE PROHIBITED. WHEN EXIT DOORS AREUSED IN PAIRS AND APPROVED AUTOMATIC FLUSH BOLTS ARE USED,THE DOOR LEAF HAVING THE AUTOMATIC FLUSH BOLTS SHALL HAVENO DOORKNOB OR HARDWARE. THE UNLATCHING OF ANY LEAFSHALL NOT REQUIRE MORE THAN ONE SURFACE-MOUNTEDOPERATION.ASSEMBLY OCCUPANCIES1.ASSEMBLY AREAS WITH AUDIO-AMPLICATION SYSTEMS SHALL HAVEA LISTENING SYSTEM COMPLYING WITH ADA 4.33 TO ASSIST AREASONABLE NUMBER OF PEOPLE, BUT NO FEWER THAN TWO, WITHSEVERE HEARING LOSS. FOR ASSEMBLY AREAS WITHOUTAMPLIFICATION SYSTEMS AND FOR SPACES USED PRIMARILY ASMEETING AND CONFERENCE ROOMS, A PERMANENCY INSTALLED ORPORTABLE LISTENING SYSTEM SHALL BE PROVIDED. IF PORTABLESYSTEMS ARE USED FOR CONFERENCE OR MEETING ROOMS, THESYSTEM MAY SERVE MORE THAN ONE ROOM.RAMPSNOTE: ANY PATH OF TRAVEL SHALL BE CONSIDERED A RAMP IF ITS SLOPE ISGREATER THAN 1' RISE IN 20' OF HORIZONTAL RUN.1.THE MAXIMUM SLOPE OF A RAMP THAT SERVES ANY EXITWAY,PROVIDES ACCESS FOR PERSONS WITH DISABILITIES, OR IS IN THEPATH OF TRAVEL SHALL BE 1' RISE IN 12' OF HORIZONTAL RUN.2.THE CROSS SLOPE OF RAMP SURFACES SHALL BE NO GREATERTHAN 1:50.3.THE WIDTH OF RAMPS SHALL BE AS REQUIRED FOR STAIRWAYS ANDEXITS.4.PEDESTRIAN RAMPS SERVING PRIMARY ENTRANCES TO BUILDINGSHAVING AN OCCUPANT LOAD OF 300 OR MORE SHALL HAVE AMINIMUM CLEAR WIDTH OF 60".5.RAMPS SERVING GROUP R OCCUPANCIES MAY BE 36" CLEAR WIDTHWHEN THE OCCUPANT LOAD IS 50 OR LESS.6.ALL OTHER PEDESTRIAN RAMPS SERVING PRIMARY ENTRANCESSHALL HAVE A MINIMUM CLEAR WIDTH OF 48".7.LANDINGS SHALL BE PROVIDED AT THE TOP AND BOTTOM OF EACHRAMP.8.INTERMEDIATE LANDINGS SHALL BE PROVIDED AT INTERVALS NOTEXCEEDING 30" OF VERTICAL RISE AND AT EACH CHANGE OFDIRECTION.9.TOP LANDINGS SHALL BE NOT LESS THAN 60" WIDE AND SHALL HAVEA LENGTH OF NOT LESS THAN 60" IN THE DIRECTION OF RAMP RUN.10.DOORS IN ANY POSITION SHALL NOT REDUCE THE MINIMUMDIMENSION OF THE RAMP LANDING TO LESS THAN 42" AND SHALLNOT REDUCE THE REQUIRED WIDTH BY MORE THAN 3" WHEN FULLYOPEN.11.THE WIDTH OF THE LANDING SHALL EXTEND 24" PAST THE STRIKEEDGE OF ANY DOOR OR GATE FOR EXTERIOR RAMPS AND 18" PASTTHE STRIKE EDGE FOR INTERIOR RAMPS.12.AT BOTTOM AND INTERMEDIATE LANDINGS, THE WIDTH SHALL BE ATLEAST THE SAME AS REQUIRED FOR THE RAMP.13.INTERMEDIATE LANDING AT A CHANGE OF DIRECTION IN EXCESS OF30 DEGREES AND BOTTOM LANDINGS SHALL HAVE A DIMENSION INTHE DIRECTION OF RAMP RUN OF NOT LESS THAN 72" TOACCOMMODATE THE HANDRAIL EXTENSION.14.OTHER INTERMEDIATE LANDINGS SHALL HAVE A DIMENSION IN THEDIRECTION OF RAMP RUN OF NOT LESS THAN 60".15.RAMP LANDINGS ARE NOT CONSIDERED IN DETERMINING THEMAXIMUM HORIZONTAL DISTANCE OF EACH RAMP.16.HANDRAILS ARE REQUIRED ON RAMPS THAT PROVIDE ACCESS IFTHE RAMP SLOPE EXCEEDS 1' RISE IN 20' OF HORIZONTAL RUN,EXCEPT THAT AT EXTERIOR DOOR LANDINGS, HANDRAILS ARE NOTREQUIRED ON RAMPS LESS THAN 6" RISE OR 72" IN LENGTH.17.HANDRAILS SHALL BE PLACED ON EACH SIDE OF EACH RAMP, SHALLBE CONTINUOUS THE FULL LENGTH OF THE RAMP, SHALL BE 34" TO36" ABOVE THE RAMP SURFACE, SHALL EXTEND A MINIMUM OF 1'BEYOND THE TOP AND BOTTOM OF THE RAMP, AND THE ENDS SHALLBE RETURNED.18.THE GRIP PORTION OF HANDRAILS SHALL BE NOT LESS THAN 1-1/4"NOR MORE THAN 1-1/2", OR THE SHAPE SHALL PROVIDE ANEQUIVALENT GRIPPING SURFACE, AND ALL SURFACES SHALL BESMOOTH WITH NO SHARP CORNERS. HANDRAILS SHALL NOT ROTATEWITHIN THEIR FITTINGS.19.HANDRAILS PROJECTING FROM A WALL SHALL HAVE A SPACE OF1-1/2" BETWEEN THE WALL AND THE HANDRAIL.20.HANDRAILS MAY BE LOCATED IN A RECESS IF THE RECESS IS AMAXIMUM OF 3" DEEP AND EXTENDS AT LEAST 18" ABOVE THE TOPOF THE RAIL.21.ANY WALL OR OTHER SURFACE ADJACENT TO HANDRAILS SHALL BEFREE OF SHARP OR ABRASIVE ELEMENTS. EDGES SHALL HAVE AMINIMUM RADIUS OF 1/8".22.WHERE THE RAMP LANDING IS NOT BOUNDED BY A WALL OR FENCE,THERE SHALL BE PROVIDED ON EACH SIDE OF THE RAMP LANDINGWHERE THERE IS A VERTICAL DROP EXCEEDING 4", ONE OF THEFOLLOWING:22.1.A GUIDE CURB, A MINIMUM OF 2" IN HEIGHT; OR22.2.A WHEEL GUIDE RAIL, CENTERED 3" PLUS/MINUS 1" ABOVE THESURFACE OF THE RAMP LANDING23.WHERE THE RAMP SURFACE IS NOT BOUNDED BY A WALL OR FENCEAND THE RAMP EXCEEDS 10' IN LENGTH, THE RAMP SHALL COMPLYWITH ONE OF THE FOLLOWING REQUIREMENTS:23.1. A GUIDE CURB, A MINIMUM OF 2" IN HEIGHT; OR23.2. A WHEEL GUIDE RAIL SHALL BE PROVIDED, CENTERED 3"PLUS/MINUS 1" ABOVE THE SURFACE OF THE RAMP.24.OUTDOOR RAMPS AND THEIR APPROACHES SHALL BE DESIGNEDAND CONSTRUCTED SO THAT WATER WILL NOT ACCUMULATE ONWALKING SURFACES.SPACE ALLOWANCE & REACH RANGES1.THE MINIMUM CLEAR FLOOR OR GROUND SPACE REQUIRED TOACCOMMODATE A SINGLE, STATIONARY WHEELCHAIR ANDOCCUPANT IS 30" BY 48". (THE MINIMUM FLOOR OR GROUND SPACESHALL BE INCREASED TO 42" BY 48" WHEN SUCH SPACE ISPERPENDICULAR TO AN ADJACENT SEATING SPACE). THE MINIMUMCLEAR FLOOR OR GROUND SPACE FOR WHEELCHAIRS MAY BEPOSITIONED FOR FORWARD OR PARALLEL APPROACH TO ANOBJECT. CLEAR FLOOR OR GROUND SPACE FOR WHEELCHAIRS MAYBE PART OF THE KNEE SPACE REQUIRED UNDER SOME OBJECTS.2.ONE FULL UNOBSTRUCTED SIDE OF THE CLEAR FLOOR OR GROUNDSPACE FOR A WHEELCHAIR SHALL ADJOIN OR OVERLAP ANACCESSIBLE ROUTE OR ADJOIN ANOTHER WHEELCHAIR CLEARFLOOR SPACE. IF A CLEAR FLOOR OR GROUND SPACE FOR AWHEELCHAIR IS LOCATED IN AN ALCOVE OR OTHERWISE CONFINEDON ALL OR PART OF THREE SIDES, ADDITIONAL MANEUVERINGCLEARANCES SHALL BE PROVIDED.3.THE SPACE REQUIRED FOR A WHEELCHAIR TO MAKE A 180 DEGREETURN IS A CLEAR SPACE OF 60" DIAMETER OR A T-SHAPED SPACE.4.THE MINIMUM CLEAR WIDTH REQUIRED FOR A WHEELCHAIR TO TURNAROUND AN OBSTRUCTION SHALL BE 36" WHERE THE OBSTRUCTIONIS 48" OR MORE IN LENGTH AND 42" AND 48" WHERE THEOBSTRUCTION IS LESS THAN 48" IN LENGTH.5.THE MINIMUM CLEAR WIDTH FOR SINGLE WHEELCHAIR PASSAGESHALL BE 32" AT A POINT (24" MAXIMUM LENGTH) AND 36"CONTINUOUSLY.6.OPENINGS MORE THAN 24" IN DEPTH SHALL COMPLY WITH CODE.THE MINIMUM WIDTH FOR TWO WHEELCHAIRS TO PASS IS 60".7.IF THE CLEAR FLOOR SPACE ONLY ALLOWS FORWARD APPROACH TOAN OBJECT, THE MAXIMUM HIGH FORWARD REACH ALLOWED SHALLBE 48". THE MINIMUM LOW FORWARD REACH IS 15". IF THE HIGHFORWARD REACH IS OVER AN OBSTRUCTION, REACH ANDCLEARANCES SHALL BE PER BUILDING CODE.8.IF THE CLEAR FLOOR SPACE ALLOWS PARALLEL APPROACH BY APERSON IN A WHEELCHAIR, THE MAXIMUM HIGH SIDE REACHALLOWED SHALL BE 54" AND THE LOW SIDE REACH SHALL BE NOLESS THAN 9" ABOVE THE FLOOR AS SHOWN IN FIGURES 11B-5D(A) &(B). IF THE SIDE REACH IS OVER AND OBSTRUCTION, THE REACH ANDCLEARANCES SHALL BE AS SHOWN IN FIGURE 11B-5D(C).HAZARDS & PROTRUDING OBJECTS1.ABRUPT CHANGES IN LEVEL, EXCEPT BETWEEN A WALK ORSIDEWALK AND AN ADJACENT STREET OR DRIVEWAY, EXCEEDING 4"IN A VERTICAL DIMENSION, SUCH AS AT PLANTERS OR FOUNTAINSLOCATED IN OR ADJACENT TO WALKS, SIDEWALKS, OR OTHERPEDESTRIAN WAYS, SHALL BE IDENTIFIED BY WARNING CURBSPROJECTING AT LEAST 6" IN HEIGHT ABOVE THE WALK OR SIDEWALKSURFACE TO WARN THE BLIND OF A POTENTIAL DROP OFF.2.WHEN A GUARDRAIL OR HANDRAIL IS PROVIDED, NO WARNING CURBIS REQUIRED WHEN A GUIDERAIL IS PROVIDED CENTERED 3" + 1"ABOVE THE SURFACE OF THE WALK OR SIDEWALK, THE WALK IS 5PERCENT OR LESS GRADIENT, OR NO ADJACENT HAZARD EXISTS.3.OBJECTS PROJECTING FROM WALLS WITH THEIR LEADING EDGESBETWEEN 27" AND 80" ABOVE THE FINISHED FLOOR SHALLPROTRUDE NO MORE THAN 4" INTO WALKS, HALLS, CORRIDORS,PASSAGEWAYS, OR AISLES.4.OBJECTS MOUNTED WITH THEIR LEADING EDGES AT OR BELOW 27"ABOVE THE FINISHED FLOOR MAY PROTRUDE ANY AMOUNT INTOWALKS, HALLS, CORRIDORS, PASSAGEWAYS OR AISLES.5.FREE-STANDING OBJECTS MOUNTED ON POSTS OR PYLONS MAYOVERHANG 12" MAXIMUM FROM 27" TO 80" ABOVE THE GROUND ORFINISHED FLOOR.6.PROTRUDING OBJECTS SHALL NOT REDUCE THE CLEAR WIDTH OF ANACCESSIBLE ROUTE OR MANEUVERING SPACE.7.WALKS, HALLS, CORRIDORS, PASSAGEWAYS, AISLES OR OTHERCIRCULATION SPACES SHALL HAVE 80" MINIMUM CLEAR HEAD ROOM.8.ANY OBSTRUCTION THAT OVERHANGS A PEDESTRIAN WAY SHALL BEA MINIMUM OF 80" ABOVE THE WALKING SURFACE AS MEASUREDFROM THE BOTTOM OF THE OBSTRUCTION.9.WHERE A GUY SUPPORT IS USED PARALLEL TO A PATH OF TRAVEL,INCLUDING, BUT NOT LIMITED TO, SIDEWALKS, A GUY BRACE,SIDEWALK GUY OR SIMILAR DEVICE SHALL BE USED TO PREVENT ANOVERHANGING OBSTRUCTION AS DEFINED.10.TRANSIT BOARDING PLATFORMS SHALL HAVE A DETECTABLEWARNING TEXTURE EXTENDING THE FULL LENGTH OF THE LOADINGAREA. THIS DETECTABLE WARNING TEXTURE SHALL HAVE THEFOLLOWING FEATURES:10.1.WIDTH 24" TO 36", PLACED AT THE EDGE OF THE DROP-OFF ORSAFE AREA.10.2.DURABLE, SLIP-RESISTANT MATERIAL HAVING A SURFACE TEXTURECOMPOSED OF RAISED, TRUNCATED DOMES IN A STAGGEREDPATTERN WITH A DIAMETER OF NOMINAL 0.9" AT THE BASETAPERING TO 0.45" AT THE TOP, A HEIGHT OF NOMINAL 0.2", AND ACENTER-TO-CENTER SPACING OF NOMINAL 2.35" . THE DETECTABLEWARNING SHALL CONTRAST VISUALLY WITH ADJOINING SURFACES,EITHER LIGHT ON DARK OR DARK ON LIGHT. THE MATERIAL USEDTO PROVIDE CONTRAST SHALL BE AN INTEGRAL PART OF THEWALKING SURFACE. WARNING SURFACES SHALL DIFFER FROMADJOINING WALKING SURFACES IN RESILIENCY OR SOUND ONCANE CONTACT. THIS SURFACE SHALL BE RESERVED FORWARNING.10.3. COLOR YELLOW CONFORMING TO FEDERAL COLOR NO.33538, ASSHOWN IN TABLE IV OF STANDARD NO. 595B. WHERE THE COLORVALUE CONTRAST BETWEEN THE YELLOW WARNING AND THE MAINWALKING SURFACE IS LESS THAN 70 %, A 1" WIDE BLACK STRIPSHALL SEPARATE THE YELLOW WARNING FROM THE MAIN WALKINGSURFACE.11.AT TRANSIT BOARDING PLATFORMS, THE PEDESTRIAN ACCESSSHALL BE IDENTIFIED WITH A DETECTABLE DIRECTIONAL TEXTURE.THIS DETECTABLE DIRECTIONAL SHALL BE 0.1" IN HEIGHT THATTAPERS OFF TO 0.04", WITH BARS RAISED 0.2" FROM THE SURFACE.THE RAISED BARS SHALL BE 1.3" WIDE AND 3.0" FROMCENTER-TO-CENTER OF EACH BAR. THIS SURFACE SHALL DIFFERFROM ADJOINING WALKING SURFACES IN RESILIENCY OR SOUND ONCANE CONTACT. THE COLOR OF THE DIRECTIONAL TEXTURE SHALLCOMPLY WITH BUILDING CODE. THIS SURFACE WILL BE PLACEDDIRECTLY BEHIND THE YELLOW DETECTABLE WARNING TEXTURE,ALIGNING WITH ALL DOORS OF THE TRANSIT VEHICLES, WHEREPASSENGERS WILL EMBARK. THE WIDTH OF THE DIRECTIONALTEXTURE SHALL BE EQUAL TO THE WIDTH OF THE TRANSITVEHICLE'S DOOR OPENING. THE DEPTH OF THE TEXTURE SHALL NOTBE LESS THAN 36".12.IF A WALK CROSSES OR ADJOINS A VEHICULAR WAY, AND THEWALKING SURFACES ARE NOT SEPARATED BY CURBS, RAILINGS, OROTHER ELEMENTS BETWEEN THE PEDESTRIAN AREAS ANDVEHICULAR AREAS, THE BOUNDARY BETWEEN THE AREAS SHALL BEDEFINED BY A CONTINUOUS DETECTABLE WARNING WHICH IS 36"WIDE.EMPLOYEE WORK AREAS & WORK STATIONSNOTE 1: GENERAL EMPLOYEE AREAS ARE "THOSE AREAS COMMONLY USEDBY MULTIPLE EMPLOYEES, SUCH AS RESTROOMS, BREAK ROOMS,CONFERENCE AND MEETING SPACE, ETC.". EVEN WHEN THESE AREAS ARERESTRICTED FOR EMPLOYEE USE ONLY, THEY MUST COMPLY WITH ADAACCESSIBILITY REQUIREMENTS.NOTE 2: SPECIFIC WORK STATIONS IS INTENDED TO MEAN "PLACES WHEREINDIVIDUALS DO THEIR WORK, SUCH AS A CHEF'S CHOPPING BLOCK IN ACOMMERCIAL RESTAURANT OR A COMPUTER TERMINAL IN AN OFFICE".THESE WORK STATIONS ARE NOT REQUIRED TO BE ACCESSIBLETHEMSELVES, EXCEPT THAT AISLE AND FLOOR AND LEVEL REQUIREMENTSMUST BE MET AND ENTRYWAYS MUST BE AT LEAST 32" IN CLEAR WIDTH.1.SPECIFIC WORK STATIONS, WITH THE EXCEPTION OF WORKSTATIONS IN SALES FACILITIES, CHECKSTANDS, TICKET BOOTHS,AND OTHER WORK STATIONS WITH SPECIFIC REQUIREMENTSCONTAINED IN OTHER PORTIONS OF THE REGULATIONS, NEED ONLYCOMPLY WITH AISLE WIDTH AND FLOORS AND LEVELS, ANDENTRY-WAYS SHALL BE 32 " IN CLEAR WIDTH.2.EMPLOYEE WORK AREAS SHALL BE ACCESSIBLE BY MEANS OF A 36"MINIMUM AISLE AND A 32" MINIMUM CLEAR OPENING DOOR WIDTH.3.CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITHONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, ORTWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATECONTROLS SHALL BE NO GREATER THAN 5 POUNDS OF FORCE.4.NON-COMMERCIAL KITCHEN AND COUNTER BAR SINKS LOCATED INCOMMON USE AREAS SHALL HAVE FAUCET CONTROLS ANDOPERATING MECHANISMS OPERABLE WITH ONE HAND INACCORDANCE WITH SECTION 1118B AND SHALL NOT REQUIREGRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCEREQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5PLF. LEVER-OPERATED, PUSH-TYPE, AND ELECTRONICALLYCONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLEDESIGNS. SELF-CLOSING VALVES ARE ALLOWED IF THE FAUCETREMAINS OPEN FOR AT LEAST 10 SECONDS.5.VENDING MACHINES SHALL BE INSTALLED IN COMPLIANCE WITHBUILDING CODE.STORAGE FACILITIES & AREAS1.IF FIXED STORAGE FACILITIES SUCH AS CABINETS, SHELVES,CLOSETS, OR DRAWERS ARE PROVIDED WHERE ACCESS ISREQUIRED, AT LEAST ONE OF EACH TYPE SHALL BE ACCESSIBLE INTERMS OF CLEAR SPACE, REACH RANGES, AND HARDWARE.ADDITIONAL STORAGE MAY BE PROVIDED OUTSIDE OF REQUIREDREACH RANGES.2.A CLEAR FLOOR SPACE AT LEAST 30" BY 48" THAT ALLOWS EITHER AFORWARD OR PARALLEL APPROACH BY A PERSON USING AWHEELCHAIR SHALL BE PROVIDED AT ACCESSIBLE STORAGEFACILITIES.3.ACCESSIBLE STORAGE SPACES SHALL BE WITHIN AT LEAST ONE OFTHE HEIGHT RANGES SPECIFIED IN BUILDING CODE.4.HARDWARE FOR ACCESSIBLE STORAGE FACILITIES SHALL BE WITHINAT LEAST ONE OF THE HEIGHT RANGES SPECIFIED IN BUILDING CODEAND SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRETIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THEFORCE REQUIRED TO ACTIVATE THE HARDWARE SHALL BE NOGREATER THAN 5 POUNDS. TOUCH LATCHES AND U-SHAPED PULLSARE ACCEPTABLE.5.CLOTHES RODS SHALL BE A MAXIMUM OF 54" FROM THE FLOOR FORA SIDE APPROACH. WHERE THE DISTANCE FROM THE WHEELCHAIRTO THE CLOTHES ROD OR SHELF EXCEEDS 10", AS IN CLOSETSWITHOUT ACCESSIBLE DOORS, THE HEIGHT AND DEPTH TO THE RODOR SHELF SHALL COMPLY WITH BUILDING CODE.6.THE DOORWAY PROVIDING ACCESS TO STORAGE AREAS SHALL BENOT LESS THAN 32" IN CLEAR WIDTH. STORAGE AREAS SHALL BEMADE ACCESSIBLE AS REQUIRED.SIGNS & IDENTIFICATIONNOTE: THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE THESTANDARD USED TO IDENTIFY FACILITIES THAT ARE ACCESSIBLE TO ANDUSABLE BY PHYSICALLY DISABLED PERSONS AS SET FORTH IN ADA AND ASSPECIFICALLY REQUIRED BELOW.1.THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL CONSIST OFA WHITE FIGURE ON A BLUE BACKGROUND. THE BLUE SHALL BEEQUAL TO COLOR NO. 15090 IN FEDERAL STANDARD 599B.2.LETTERS AND NUMBERS ON SIGNS SHALL HAVE A WIDTH-TO-HEIGHTRATIO OF BETWEEN 3:5 AND 1:1 AND A STROKE WIDTH-TO-HEIGHTRATIO BETWEEN 1:5 AND 1:10.3.CHARACTERS AND NUMBERS ON SIGNS SHALL BE SIZED ACCORDINGTO THE VIEWING DISTANCE FROM WHICH THEY ARE TO BE READ. THEMINIMUM HEIGHT IS MEASURED USING AN UPPER CASE X. LOWERCASE CHARACTERS ARE PERMITTED. FOR SIGNS SUSPENDED ORPROJECTED ABOVE THE FINISH FLOOR IN COMPLIANCE, THEMINIMUM CHARACTER HEIGHT SHALL BE 3".4.CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIRBACKGROUND, EITHER LIGHT CHARACTERS ON A DARKBACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND.5.WHEN RAISED CHARACTERS OR SYMBOLS ARE USED, THEY SHALLCONFORM TO THE BUILDING CODE.5.1.LETTERS AND NUMBERS ON SIGNS SHALL BE RAISED 1/32" MINIMUMAND SHALL BE SANS-SERIF UPPERCASE CHARACTERSACCOMPANIED BY GRADE 2 BRAILLE.5.2.RAISED CHARACTERS OR SYMBOLS SHALL BE A MINIMUM OF 5/8"HIGH.5.3.PICTORIAL SYMBOL SIGNS (PICTOGRAMS) SHALL BE ACCOMPANIEDBY THE EQUIVALENT VERBAL DESCRIPTION PLACED DIRECTLYBELOW THE PICTOGRAM. THE BORDER DIMENSION OF THEPICTOGRAM SHALL BE A MINIMUM OF 6" IN HEIGHT.6.CONTRACTED GRADE 2 BRAILLE SHALL BE USED WHEREVER BRAILLESYMBOLS ARE SPECIFICALLY REQUIRED IN OTHER PORTIONS OFTHESE REGULATIONS. DOTS SHALL BE 1/10" ON CENTERS IN EACHCELL WITH 2/10" SPACE BETWEEN CELLS. DOTS SHALL BE RAISED AMINIMUM OF 1/40" ABOVE THE BACKGROUND.7.ALL BUILDING ENTRANCES THAT ARE ACCESSIBLE TO AND USABLEBY PERSONS WITH DISABILITIES AND AT EVERY MAJOR JUNCTIONALONG OR LEADING TO AN ACCESSIBLE ROUTE OF TRAVEL SHALL BEIDENTIFIED WITH A SIGN DISPLAYING THE INTERNATIONAL SYMBOLOF ACCESSIBILITY AND WITH ADDITIONAL DIRECTIONAL SIGNS, ASREQUIRED, TO BE VISIBLE TO PERSONS ALONG APPROACHINGPEDESTRIAN WAYS.8.WHEN PERMANENT IDENTIFICATION IS PROVIDED FOR ROOMS ANDSPACES, RAISED LETTERS SHALL BE PROVIDED AND SHALL BEACCOMPANIED BY BRAILLE IN CONFORMANCE WITH CODE. SIGNSSHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDEOF THE DOOR. WHERE THERE IS NO WALL SPACE ON THE LATCHSIDE, INCLUDING AT DOUBLE LEAF DOORS, SIGNS SHALL BE PLACEDON THE NEAREST ADJACENT WALL, PREFERABLY ON THE RIGHT.MOUNTING HEIGHT SHALL BE 60" ABOVE THE FINISHED FLOOR TOTHE CENTERLINE OF THE SIGN. MOUNTING SIGNAGE WITHOUTENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THESWING OF A DOOR.9.POLE SUPPORTED PEDESTRIAN TRAFFIC CONTROL BUTTONS SHALLBE IDENTIFIED WITH COLOR CODING CONSISTING OF A TEXTUREDHORIZONTAL YELLOW BAND 2" IN WIDTH ENCIRCLING THE POLE, ANDA 1" WIDE DARK BORDER BAND ABOVE AND BELOW THIS YELLOWBAND. COLOR CODING SHOULD BE PLACED IMMEDIATELY ABOVETHE CONTROL BUTTON. CONTROL BUTTONS SHALL BE LOCATED NOHIGHER THAN 48" ABOVE THE SURFACE ADJACENT TO THE POLE.GENERAL ASSOCIATED NOTESFOLLOW ALL LOCAL JURISDICTION CODESA1.1ACCESSIBILITY NOTES
<br />3883 Ruffin Road Suite B
<br />San Diego, CA 92123
<br />p: 714/560/8200
<br />f: 714/560/8211
<br />www.tait.com
<br />Since 1964 Los Angeles
<br />Anaheim
<br />Ontario
<br />Sacramento
<br />San Diego
<br />Boise
<br />Dallas
<br />Denver
<br />Seattle
<br />©"TAIT & ASSOCIATES" 2020 ALL RIGHTS RESERVED
<br />Job#:
<br />Scale:
<br />Date:
<br />Drawn By:
<br />Checked By:
<br />Rev. #Date DescriptionSHEET:7-ELEVEN, INC.
<br />3200 HACKBERRY, IRVING, TEXAS 75063
<br />SE1237
<br />7-ELEVEN 1046249
<br />1110 N. MAIN ST
<br />MANTECA, CA 95336
<br />TICOFALCC 1 9 0 9 1L
<br />11 / 21EXPIRESETSTAFOIA
<br />NR SNI
<br />C
<br />E
<br />EDCHRAIETA
<br />EN
<br />FR
<br />JR.EK
<br />ALLPNSI
|