COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
26 (STATE ROUTE 26)
>
16401
>
2800 - Aboveground Petroleum Storage Program
>
PR0528828
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 8:48:38 AM
Creation date
11/16/2022 4:39:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0528828
PE
2832
FACILITY_ID
FA0009357
FACILITY_NAME
MID VALLEY AG SERVICES INC
STREET_NUMBER
16401
Direction
E
STREET_NAME
STATE ROUTE 26
City
LINDEN
Zip
95236
CURRENT_STATUS
01
SITE_LOCATION
16401 E HWY 26
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S A N J 0 A Q I I I Irl Environmental Health Department <br /> CCUN r <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> MID VALLEY AG SERVICES INC 1 16401 E HWY 26 , LINDEN November 14, 2022 <br /> SPCC Plan Requirements for Onshore Facilities(excluding production facilities) <br /> 719 CFR 112.8(c)(11) Failed to locate properly or provide sufficient secondary containment for mobile/portable containers ❑V ❑R ❑COS <br /> 720 CFR 112.8(d)(1) Failed to take corrective action on buried piping when exposed for any reason ❑V ❑R ❑COS <br /> 721 CFR 112.8(d)(1) Failed to provide corrosion protection for buried piping ❑V ❑R ❑COS <br /> 722 CFR 112.8(d)(2) Failed to cap/blank-flange connection at transfer point and mark its origin if not in service ❑V ❑R ❑COS <br /> 723 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion/corrosion and to allow for expansion/contraction ❑V ❑R ❑COS <br /> 724 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves,piping,and appurtenances ❑V ❑R ❑COS <br /> 725 CFR 112.8(d)(4) Failed to conduct integrity and leak testing on buried piping any time it is worked on ❑V ❑R ❑COS <br /> 726 CFR 112.8(d)(5) Failed to adequately warn vehicles entering facility to protect piping and other transfer operations ❑V ❑R ❑COS <br /> 727 CFR 112.7(a)(1), Plan failed to adequately describe overfill prevention methods for each container ❑V ❑R ❑COS <br /> 112.8(c)(8) <br /> Other Violations <br /> 4010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 4020 See below Unlisted Training violation u V o R ❑COS <br /> 4030 See below Unlisted Operations/Maintenance violation n V ❑R ❑COS <br /> 4040 See below Unlisted Release/Leaks/Spills violation ❑V ❑R ❑COS <br /> 4050 See below Unlisted Abandonment/Illegal Disposal/Unauthorized Treatment violation u V u R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 112 CFR 112.20(e) Failure to complete and maintain a Substantial Harm Criteria certification. <br /> OBSERVATION: The facility failed to complete and maintain (at the facility)the Substantial Harm Criteria <br /> certification form, and Compliance Officer Sam Robinson, determined that the facility could not be reasonably <br /> expected to cause substantial harm to the environment.The Substantial Harm Criteria certification form was not <br /> signed. <br /> REGULATION GUIDANCE: (e) If the owner or operator of a facility determines pursuant to paragraph (a)(2)of this <br /> section that the facility could not, because of its location, reasonably be expected to cause substantial harm to the <br /> environment by discharging oil into or on the navigable waters or adjoining shorelines,the owner or operator shall <br /> complete and maintain at the facility the certification form contained in appendix C to this part and, in the event an <br /> alternative formula that is comparable to one contained in appendix C to this part is used to evaluate the criterion in <br /> paragraph (f)(1)(ii)(B)or(f)(1)(ii)(C)of this section,the owner or operator shall attach documentation to the <br /> certification form that demonstrates the reliability and analytical soundness of the comparable formula and shall <br /> notify the Regional Administrator in writing that an alternative formula was used. <br /> CORRECTIVE ACTION: The Substantial Harm Criteria certification form was corrected during the inspection. <br /> This is a Class II violation. <br /> FA0009357 PR0528828 SCO01 11/14/2022 <br /> EHD 28-01 Rev.12/06/2021 Page 4 of 10 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.