TAG PART # CFM GPM
<br />ZON
<br />E COVEREDBY SP WEIGHT VELOCITY QTY DESCRIPTION
<br />P1 DW1407LT 1800 -0.003 3.63 1683.79 1
<br />SINGLE WALL DUCT 14" DIAMETER, 7" LONG, FLANGE AT BOTH ENDS. STAINLESS STEEL.
<br />P2 DW1490ASY 1800 -0.1418 10.62 1683.79 1
<br />SINGLE WALL DUCT 90 DEGREE ELBOW, 14" DUCT, ASSEMBLY.
<br />P3 DW1404C1D 1800 -0.002 2.45 1683.79 1 SINGLE WALL DUCT OFF SET COLLAR - 14" DIAMETER DUCT - 1/4" PITCH.
<br />P4 DW1447LT 1800 -0.02 21.79 1683.79 1
<br />SINGLE WALL DUCT 14" DIAMETER, 47" LONG, FLANGE AT BOTH ENDS. STAINLESS STEEL.
<br />P5 DW1447LT 1800 -0.02 21.79 1683.79 1
<br />SINGLE WALL DUCT 14" DIAMETER, 47" LONG, FLANGE AT BOTH ENDS. STAINLESS STEEL.
<br />P6 DW14SUBRASY 2.96 1 DUCT SUPPORT BRACKET KIT, 14" DUCT, USED FOR HANGING DUCT. 12 GA STEEL, CLEAR ZINC COATING. - 2
<br />RINGS, 4 BRACKETS, & HARDWARE BAG 2.
<br />P7
<br />ASSEMBLED W/P20 DW14TEASY 1800 1 -0.011 15.95 1683.79 1
<br />SINGLE WALL DUCT TEE, 14" DUCT, ASSEMBLY.
<br />P8 DW1447LT 1800 -0.02 21.79 1683.79 1 SINGLE WALL DUCT 14" DIAMETER, 47" LONG, FLANGE AT BOTH ENDS. STAINLESS STEEL.
<br />P9 DW14SUBRASY 2.96 1 DUCT SUPPORT BRACKET KIT, 14" DUCT, USED FOR HANGING DUCT. 12 GA STEEL, CLEAR ZINC COATING. - 2
<br />RINGS, 4 BRACKETS, & HARDWARE BAG 2.
<br />P10 DW1447LT 1800 -0.02 21.79 1683.79 1 SINGLE WALL DUCT 14" DIAMETER, 47" LONG, FLANGE AT BOTH ENDS. STAINLESS STEEL.
<br />P11 DW1447LT 1800 -0.02 21.79 1683.79 1 SINGLE WALL DUCT 14" DIAMETER, 47" LONG, FLANGE AT BOTH ENDS. STAINLESS STEEL.
<br />P12 DW1404C1D 1800 -0.002 2.45 1683.79 1 SINGLE WALL DUCT OFF SET COLLAR - 14" DIAMETER DUCT - 1/4" PITCH.
<br />P13
<br />ASSEMBLED W/P14 DW14TEASY 1800 1 -0.081 15.95 1683.79 1 SINGLE WALL DUCT TEE, 14" DUCT, ASSEMBLY.
<br />P14
<br />ASSEMBLED W/P13 O=S DW1415ADKIT 3.72 1 DUCT ACCESS DOOR WITH HANDLE & GREASE DAM, FOR 14" DUCT USE 15" DOOR. STAINLESS STEEL.
<br />P15 DW1417LT 1800 -0.0072 8.22 1683.79 1
<br />SINGLE WALL DUCT 14" DIAMETER, 17" LONG, FLANGE AT BOTH ENDS. STAINLESS STEEL.
<br />P16 DW1418AJDKIT 1800 -0.0048 11.56 1683.79 1
<br />SINGLE WALL DUCT ADJUSTABLE, 14" DIAMETER, 17.5" LONG, FLANGE AT ONE END WITH A 14" ADJUSTABLE
<br />COLLAR - STAINLESS STEEL.
<br />P17
<br />ASSEMBLED W/P18 DW1435LT 1800 -0.015 16.34 1683.79 1
<br />SINGLE WALL DUCT 14" DIAMETER, 35" LONG, FLANGE AT BOTH ENDS. STAINLESS STEEL.
<br />P18
<br />ASSEMBLED W/P17 DW1914TPDBEX 1800 7.50 1683.79 1
<br />DUCT TO CURB TRANSITION 3/4" DOWN TURN, 19-1/2" CURB TO 14" DUCT, 16 GA ALUMINIZED. FOR USE WITH
<br />EXHAUST FANS.
<br />SYSTEM AT P18 -1.0653 0.00
<br />P19 DW14SUBRASY 2.96 1 DUCT SUPPORT BRACKET KIT, 14" DUCT, USED FOR HANGING DUCT. 12 GA STEEL, CLEAR ZINC COATING. - 2
<br />RINGS, 4 BRACKETS, & HARDWARE BAG 2.
<br />P20
<br />ASSEMBLED W/P7 O=T DW1415ADKIT 3.72 1 DUCT ACCESS DOOR WITH HANDLE & GREASE DAM, FOR 14" DUCT USE 15" DOOR. STAINLESS STEEL.
<br />3M-2000PLUS 0.80 4 DUCT - 3M FIRE BARRIER 2000 PLUS SILICONE - USED AS SEALANT TO SEAL DUCT JOINTS.
<br />DW14CLASY 1.06 16 DUCT "V" CLAMP WITH NEW DESIGN 14 GA BRACKETS, 14" DUCT, ASSEMBLY.
<br />TOTAL WEIGHT 240.10
<br />SINGLE WALL FACTORY BUILT DUCTWORK
<br />- FOR A COMPLETE LIST OF APPROVED SUPPORT METHODS, SEE THE INSTALLATION AND OPERATION MANUAL.
<br />- ALL DUCTWORK IS REQUIRED TO BE INSTALLED WITH THE MAXIMUM SUPPORT SPACING LISTED BELOW.
<br />DUCT DIAMETER
<br />8"
<br />10'10'24'
<br />10"
<br />10'10'24'
<br />12"
<br />10'10'24'
<br />14"
<br />10'10'24'
<br />16"
<br />10'10'24'
<br />18"
<br />10'10'24'
<br />20"
<br />10'10'24'
<br />22"
<br />10'10'24'
<br />24"
<br />10'10'24'
<br />HORIZONTAL
<br />SUPPORT (FT)
<br />VERTICAL
<br />WALL SUPPORT (FT)
<br />VERTICAL
<br />CURB SUPPORT (FT)
<br />10'10'24'
<br />10'10'24'
<br />10'10'24'
<br />5"
<br />6"
<br />7"
<br />26"
<br />28"
<br />30"
<br />32"
<br />10'10'24'
<br />34"
<br />10'10'24'
<br />36"
<br />10'10'24'
<br />10'10'24'
<br />10'10'24'
<br />10'10'24'
<br />- DUCTWORK SHALL SLOPE NOT LESS THAN 1/16" PER LINEAR FOOT TOWARDS THE HOOD OR AN APPROVED GREASE COLLECTION RESERVOIR.
<br />- WHERE HORIZONTAL DUCTS EXCEED 75 FEET IN LENGTH, THE SLOPE SHALL NOT BE LESS THAN 3/16" PER LINEAR FOOT.
<br />DO NOT LEAK TEST USING SMOKE BOMBS CONTAINING
<br />CHLORINES/CHLORIDES. CONSULT WITH CAPTIVEAIRE
<br />FOR PROPER LEAK TESTING METHODS.
<br />SHEET NO.
<br />SCALE:
<br />DWG.#:
<br />DRAWN
<br />DATE:
<br /> BY:
<br />REVISIONS
<br />www.captiveaire.com ACCORDANCENo. 96BUILTNFPAWITHINSLIDTER4996088
<br />MASTER DRAWING
<br />AH-86Mountain Mike's Pizza - Mountain House CAMountain House, CA, 95391Southern California Office3002 Dow Ave., Suite 410, Tustin, CA, 92780 PHONE: (714) 957-1500 FAX: (919) 227-5975 EMAIL: reg86@captiveaire.comCAPTIVEAIRE DRAWINGS
<br />M-4.6
<br />PRINTED DATE: 07-21-2021PROJECT NAME/ADDRESS:
<br />STAMP
<br />@Mountain House
<br />ARCHITECT
<br />ARCH PROJECT #:
<br />JOB NUMBER
<br />DRAWN BY
<br />SHEET CONTENT
<br />SHEET NO
<br />ISSUE DATE:
<br />REVISIONS:
<br />EM
<br />21-___
<br />CHECK BY
<br />ADR
<br />ARCHITECTURE
<br />GWA
<br />1000 Corporate Center Drive
<br />Suite 550
<br />Monterey Park, CA 91754
<br />tel: (626) 288-6898
<br />Member of The American Institute of Architects
<br />REN. 04-30-2023
|