WH <br />BK <br />A B C D E F G H I <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />FACTORY WIRING <br />SCHEMATIC <br />CIRCUIT BOARDS <br />DCV Rev. 2.12.00 <br />HMI Rev. 2.12.00 <br />MOTOR POWER CIRCUIT <br />PANEL LID <br />COMPONENT LIST <br />LABEL DESCRIPTION <br />ST-X <br />varies <br />Starter <br />OL-X <br />varies <br />Overload <br />C-X <br />varies <br />Contactor <br />TS-x <br />A/CP-PO-T4"-EXPL <br />Duct Thermostat <br />120 VAC <br />RELAY <br />RA-x <br />24 VDC <br />RELAY <br />RD-x <br />PS-1 MDP18-24A-1C <br />Power Sup. 24VDC <br />BK <br />RA-x 34.110.0184.0 <br />120V Relay DPDT <br />WH <br />RA-x 34.110.0184.0 <br />120V Relay DPDT <br />GR <br />UNLESS SPECIFIED OTHERWISE, ALL FACTORY AC WIRING 16 AWG. ALL FACTORY DC WIRING 18 AWG. <br />N1 <br />H1 DC-GND8H1 <br />7PCU <br />6ST <br />5KS <br />4KTS <br />3GAS <br />2AR1 <br />1N1 <br />120VJ9 <br />5OV1 <br />4SF1 <br />3EF1 <br />2B1 <br />1IO1 <br />120VJ7 <br />AR1 <br />H12x <br />N12x <br />B1 <br />EF1 <br />SF1 <br />BK IO1 <br />BK <br />BK <br />BK <br />JUMPERW1 <br />BK 14AWG BK <br />64 <br />RD-1 <br />BL PR <br />RD-x <br />34.110.0188.0 <br />24VDC Light Relay <br />BK WHSF1RA-2 <br />RD-1 <br />N1N1 <br />24V <br />1234567 <br />8 9 1011121314 <br />J6 <br />FAN <br />PANEL COOLING <br />DRY CONTACTS (SHOWN DE-ENERGIZED) <br />HOOD LIGHTS <br />AR1 H1JUMPER FIRE SYSTEM <br />BK <br />BK <br />BK <br />GAS <br />KS <br />ST <br />NOTE: Configure ECPM03 for CORE <br />ECPM03 <br />J10 IL1AIL1BJUMPER <br />MAKE UP AIR INTERLOCK. <br />J3 <br />ECPM03 or Previous EOL <br />J5 <br />MASTER CORE <br />RA-2-1 <br />SFC1SFO1 <br />14 AWG <br />YW <br />RA-2-2 <br />SFC2SFO2 <br />14 AWG <br />YW <br />SC-20 x 18 x 8.62 BOX <br />CONTROL INPUT 120V <br />H1=LINE, N1=NEUTRAL, 15A <br />BREAKER. DO NOT CONNECT <br />TO SHUNT TRIP BREAKER. <br />SEE INSTALLATION <br />SCHEMATIC FOR ADDITIONAL <br />REQ. <br />LEGENDWH/BLBLH1N1DC-DC+LN <br />-+ <br />PS-01 <br />AC <br />24VDCKSKSBKKS <br />BK <br />BK <br />GAS <br />ST <br />BKEF1 <br />WH GR/YWWH/BLBLPRDC+GNDRO1RO1DC+ <br />FAN <br />SECONDARY PANEL COOLING IF NECESSARY <br />EF1 WHBK <br />MSC-01 <br />J7 <br />J8 <br />J7 <br />J8 <br />MSC-02 <br />J3 <br />ECPM03/DAISY CHAIN <br />NOTE: All items on ECPM03 J3 line to be daisy chained <br />from one component to the next, with EOL120A at end <br />of line. Place PN: EOL120A in empty RJ45 port. <br />J4 J5 <br />10OUT <br />10IN JUMPER <br />10OUT <br />10IN JUMPER <br />JUMPER <br />ECPM03J10 IL2AIL2BTERMINAL GAS USED FOR <br />120V POWERED GAS VALVES <br />ONLY <br />4996088 <br />Mountain Mike's ... <br />FACTORY <br />SC-111110FP <br />7/20/2021 <br />ECP #1-5 <br />120V 1 Phase w/ control for 1 <br />Exhaust Fan, 1 Supply Fan, <br />Exhaust on in Fire, Lights out in <br />Fire, Fan(s) On/Off Thermostatically <br />Controlled. Room temperature <br />sensor shipped loose for field <br />installation. <br />A B C D E F G H I <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />FACTORY WIRING <br />SCHEMATIC <br />CORE FIRE <br />PROTECTION <br />COMPONENT LIST <br />LABEL DESCRIPTION <br />120 VAC <br />RELAY <br />RA-x <br />24 VDC <br />RELAY <br />RD-x <br />24 VOLT BATTERY PACK5 AMP FUSE <br />RD <br />SHIELDED TWISTED PAIR <br />PCB-2 <br />J3-2 <br />J4-1 <br />J3-11 <br />J4-3 <br />J4-2 <br />J4-8 <br />J4-9 <br />J4-12 <br />J3-14 <br />J4-5 <br />J3-13 <br />J3-4 <br />J4-6 <br />J3-10 <br />J2-1 <br />J2-2 <br />J2-3 <br />J2-4 <br />J7-2 <br />J7-3 <br />J7-1 <br />J3-1 J3-3 <br />RD <br />RD BR <br />RD <br />ALL 18AWG <br />RD BK <br />ORRD <br />PKRD <br />BRRD <br />RD OR/BL <br />BK 18AWG <br />BK <br />BK <br />J3-5 <br />J1-1 <br />J1-2 <br />PK <br />RD <br />BK <br />BK <br />RD <br />FIRE STAT SUPERVISED LOOP <br />May be mixed factory and field wiring. See <br />Installation Schematic. Multiple fire sensors <br />possible. <br />+ <br />+ <br />RD <br />BK <br />BK <br />RD <br />Shield <br />BK <br />RD <br />RS-485 CORE INTERLOCK <br />NETWORK. Connection to other <br />CORE Panels or Communication <br />Module. See Installation Schematic <br />for Connection. <br />N1D 3xH1D3x <br />DISCONNECT J1 <br />21 <br />22 <br />23 <br />24 <br />16AWG <br />WHN1 <br />H1 <br />PN: 1606-XLP-60EQ <br />Adjust power supply to 27.5 Volts with an <br />accurate Digital Volt Meter or with an HMI <br />plugged into the CORE board. <br />NL <br />+-PSM-2 60W <br />GR <br />BK <br />GND <br />PCB-2 PCBCORE-APP <br />CORE PCB <br />PSM-2 <br />1606-XLP-50E <br />CORE POWER SUPPLY <br />WS-x <br />varies <br />Water Solenoid <br />LT-06 PNL-1163-0UR <br />24V Red Ind. Light <br />LL-01 AQ5510 <br />Surf. Level Sensor <br />AA-01 SCE120LA3FP1B <br />Audible Alarm <br />PB-01 D7-F2X11 <br />Prime/Reset Switch <br />SW-04 <br />BZ-2RQ1-A2 <br />Tamper Switch <br />SP-1 <br />50000-805 <br />Surfactant Pump <br />35 <br />PB-01 <br />Prime / Reset <br />RD-20 <br />Trouble Relay <br />RD-17 <br />Fire Relay <br />DRY CONTACTS (SHOWN DE-ENGERGIZED) <br />AA-01 <br />Audible Alarm <br />SW-04 <br />Door Tamper Switch <br />CNO <br />FS-01 <br />BK WH <br />Fire Stat <br />FS-02 <br />BK WH <br />Fire Stat <br />HIGH TEMP WIRE (842 F), PN: <br />SLPCON-xFT required for all <br />Supervised Loop wiring in contact with <br />a hood. All other wiring shall be PN: <br />6320UL, Belden or similar. Factory <br />mounted hood sensors will be <br />terminated at junction box on top of <br />hood. <br />GV-1 <br />24V DC Gas Valve <br />GV-1 varies <br />24v DC Gas Valve <br />RD RD <br />INTERLOCK FOR AUTOMAN ACTIVATION. Used <br />for activating 120V automan or adjacent Master <br />CORE panels during active Fire Condition. <br />RD-18-1 <br />YW <br />J3-16 <br />J3-8 BR 38 <br />LT-6 <br />R <br />FIRE INDICATOR <br />DIP Switch <br />ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD <br />BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES. <br />RD/GNRDRD-19 <br />Equipment Relay COOKING EQUIPMENT DISABLE RELAY. For UDS <br />Kill Switch, wire EKC and EKS terminals to like <br />terminals in UDS panel. <br />RD-19-1 <br />EKC <br />ESTEKS <br />YW <br />INTERLOCK FOR AUTOMAN ACTIVATION. Used <br />for activating 120V automan or adjacent Master <br />CORE panels during active Fire Condition. <br />RD-18-1 <br />YW <br />RD OR/BLRD-18 <br />Auxiliary Interlock Relay <br />FS-XX 12-F28021-000360 <br />Duct Fire Sensor <br />LT-05 PNL-1163-0UY <br />24V YLW Ind. Light <br />PS-01 <br />STI-SS2431 <br />Remote Pull Station <br />FOR SHIPMENT <br />J10-1 <br />J10-2 <br />J10-3 <br />J10-4 <br />RD <br />BK <br />BK <br />RD <br />101 <br />102 <br />103 <br />104 <br />MANUAL ACTUATION LOOP / REMOTE FIRE SYSTEM <br />LOOP. <br />Multiple manual actuation possible. <br />A Plug jumper with wires from pin1 to pin4 and from pin2 to <br />pin3 should be mounted on J10 if there is no manual <br />actuation device and no microswitch. <br />Jumper if water valve <br />supervision switch is used <br />MAD-01CNO <br />ManualActuation <br />Device <br />MS-01 <br />CNO <br />Micro SW <br />12345678 <br />SW1OPEN <br />PUT END OF LINE PLUG IN EMPTY RJ45 <br />J3 ECPM03 <br />UNLESS PCU AFM OR OTHER COMPONENT IN SERIES. <br />CAT-5 WIRING (MASTER ONLY) <br />FIELD WIRED IF REMOTE PREWIRE <br />RD-XX <br />PLC-RPT-24DC/21 <br />24VDC Phoenix Relay <br />AUX-01 <br />AU1 AU2 <br />Auxiliary Interlock (AUX-01): <br />Wire AU1 / AU2 of adjacent Master CORE panel(s) in each <br />manual activation loop for simultaneous activation. <br />AU1/AU2 will have continuity for 10 seconds if adjacent panel <br />goes into fire condition, activating this CORE Panel but <br />allowing for a reset after 10 seconds. <br />NOTE: AU1/AU2 terminals of CORE Panel should not be <br />wired into its own manual activation loop.Adjacent <br />CORE Panel <br />Master CORE set DIP <br />SW 8 to CLOSED <br />position. Slave CORE <br />with address 1 set <br />DIP SW 8 to <br />CLOSED position. All <br />other CORES set DIP <br />SW 8 OPEN. <br />18AWG <br />LEGEND <br />FIRE INDICATOR FAULT CONDITION FLASH CODES <br />2 Release Solenoid <br />3 Pressure Switch <br />4 Auxiliary Fault <br />5 Microcontroller Fault <br />6 N/A <br />7 Supervised Loop <br />8 Ground Fault <br />9 Surfactant Low <br />10 Battery Voltage Low <br />11 AC Power Failure <br />12 Door Tamper Switch <br />13 Test Mode <br />14 CORE Interlock Network <br />15 Fault on Hood in Interlock Network <br />16 Fault on PCU in Interlock Network <br />FIRE ALARM SYSTEM DRY CONTACTS. Termials <br />AL1 & AL2 make in FIRE. <br />To Building Fire Alarm <br />Panel <br />J9 <br />AL1 <br />AL2 <br />J3-7 <br />FIRE SYSTEM DRY CONTACTS. <br />Dry contacts will make C2 to AR2 when system is <br />armed. <br />RD-17-1 <br />C2 <br />AR214 AWG <br />YW <br />TROUBLE RELAY. Contact terminals TBC & TBL <br />make if there is trouble. Contact terminals TBC & <br />TOK make if the system is ok. <br />RD-20-1 <br />TBC <br />TBLTOK <br />YW <br />RD PS OR J4-9 <br />PS EWC-PRESSURE <br />Pressure Switch <br />PR RS <br />SW-05-1 <br />Test Armed <br />34YW RS-1 <br />RELEASE SOLENOID <br />BLBR <br />RD ORSW-05-2 <br />Test Armed34 J4-13 <br />SW-05 <br />ZB5AD2 <br />TEST/ARM Switch <br />RS2PRSW-05-1 <br />Test Armed <br />34YW <br />PS-1 <br />Pressure Switch <br />C <br />NC <br />NO QTY- <br />WH <br />PWS-01 <br />24VDC 18W POWER <br />24VDC Power Suppl <br />CA <br />CB <br />CC <br />AU1AU1AU2AU2 <br />TR2 <br />4996088 <br />Mountain Mike's ... <br />FACTORY <br />SC-111110FP <br />7/20/2021 <br />ECP #1-6 <br />Fire System #1 TANK Fire <br />Suppression - 4.0. Tank-based Fire <br />Protection System equipped with <br />Electronic Detection utilizing CORE <br />board as a Listed Release <br />Mechanism. Installed in Hood Utility <br />Cabinet with integral hood prewire <br />panel. <br />FS-1: MASTER <br />SHEET NO. <br />SCALE: <br />DWG.#: <br />DRAWN <br />DATE: <br /> BY: <br />REVISIONS <br />www.captiveaire.com ACCORDANCENo. 96BUILTNFPAWITHINSLIDTER4996088 <br />MASTER DRAWING <br />AH-86Mountain Mike's Pizza - Mountain House CAMountain House, CA, 95391Southern California Office3002 Dow Ave., Suite 410, Tustin, CA, 92780 PHONE: (714) 957-1500 FAX: (919) 227-5975 EMAIL: reg86@captiveaire.comCAPTIVEAIRE DRAWINGS <br />M-4.5 <br />PRINTED DATE: 07-21-2021PROJECT NAME/ADDRESS: <br />STAMP <br />@Mountain House <br />ARCHITECT <br />ARCH PROJECT #: <br />JOB NUMBER <br />DRAWN BY <br />SHEET CONTENT <br />SHEET NO <br />ISSUE DATE: <br />REVISIONS: <br />EM <br />21-___ <br />CHECK BY <br />ADR <br />ARCHITECTURE <br />GWA <br />1000 Corporate Center Drive <br />Suite 550 <br />Monterey Park, CA 91754 <br />tel: (626) 288-6898 <br />Member of The American Institute of Architects <br />REN. 04-30-2023