Laserfiche WebLink
SA N J O A Q U I N Environmental Health Department <br />—COUNTY <br />.,�Ulght bulbs and tubes shall be covered and completely enclosed in plastic safety shields <br />or the equivalent. (CRFC Section 114323) <br />8. Wastewater tanks shall have a minimum capacity that is 50 percent greater than the <br />potable water tanks. In no case shall the wastewater capacity be less than 7.5 gallons. <br />Where potable water for the preparation of a food or beverage is supplied, and additional <br />wastewater tank capacity equal to at least 15 percent of the water supply shall be <br />provided. <br />9. Potable water tanks shall be sufficient in volume to fulfill the required 5 gallon minimum <br />for hand washing. Facilities with limited food preparation must provide at least 15 <br />additional gallons of water for warewashing. For any preparation beyond limited food <br />preparation at least 25 additional gallons of water for warewashing and food preparation <br />must be provided. (CRFC Section 114217) <br />10.Tanks shall be adequately vented for flow. Water tank vents shall terminate in a <br />downward direction and shall be covered with 16 -mesh per square inch screen or <br />equivalent when the vent is in a protected area or a protective filter when the vent is in <br />an area not protected from windblown dirt and debris. (CRFC Section 114213) <br />Ze Mobile Food Facilities where nonprepackaged food is cooked, blended, or otherwise <br />prepared shall provide a warewashing sink with at least three compartments with two <br />integral metal drainboards. The dimensions of each compartment of the warewashing <br />sink shall be at least 12 inches wide, 12 inches long, and 10 inches deep, or large enough <br />to accommodate the cleaning of the largest utensil. Each drainboard shall be at least the <br />size of one of the sink compartments. The drainboards shall be installed with at least <br />one-eighth inch per foot slope toward the sink compartment, and fabricated with a <br />minimum of one-half inch lip or rim to prevent the draining liquid from spilling onto the <br />floor. (CRFC Section 114313) <br />.,dMechanical exhaust ventilation equipment shall be provided over all cooking equipment <br />as required to effectively remove cooking odors, smoke, steam, grease, heat, and <br />vapors. All mechanical exhaust ventilation equipment shall be installed and maintained <br />in accordance with the California Mechanical Code. Makeup air shall be provided the <br />rate of that exhausted [CRFC §114149.1 ] <br />14325. (b) A water heater with a minimum capacity of four gallons shall be provided for <br />mobile food facilities that have a warewashing sink. 5 C <br />I . Mobile food facilities shall have a clear, unobstructed height over the aisle -way portion <br />/ of the unit of at least 74 inches from floor to ceiling, and a minimum of 30 inches of <br />unobstructed horizontal aisle space. (CRFC Section 114321) <br />5 A second means of exit shall be provided in the side opposite the main exit door, or in <br />the roof, or the rear of the unit with an unobstructed passage of at least 24 inches by 36 <br />inches. The interior latching mechanism shall be operable by hand without special tools <br />or key. The exit shall be labeled "Safety Exit' in contrasting colors with letters at least <br />one inch high. (CRFC Section 114323) <br />2 of <br />