My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
1800
>
4500 - Medical Waste Program
>
PR0450006
>
COMPLIANCE INFO_2010-2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/30/2022 4:02:55 PM
Creation date
12/30/2022 3:55:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4500 - Medical Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2020
RECORD_ID
PR0450006
PE
4522
FACILITY_ID
FA0003761
FACILITY_NAME
ST JOSEPHS HOSPITAL
STREET_NUMBER
1800
Direction
N
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12718044
CURRENT_STATUS
01
SITE_LOCATION
1800 N CALIFORNIA ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\cfield
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
200
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4. You are now ready to start the decontamination cycle. Depress the green "start <br />cycle" on the control panel. The sterilizer will now achieve the following <br />functions: <br />A. Slowly inject steam until the internal temperature reaches 270 degrees F. <br />B. When reaching 270 degrees the sterilizer will run a 45 -minute <br />decontamination cycle and will continuously adjust and hold the internal <br />temperature to this level. <br />C. At the end of the cycle all steam is discharged from the sterilizer, cooled <br />to a liquid state, then discharged to the sanitary sewer. <br />WHEN THE CYCLE IS COMPLETE <br />1. At the end of each cycle check the recorder to make sure that the sterilizer <br />actually achieved 270 degrees for the full programmed cycle. The recorder chart <br />will be replaced every Monday morning prior to operating the steam sterilizer. <br />The used chart will be kept on file in the housekeeping office. If the sterilizer did <br />not achieve 270 degrees for the full programmed cycle, the housekeeping <br />supervisor will notify Maintenance who will check the unit and make the <br />appropriate repairs. The trash must then be run through a second cycle at the <br />required time and temperature. Action taken must be noted on the back of the <br />chart. <br />2. Unlatch the safety level over the locking ring. (You will be unable to open the <br />latch if the pressure is not fully equalized.) <br />3. The door can now be opened and the carts removed. Pull the carts out using the <br />metal hook and extension. The sterilizer is now ready for the next load. <br />Revised 12/2003 <br />Reviewed 7/13/2007 <br />Reviewed 6/2009 <br />Reviewed 3/12/2012 <br />Reviewed 311113 <br />
The URL can be used to link to this page
Your browser does not support the video tag.