Laserfiche WebLink
CLIENT: <br /> =t <br /> 22 223 <br /> 28 PRIMARY <br /> RETALIX ALLIED EC PUMP DISPa° N; <br /> POS ANDI BOX LOW #1 � <br /> BOX VOLTAGE <br /> TLS-350 26 PIB DISPENSER (SERIAL RS-485) DISP <br /> WIRING #2 <br /> 200 DISCONNECT <br /> beak Detecfion System Notes <br /> (PUMP INTERFACE BOARD) >- DISP <br /> 27 233 TYP n. <br /> CAT 1. WARNING: <br /> J-BOX MSM MONITOR SENSOR & PROBE WIRING IS INTRINSICALLY SAFE WIRING AND MUST BE SEPARATE <br /> OR DEBIT FROM ALL OTHER WIRING AND INSTALLED IN SEPARATE CONDUIT. MAXIMUM CABLE LENGTH <br /> CAT RS-485 BETWEEN MONITOR CONSOLE AND SENSORS IS 1,000 FEET. <br /> INTERFACE <br /> 2. CAUTION: <br /> 120 VAC WIRING MUST NOT BE CONNECTED TO LOW VOLTAGE CONNECTIONS. DAMAGE FROM <br /> MISWIRING IS NOT COVERED BY WARRANTY. INSTALLING CONTRACTOR TO BE HELD <br /> DB9 CONTROL RESPONSIBLE. <br /> SAM TERCOM/COM CABLE RS-485 PIC <br /> DEBIT q <br /> WIRING 3. INSTALL TANK MONITOR SYSTEM PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. <br /> ISCQN 4. USE BELDEN CABLE # 88760 OR APPROVED EQUAL FOR ALL SENSOR AND PROBE WIRING. <br /> DB9 CONTROL ARCO <br /> CABLE SHARED CONDUIT <br /> ETHERNET 5. RUN RIGID METAL CONDUIT FOR PROBE AND SENSOR WIRING FROM THE MONITOR CONSOLE <br /> 235 WIRING CAT 5 DISP (CAT 5 & <br /> TO THE INTRINSICALLY SAFE WIREWAY. CONDUIT MUST ENTER THE MONITOR WHERE LLC <br /> DISCONNECT1 INTERCOM) TO EACH KNOCKOUTS ARE PROVIDED. NO OTHER CONDUIT ENTRY IS PERMITTED. <br /> DB9 CONTROL >- DISPENSER <br /> CABLE < DISP (TYPICAL) 6. SPECIAL NOTE: IT IS THE INTENT OF THIS DESIGN THAT ANY DETECTED LEAK OR ANY FAILURE <br /> TERCOM/COM INTERCOM l #2 OF THE LEAK DETECTION SYSTEM, WILL RESULT IN THE INTERRUPTION OF ALL POWER TO THE <br /> 234 WIRING (BELDEN CABLE <br /> ea760) PRODUCT PUMPS. <br /> DISP <br /> TYP 7. CERTIFIED INSTALLERS- ALL MANUFACTURERS TRAINING REQUIREMENTS SHALL BE MET BY <br /> CONTRACTOR INSTALLING SENSORS/PROBES AND WIRING TO MONITORING SYSTEM. <br /> 8. IT IS THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO NOTIFY THE VEEDER ROOT <br /> LOW VOLTAGE DISPENSER WIRING DISCONNECTS DISTRIBUTOR FOR STARTUP. <br /> PRIMARY DISCONNECT: Power Integrity Corp. Model: DDS-8DM4WPE 0 <br /> NOTE: COM DISCONNECT (PIC): Power Integrity Corp. Model: DDS-8DB4C (IF PIC is located g SEE MANUFACTURERS WIRING DIAGRAM FOR SPECIFIC WIRING AND FURTHER INFORMATION. 11, �® <br /> OPTIONAL "MSI" POS CAN In Dispenser) 10. EACH TURBINE RELAY IS TO BE WIRED INTO THE MONITOR CONTROL SO THAT AN ACTIVATION <br /> INTERCOM DISCONNECT: Power Integrity Corp. Model: DDS-8DB4C OF TURBINE SIDE SUMP SENSOR OR ANNULAR SPACE SENSOR OR LLD WILL SHUT DOWN THE <br /> BE WIRED SIMILARLY ETHERNET DISCONNECT: Power Integrity Corp. Model: DDS-EWS8D(Wall Mount) TURBINE FOR THAT TANK. . <br /> or DDS-ERS8D (Rack Mount) 18215 72ND AVENUE SOUTH <br /> KENT, WA 98032 <br /> (425)251-6222 <br /> ARCO W A Y N E " NON - e " <br /> 9N0Nee9 4 T O R E T AU X PO S (425)251-8782 FAX <br /> SCALE: NTS CML ENGINEERING, LAND PUNNING, <br /> SURVEYING, ENVIRONMENTAL SERVICES <br /> NO. DATE REVISION DESCRIPTION <br /> 1 <br /> 2 <br /> 3 <br /> 4 <br /> o a L� <br /> CAT 5 C a � e � n sto � � a f i 0 n Gu ' d e IST-VFC MOTES VEEDER-ROOT TLS-350 NOTES <br /> 1. EXCESSIVE FORCE SHOULD NOT BE USED TO PULL IN NEW CABLE. PULL FORCE SHOULD NOT EXCEED REQUIREMENTS FOR THIS SYSTEM: ® WARNING: IN INSTALLATION AND USE OF THIS PRODUCT, <br /> 25 LBS. 1. TWO OR MORE VFC CONTROL BOXES WITH LATEST SOFTWARE. PLEASE CONTACT FE PETRO FOR COMPLY WITH THE NATIONAL ELECTRICAL CODE: FEDERAL, <br /> 2. CABLE SHALL NOT BE KINKED, KNOTTED, OR OTHERWISE DEFORMED DURING INSTALLATION. AVAILABILITY. STATE AND LOCAL CODES. IN ADDITION, TURN OFF POWER <br /> 2. VEEDER-ROOT TLS-350 WITH LATEST TLS-350 SOFTWARE. PLEASE CONTACT VEEDER-ROOT FOR AND TAKE OTHER NECESSARY PRECAUTIONS DURING <br /> 3. PROPER CABLE SUPPORT HARDWARE SUCH AS J-HOOKS SHALL BE USED TO PREVENT RIPPING OR AVAILABILITY. INSTALLATION, SERVICE AND REPAIR TO PREVENT PERSONAL z <br /> FRAYING OF CABLE. WHERE USED, STAPLES SHALL BE NON-METALLIC PLASTIC. STAPLE SHOULD BE 3. SET THE VFC WITH THE PLLD TRANSDUCER INSTALLED IN ITS PUMP TO BE THE MASTER VFC. INJURY, PROPERTY LOSS AND EQUIPMENT DAMAGE. SEAL <br /> LOOSE ENOUGH SUCH THAT CABLE JACKET IS NOT CRIMPED. 4. 18 AWG 3-WIRE SHIELDED COMMUNICATION CABLE (300 V MINIMUM) CONNECTING VFCS. Q�pF E S�/® <br /> 5. AN FE PETRO MODEL 65 PSI CHECK VALVE OR ANON-VENTED CHECK VALVE SHALL BE WARNING: DISCONNECT ALL POWER BEFORE MAKING AN <br /> 4. CABLE BUNDLES MAY BE SECURED WITH LOOSE FITTING WIRE TIE OR VELCRO TIE WRAPS. CABLES INSTALLED ON THE SLAVE PUMPS (IF USED). CONNECTIONS TO PREVENT DEATH, SERIOUS INJURY, <br /> SHALL NOT BE OVER TIGHTENED SUCH THAT CRUSH STRESS IS EVIDENT. 6. WIRE VFC CONTROLLERS ACCORDING TO THE LATEST FE PETRO TECHNICAL BULLETIN. EXPLOSION ELECTRICAL SHOCK. MONITOR MUST NEVER BE <br /> 7. INSTALLATION MANUALS FOR BOTH VEEDER-ROOT TLS-350 & FE PETRO VFC WILL BE AVAILABLE OPERATED UNLESS THE FRONT COVER IS CLOSED OVER THE C-0 <br /> 5. CABLE SHALL BE ROUTED TO PERMIT SWEEPING BENDS, NOT RIGHT ANGLES OR SHARP BENDS. CABLE DURING INSTALLATION. BARRIER TERMINALS IN THE INTRINSICALLY SAFE AREA. W C 1 rn <br /> RUNS SHALL BE INDIVIDUALLY SUPPORTED. <br /> BASIC OPERATION FOR THIS CONFIGURATION: NOTES: <br /> 6. A MINIMUM OF CABLE JACKET SHALL BE REMOVED WHEN TERMINATING. CABLE JACKET SHALL EXTEND <br /> AS CLOSE AS PRACTICAL TO THE TERMINATION POINT, LEAVING NO MORE THAN 3/4 INCH OF WIRE 1. THE VEEDER-ROOT TLS-350 SYSTEM MONITOR THE TANK PRODUCT LEVELS. 1. WIRING TO PROBES, SENSORS, & PLLD MUST BE SHIELDED MULTI-STRAND, GAS AND '�� / V 1 <br /> EXPOSED. 2. WHEN DEMAND FOR PRODUCT IS CALLED FOR, A 120 VAC HOOK SIGNAL FROM DISPENSER IS <br /> PRESENT, THE VEEDER-ROOT TLS-350 SYSTEM WILL TURN ON A PUMP ACCORDING TO THE PRODUCT OIL RESISTANT SIZES FROM AWG X18 TO AWG #14. BARRIER GROUND WIRING MUST BE � OF CA�-\F® <br /> 7. MAINTAIN TWISTED CONFIGURATION OF WIRE PAIRS TO WITHIN 1/2 INCH OF THE TERMINATION POINT. LEVEL IN THE TANKS, DICTATED BY CONSOLE CONFIGURATION. AWG ESI#12 OR LARGER. <br /> 3. WHEN DEMAND FOR PRODUCT RISES, MORE PEOPLE DISPENSING PRODUCT, WHICHEVER VFC IS IN <br /> THE LEAD POSITION CAN CALL FOR ADDITIONAL VFC TO TURN ON. 2. CONNECT WITH #12 AWG (OR LARGER) CONDUCTOR THE BARRIER GROUND TO THE <br /> 8. WIRES SHALL NOT BE SPLICED. DAMAGED CABLE SHALL BE REPLACED, NOT REPAIRED. 4. WHEN THE DEMAND FOR PRODUCT GOES AWAY, THE VEEDER-ROOT SYSTEM WILL PERFORM A LINE EARTH GROUND BUS AT THE POWER DISTRIBUTION PANEL. <br /> LEAK TEST USING THE VFC DESIGNATED AS THE MASTER ACCORDING TO VEEDER-ROOT'S LINE TEST 3. QDENOTES FIELD WIRING CONNECTION USING WATERPROOF CONNECTORS SUPPLIED <br /> 9. LEAVE APPROXIMATELY 18 INCHES OF SPARE WIRE AT OUTLET AND CONNECTION POINT. PROTOCOL. <br /> 5. IN THIS CONFIGURATION, IF THERE ARE ANY FAULTS IN THE SYSTEM THE WHOLE SYSTEM WILL BE WITH THE PROBE(S) AND SENSOR(S). <br /> 10. ENSURE ADEQUATE SEPARATION WHEN RUNNING CAT 5 CABLE PARALLEL TO POWER WIRING. CABLE SHUT DOWN. <br /> SHALL NOT BE ROUTED THROUGH SAME BORE HOLES AS POWER WIRING. WHERE POSSIBLE CAT 5 4. INTRINSICALLY SAFE WIRING SHALL BE INSTALLED IN ACCORDANCE WITH THE CURRENT <br /> CABLES SHOULD CROSS POWER WIRES AT 90 DEGREE ANGLES. MAINTAIN SEPARATION BETWEEN CABLE THE WIRING DIAGRAM IN FIGURE 1 SHOWS THE CONNECTIONS BETWEEN THE VEEDER-ROOT POWER BAY VERSION OF THE NEC AND NFPA CODES.. <br /> AND OTHER WIRING AS FOLLOWS: CONSOLE AND THE MASTER SLAVE VFCS. 5. TO MAINTAIN INTRINSIC SAFETY AND PROPER SYSTEM OPERATION, PROBE AND <br /> 1. FOLLOW ALL SAFETY AND INSTALLATION INSTRUCTIONS IN THE VEEDER-ROOT SITE PREP AND <br /> SENSOR WIRING MUST BE INSTALLED WITHIN SEALED CONDUIT. DEVELOPMENT INFORMATION: <br /> INSTALLATION INSTRUCTIONS FOR THE VEEDER-ROOT TLS-350. ARCO HT <br /> PURPOSE TYPE OF WIRE MIN. SEPARATION 2. FOLLOW ALL SAFETY AND INSTALLATION INSTRUCTIONS IN THE IST-VFC INSTALLATION AND OWNERS 6. ELECTRICAL RATING POWER INPUT - 120VAC, 50/60 HZ, 600 WATTS MAX. <br /> MANUAL FOR WIRING NOT SHOWN IN FIGURE 1. 30M a tmf /pm <br /> OPEN WIRING LESS THAN 300 VOLTS 2 INCHES 3. SET SW3 SWITCHES ACCORDING TO MASTER-SLAVE CONFIGURATION NOT FOR MASTER-SLAVE 7. REFER TO THE LATEST "SITE PREPARATION AND INSTALLATION INSTRUCTIONS,- MANUAL <br /> ALTERNATING CIRCUIT (M-S/AC). IF VFCS ARE SET IN M-S/AC THE PUMPS WILL NOT TURN ON IN A FOR ACTUAL LOCATION OF CONDUIT ENTRY INTO TLS-350 MONITOR. FUEL CANOPY <br /> POWER SUPPLY WIRE IN CONDUIT OR ARMORED OR PREDICTABLE MANNER. v� 65 M PD9 <br /> NON-METALLIC SHEATH CABLE/POWER NONE 4. CALIBRATE CONTROLLERS ACCORDING TO CALIBRATION INSTRUCTIONS IN IST-VFC INSTALLATION AND 8. REFER TO THE LATEST LINE LEAK DETECTOR "SITE PREPARATION AND INSTALLATION" <br /> GROUND WIRES OWNERS MANUAL. MANUAL. <br /> 4 INCHES <br /> RADIO & TELEVISION <br /> ANTENNA LEAD & GROUND WIRES ADDITIONAL NOTES: 9. RS-232 MODULE IS LOCATED IN THE COMMUNICATIONS COMPARTMENT AND MUST BE SITE ADDRESS: <br /> WITHOUT GROUNDED SHIELD ORDERED SEPARATELY. <br /> 1. FOR ADDITIONAL INFORMATION, REFERENCE THE LATEST VEEDER-ROOT SITE PREPARATION AND ESCALM AMUE <br /> SIGNAL & CONTROL WIRE OPEN WIRING NOT OVER 300 VOLTS NONE INSTALLATION MANUAL FOR INSTALLATION INSTRUCTIONS OF PLLD USING A MASTER/SLAVE 10. BONDING LOCKNUTS AND OR BONDING BUSHINGS SHALL BE USED AT ALL CONDUIT ©K 4JAv O <br /> CONFIGURATION. ENTRANCES TO THE TLS-350R ENCLOSURE AND AT ANY JUNCTION BOX/WIREWAYS IN THE ERCALGiAGA <br /> COMMUNITY TELEVISION SYSTEMS NON-HAZARDOUS AREA TO ENSURE POSITIVE CONDUIT GROUNDING. <br /> CATV CABLES COAXIAL CABLES WITH GROUNDED NONE 2. ANON-VENTED CHECK VALVE, VEEDER-ROOT PART NUMBER VR-330020-416, OR FE PETRO <br /> SHIELD MODEL 65-PSI CHECK VALVE MUST BE INSTALLED ON THE SLAVE TANK TURBINE TO ENSURE PROPER 11. SOFTWARE ENHANCEMENT MODULE REQUIRED (#330160-012) AND MUST BE FAC0 <br /> OPERATION OF SYSTEM AND PROVIDE ADEQUATE LINE LEAK PROTECTION. REFER TO THE LATEST FE ORDERED SEPARATELY. <br /> PETRO TECHNICAL SERVICE BULLETIN, FOR MORE SPECIFIC DETAILS. DESIGNED BY: ALLIANCE z&DM: <br /> TELEPHONE SERVICE 12. FOR 2 PUMPS IN SINGLE TANK OPERATION, PUMP SENSE MODULE REQUIRED A <br /> DROP WIRE AERIAL OR BURIED 2 INCHES 3. THE VEEDER-ROOT TLS-350 SYSTEM MUST BE PROGRAMMED USING THE CORRECT DISPENSER (#847490-204) AND MUST BE ORDERED SEPARATELY, IF USING PLLD, PUMP SENSE CHECKED BY: OV BP REPM: <br /> MODE. THE PROGRAMMER MUST SELECT THE MANIFOLDED ALTERNATE MODE IN THE PLLD SET-UP MODULE IS NOT <br /> ALLIANCEREQUIRED (ELECTRONIC LINE LEAK DETECTOR IS DOING THE PUMP DRAWN BY: AL ALLIANCE PM: <br /> SIGN NEON SIGNS AND ASSOCIATED WIRING SECTION. REFER TO THE LATEST VEEDER-ROOT SYSTEM SET-UP MANUAL FOR SPECIFIC PROGRAMMING SENSE). VERSION: PROJECT No <br /> FROM TRANSFORMER 6 INCHES INSTRUCTIONS. V-12a0 �� �� <br /> 4. THE VEEDER-ROOT TLS-350 MUST BE PROGRAMMED USING THE MANIFOLDED TANK SET-UP. THE 13. NO SPLICING OF PROBE/SENSOR WIRE EXCEPT AT THE DEVICE ITSELF. 12/14/2 <br /> FLUORESCENT LIGHTING FLUORESCENT LIGHTING WIRE 5 INCHES PROGRAMMER MUST ASSIGN THE MASTER TANK T-1 TO LINE LEAK DETECTOR Q-1. THE SLAVE TANK DRAV4NG TITLE: <br /> T-2 TO LINE LEAK DETECTOR Q-2. SPECIFIC PROGRAMMING QUESTIONS SHOULD BE DIRECTED TO 14. CONTRACTOR MUST COMPLY WITH ALL THE TRAINING REQUIREMENTS OF <br /> LIGHTNING SYSTEM LIGHTNING RODS AND WIRES 6 FEET VEEDER-ROOT TECHNICAL SUPPORT DEPARTMENT. VEEDER-ROOT. 9���E VEEDER-HOOT� <br /> 15. SPECIFIC PROGRAMMING FOR VEEDER ROOT TLS-350 CONSOLE SHALL BE OBTAINED NOTES <br /> FROM THE LOCAL ENVIRONMENTAL COMPLIANCE MANAGER. <br /> SHEET NO: <br /> NM ITEMS <br /> ON <br /> MATERIALSIC ISTSSHEETS M.5 3D01O <br /> XX & M.53.02 <br />