My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ESCALON
>
1329
>
1600 - Food Program
>
PR0542138
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/9/2023 5:17:38 PM
Creation date
1/12/2023 8:27:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0542138
PE
1617
FACILITY_ID
FA0000293
FACILITY_NAME
Pershing Holdings, Inc. DBA Esclon Arco
STREET_NUMBER
1329
STREET_NAME
ESCALON
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22510003
CURRENT_STATUS
01
SITE_LOCATION
1329 Escalon Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\lsauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
135
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CLIENT: <br /> 10 - MPD W/ ISD <br /> bp <br /> OFFICE MANAGER U 1 INTRINSICALLY-SAFE AREA i <br /> BGE FLEA®�® <br /> REGULAR <br /> k <br /> GROUND ❑® 9 <br /> TURBINE SUMP <br /> MODULE TYPE: SMART SENSORS <br /> VEEDER ROOT (MASTER) POSITION RECORD: ISD DISPENSER SENSORS & DIESEL VACUUM SENSORS <br /> TLS-350 LEAK <br /> DETECTION MONITOR � 1— SPARE 5— SPARE <br /> 2— SPARE 6— SPARE <br /> PWR IS 13, <br /> D,E,F,Fy F 3— SPARE 7— SPARE <br /> 4— SPARE 8— SPARE <br /> 1 MODULE TYPE: SMART SENSORS <br /> PREMIUM {5} BELDEN <br /> CABLE 88760 POSITION RECORD: ISD DISPENSER SENSORS <br /> TANK 7 PRESSURE 1- SITE VAPOR FLOW <br /> 2- DISPENSER 12FLOW SENSOR 6- DISPENSER 9/- DISPENSER 10 FLOW <br /> FILL SUMP 3- DISPENSER 3/4 FLOW 7- DISPENSER 11 FLOW <br /> 2 12 4- DISPENSER 5 6 FLOW 8- SPARE <br /> B, ,F9 �,C 9 <br /> MODULE TYPE: SMART SENSORS VACUUM w PRESS. <br /> F T <br /> TURBINE SUMP 000 1 - ULR 1 PRODUCT & MANIFOLD LINES 5- ULP <br /> 0 6 2- ULR 1 VENT LINE 6-SPAREENT LINE <br /> 0 0 ARCO <br /> 3— VAPOR LINE LOCATED IN ULR 1 7—SPARE 8?WM am I"Famm LLC <br /> 1" C, (8) BELDEN CABLE 88760 1"C, (4) BELDEN CABLE 88760 1"C, 4— ULP PRODUCT LINE 8— AMBIENT CONDITION SENSOR <br /> 1- C, (9) BELDEN CABLE 88760 (2) BELDEN MODULE TYPE: INTERSTITIAL SENSOR INTERFACE <br /> CABLE 88760 POSITION RECORD: UDC & VENT SUMP SENSORS STACKED, 2 PER CHANNEL <br /> FILL SUMP 00 J 1-SPARE 5- SPARE V <br /> 0 2-SPARE 6- SPARE <br /> 9C <br /> 3-VENT TRANSITION SUMP & HYDROSTATIC 7- SPARE <br /> 1"C, (2) BELDEN CABLE 88760 ' A 4-VAPOR CANISTER AT VENTS 8- SPARE <br /> 0 <br /> MODULE TYPE: INTERSTITIAL SENSOR INTERFACE _= <br /> POSITION RECORD: UDC SENSORS STACKED, 2 PER CHANNEL <br /> 1—DISPENSER # 1/2 SUMP & HYDROSTATIC 5—DISPENSER 9/10 SUMP & HYDROSTATIC <br /> 2—DISPENSER # 3/4 SUMP & HYDROSTATIC 6—DISPENSER 11/12 SUMP & HYDROSTATICS ` <br /> 3—DISPENSER # 5/6 SUMP & HYDROSTATIC 7— " <br /> 4— DISPENSER # 7/8 SUMP & HYDROSTATIC 8—SPARE <br /> (1) 1" C, (3) BELDEN CABLE 88760 HYDROSTATIC RESERVOIR CROUSE—HINDS EYS MODULE TYPE: INTERSTITIAL SENSOR INTERFACE 9� G <br /> (SEAL—OFF) OR EQUAL. POSITION RECORD: TANK SUMP SENSORS STACKED, 2 PER CHANNEL <br /> (1) 1" C, W/ PULL ROPE B'E <br /> (TYP ) HYDROSTATIC RESERVOIR 3 1— ULR 1 TURBINE SUMP & HYDROSTATIC 5—SPARE 18215 72ND AVENUE SOUTH <br /> 2— ULR 1 FILL SUMP & HYDROSTATIC 6—SPARE <br /> 3— ULP TURBINE SUMP & HYDROSTATIC 7—SPARE KENT, WA 98032 <br /> SEE TANK FUELING SITE PLAN FOR SPECIFIC TANK LAYOUT 4— ULP FILL SUMP & HYDROSTATIC 8—SPARE (425)251-6222 <br /> VENT STACK W/ VENT MODULE TYPE: PROBE INTERFACE INTERSTITIAL SENSOR COMBO. MODULE (425)251-8782 FAX <br /> TRANSITION SUMP POSITION RECORD: TANK LEVEL GAUGES TANK ANNULAR <br /> A SENSOR IN HYDROSTATIC RESERVOIR (ANNULAR SPACE OF TANKS) 2 1- ULR 1 ATG 1- ULR 1 TANK ANNULAR CML ENGINEERING, LAND PLANNING, <br /> SURVEYING, ENVIRONMENTAL SERVICES <br /> 8 STANDARD LIQUID SENSOR IN TURBINE/FILL/VENT SUMPS 2- ULP ATG 2- ULP TANK ANNULAR <br /> 3-SPARE 3- SPARE NO. DATE REIdSION DESCRIPTION <br /> C TANK LEVEL GAUGE IN PILL SUMP 4-SPARE 4- SPARE <br /> ngl ConduH <br /> Schematic <br /> MODULE TYPE: PLLD INTERFACE MODULE 1 <br /> Tankft �o ® PRESSURIZE® LINE LEAD DETECTOR IN TURBINE SUMP (PLL®} POSITION RECORD: TURBINE PLLD 2 <br /> H` E — SENSOR IN SUMP HYDROSTATIC RESERVOIR 1 1 -ULR 1 5- SPARE <br /> 2-ULP 6- SPARE 3 <br /> F - VACUUM SENSOR IN TANK SUMP ANNULAR SPACE OF PRODUCT LINE <br /> SCALE: N.T.S. 3-SPARE <br /> 4-SPARE <br /> 5 <br /> GROUND 9R R 0 <br /> NEUTRAL BUS ISOLATED NON—HAZARDOUS AREA HAZARDOUS AREA Q <br /> o PUMP CONTROL FROM GROUND <br /> ULR = UNLEADED REGULAR <br /> zELECTRICAL PANEL <br /> FROM DISPENSER ISOLATION BONDING SCREW REMOVED ULP = UNLEADED PREMIUM <br /> RELAYS PER NEC 2 0-61(b) RIGID CONDUIT FROM DISPENSERS Q <br /> SWITCHED HOT 9 <br /> ( Tao OR aao VAC. ) ELECTRICALLY ISOLATED LOW VOLTAGE SIDESENSOR LOCATED "VEEDER—ROOT" TLS-350 w/ PRINTER MODEL #VR-848290-122 (WITH THE FOLLOWING CONFIGURATION) <br /> PUMP IN (PI) GROUND BUS (INSULa,TEDIN SUMP <br /> FROM THE PANEL VIA A JUNCTION BOX EXPLOSION PROOF J—BOX HYDROSTATIC (1) VR-330160-160 RISK MANAGEMENT SOFTWARE 11 <br /> NON—CONDUCTIVE MOUNTING) (CLASS 1, DlvisioN 1) SUMP (1) VR-330404-010 WAYNE DIM MODULE <br /> F.E. PETRO "IST—VFC" + uTE + 12 <br /> REMOTE CONTROL BOX z METALLIC CONDUIT, DO NOT SENSOR <br /> ROUTE THROUGH AC TROUGH (1) VR-848703-010 WAYNE DIM INSTALL KIT SEAL <br /> 1 VR-330020-425 ETHERNET TCP/IP INTERFACE MODULE OFESS/ Z"�dJ1( <br /> 00 TLS-3508 MONITOR . b SENSOR LOCATED TYPICAL AT O / <br /> QR ® <br /> 200-250V CONDIITONED oPnoNAL a HP wnRLuc � w SE - IN SUMP DISPENSERS & adv® Me T <br /> POWER SUPPLY PROVIDED 3 PH L2 �, NOTE 7 (1) VR-331943-002 NVMEM2 MEMORY UPGRADE @� \� <br /> THROUGH PUMP 1 P CPMNAL SMMH(SM) in ° ON M.55.3.3o AT VENT SUMP\ L1 o SUMP h <br /> ELECTRICAL DISTRIBUTION ® MR 2—IN-1 1 VR-330162-XXX SEM UPGRADE <br /> CONTROL CENTER GN ® ® ® ® SENSOR SENSOR ( ) <br /> 0� w,1 _ " 80X (1) VR-329356-005 COMBO INTERFACE MODULE - FOUR INPUT PROBE INTERFACE rn <br /> 115V o S° ( � AC NEUTRAL ° 0000®®®®®®®®®0 0 WITH FOUR INPUT INTERSTITIAL LIQUID SENSOR INTERFACE 5 <br /> NEUTRAL AC LINE ® ® ,= 11 <br /> EXPLOSION PROOF J—BOX MAG PROBE LOCATED <br /> (CLASS 1, DIVISION 1) IN FILL SUMP (1) VR-329359-001 FOUR RELAY OUTPUT MODULE <br /> o ® +o x TAN K <br /> RIGID CONDUIT ,—,-�—� . - _ Ll <br /> LEVEL (1) VR-330280-001 BIR PROTOCOL DIM \� <br /> cND o ®® GAUGE (1) VR-330843-001 6 INPUT PLLD MODULE ��F 01 V <br /> ® °® o <br /> 6LK (2) VR-330374-001 3 OUTPUT PLLD CONTROLLER MODULE ®� Ci���� <br /> ORG TO MOTOR NEUTRAL 15A ® ® SENSOR LOCATED HYDROSTATIC <br /> RED 120V L BREAKER <br /> IN FILL/TURBINE SUMP (1) VR-332250-001 SEVEN INPUT W/ PRESS. SMART CARD <br /> EXPLOSION PROOF J—BOX LEAK <br /> ° . . .. ® (CRSS 1, DIVISION 1) DETECTION (2) VR-329356-004 EIGHT INPUT SMART CARD <br /> 0 <br /> ®� + + <br /> See "Pump Control Wiring" and "system description" 0 0 0 FILL/TURBINE (3) VR-329358-001 EIGHT INPUT INTERSTITIAL/LIQUID SENSOR INTERFACE MODULE <br /> TO for specific wiring connections and SUMP <br /> SUBMERSIBLE speed/dip switch settings. Li. <br /> STANDARD <br /> PUMP 0 O SENSOR LOCATED <br /> LLD MANUAL IN TURBINE FILL SUMPLEAK <br /> NO. 576013-902 REV. "H" OR HIGHER "" <br /> ® e®®®00 0 .00 00 ®® � DETECTION <br /> ILIy 2-IN-1 <br /> SENSOR TURBINE/FILL <br /> 0000®' BOX SUMP <br /> rr�r^ _ ,a� SINGLE FLOAT SENSOR TYPICAL AT <br /> ® ® c *' - EXPLOSION PROOF J—BOX IN HYDROSTATIC DEVELOPMENT INFORMATION: <br /> PUMP OUTPUT Po ❑Q TAN K <br /> F.E. PETRO "IST—VFC" ®®® ® m® (CLASS 1, DIVISION 1) RESERVOIR LEAK <br /> REMOTE CONTROL BOX <br /> DETECTION ARCO <br /> MASTER REGULAR <br /> 3HYDROSTATIC <br /> r <br /> oPrmNa�s HP WIRINGRIGID CONDUIT SEE NOTE 10 --•• c RESERVOIR <br /> 200-250V CONDITIONED SPT POLE s off ON M.5.3.30 --" - <br /> PO <br /> wER SUPPLY 3 PH L2 (( �MGN � FUEL CANOPY <br /> PROVIDED THROUGH 1 P L1 �oR ( EXPLOSION PROOF J—BOX PLLD SENSOR <br /> PUMP ELECTRICALMH <br /> i1 \I� (CLASS 1, DIVISION 1) IN TURBINE SUMP PRESSURE <br /> DISTRIBUTION CONTROL ON SO PrMRE SEI ALL svorcHEs <br /> CENTER Om (.9> OF <br /> SERIAL ADDRESS OPTIONAL AUDIBLE HORN +o LINE LEAK <br /> ,v ;W-SLAVE POSMON <br /> R _ TURBINE <br /> r CDBI&RATION PER <br /> NEUTRAL TABLE 5 OF IST-VEC ® SUMP SITE ADDRESS: <br /> INSTALLATION <br /> asrNER's MAN AL <br /> NOTE: <br /> LLI DIAGRAM SHOWN IS BASED ON A22K E �I AVRUE <br /> s Co UNIOCAMON MASTER—SLAVE IST SET UP. IF AN ALTERNATE SPARE CABLE <br /> GND (oPn0 WMEMN) SINGLE MASTER IST SET UP IS USED, REFER EXPLOSION PROOF J—BOX VACUUM SENSOR o FLIWA <br /> BLK I I I TO VEEDER ROOT PROGRAMMING MANUAL, & (CLASS 1, DIVISION 1) IN TURBINE SUMPVACUUM L CA <br /> 0 K TO MOTOR THE FE PETRO TECHNICAL BULLETIN DATED + t SENSOR <br /> D JUNE 12, 2001, FOR VEEDER—ROOT TLS-350 <br /> RE <br /> & FE PETRO INTERFACE WIRING. IN TURBINE <br /> SUMP FA ffY 0 TBD <br /> RIGID AL <br /> DESIGNED BY: ALLIANCE Z&sDM: <br /> CONDUIT EXPLOSION PROOF J—BOX SENSOR LOCATED CHECIO BY: BP REPM: <br /> FROM TANKEACH (CLASS 1, DIVISION 1) IN DISPENSER CABINETVAPOR TYPICAL AT DRAWN BY: OV ALLIANCE PM:+o MM FLOW DISPENSER AL <br /> RIGID CONDUIT METER VERSION: V-12.0 PROJECT NO: <br /> FROM EACH 17223 <br /> DISPENSER �,° 12114/P-M5 <br /> EXPLOSION PROOF J—BOX SENSOR LOCATED <br /> DRAwiNG TITLE: <br /> (CLASS 1, DIVISION 1) IN DISPENSER CABINET AT ONLY ONE <br /> ELECTRICAL FUELING DETAILS <br /> SENSOR WIRING SHALL BE INTRINSICALLY +®raFmE VAPOR DISPENSER <br /> SAFE WIRING BELDEN CABLE 88760 FOR PRESSURE FOR VEEDER MOOT <br /> EACH SENSOR/PROBE (TYP.) SENSOR POWERS/DISTRIBD ITIION CENTER <br /> (20K/12I/10K 6K TANKS) <br /> --- SHEET NO: <br /> TO I STS <br /> Typical Master/Suva 9ST Mein Diagram HiGH VOLTAGE <br /> � � m WIREwAv <br /> NOTE: INDICATES ITEMS FOUND ON MATERIALS Mm5m3u27 <br /> SCALE: NTS XX LIST SHEETS M.5.3.01 & M.5.3.02 <br />
The URL can be used to link to this page
Your browser does not support the video tag.