Laserfiche WebLink
M. Indirect Waste Receptors: <br />® 1. CRFC 114193 <br />(a) All steam tables, ice machines and bins, food preparation sinks, warewashing sinks, display cases, <br />walk-in refrigeration. units, and other similar equipment that discharge liquid waste shall be drained by <br />means of indirect waste pipes, and all wastes drained by them shall discharge through an airgap into a <br />floor sink or other approved type of receptor_ <br />(b) Drainage from reach -in refrigeration units shall be conducted in a sanitary manner to a floor sink or other <br />approved device s by an indirect connection or to a properly installed and functioning evaporator. <br />(c) Indirect waste receptors hall be located to be readily accessible for inspection and cleaning. <br />(d) Warewashing machines may be connected directly to the sewer immediately downstream from a floor <br />drain, or they may be drained through an approved indirect connection. <br />(e) Warewashing sinks in use on January 1, 1996, that are directly plumbed may be continued in use. This <br />section does not require warewashing sinks to be indirectly plumbed when the local building official <br />determines that the sink should be directly plumbed. <br />] 2. CRFC 114193.1 <br />An air gap between the water supply inlet and the flood level rim of the plumbing fixture, equipment, or <br />nonfood equipment shall be at least twice the diameter of the water supply inlet and may not be less than one <br />inch. <br />N. Sewage Disposal., Grease Traps and Interceptors: <br />IN 1. CRFC 114197 <br />Liquid waste shall be disposed of through the approved plumbing system and shall discharge into the public <br />sewerage or into an approved private sewage disposal system. <br />2. CRFC 114201 <br />(a) If provided, a grease trap or grease interceptor shall not be located in a food or utensil handling area unless <br />specifically approved by the enforcement agency. <br />(b) Grease traps and grease interceptors shall be easily accessible for servicing. <br />(c) Notwithstanding subdivision (a), those food facilities approved with a grease trap or grease interceptor that <br />are in operation 'before the effective date of this part are not required to comply with this section. <br />NOTE: Check with local health, building, sanitary -or public works agencies for information or regulations <br />regarding special sewerage, grease trap and interceptor requirements. <br />IV. Ventilation: <br />® 1. Mechanical exhaust ventilation systems and make-up air systems shall conform to the provisions of the <br />California Mechanical Code. <br />CRFC 114149 <br />(a) All areas of a food facility shall have sufficient ventilation to facilitate proper food storage and to provide a <br />reasonable condition of comfort for each employee, consistent with the job performed by the employee. <br />(b) Toilet rooms shall be vented to the outside air by means of an openable, screened window, an air shaft, or a <br />fight -switch -activated exhaust fan, consistent with the requirements of local 'building codes.. <br />A. Exhaust Hoods and Ducts: <br />J 1. CRFC 114149.1 <br />(a) Mechanical exhaust ventilation equipment shall be provided over all cooking equipment as required to <br />effectively remove cooking odors, smoke, steam, grease, heat, and vapors. All mechanical exhaust <br />ventilation equipment shall be installed and maintained in accordance with the California Mechanical Code, <br />except that for units subject to Part 2 (commencing with Section 18000) of Division 13, an alternative code <br />adopted pursuant to Section 18028 shall govern the construction standards. <br />(b) Restricted food- service facilities shall be exempt from subdivision (a), but shall still provide ventilation to <br />remove gases, odors, steam, heat, grease, vapors and smoke from the food facility. In the event that the <br />enforcement officer determines that the ventilation must be mechanical in nature, the ventilation shall be <br />accomplished by methods approved by the enforcement agency. <br />(c) This section shall not apply to cooking equipment when the equipment has been submitted to the local <br />enforcement agency for evaluation, and the local enforcement agency has found that the equipment does not <br />produce toxic gases, smoke, grease, vapors, or heat when operated under conditions recommended by the <br />manufacturer. The local enforcement agency may recognize a testing organization to perform any necessary <br />evaluations. <br />(d) Makeup air shall be provided at the rate of that exhausted. <br />EHD 1&01 11 PLAN CHECK GUIDE <br />811114 <br />