® 2. CRFC 114149.2 <br />(a) Every hood shall be installed to provide for thorough cleaning of all interior and exterior surfaces, including, <br />but not limited to, the hood, filters, piping, lights, troughs, hangers, flanges, and exhaust ducts. <br />(b) Exhaust ventilation hood systems in food preparation and warewashing areas, including components such as <br />hoods, fans, guards, and ducting, shall be designed to prevent grease or condensation from draining or <br />dripping onto food, equipment, utensils, linens, and single -use articles. <br />(c) Filters or other grease extracting equipment shall be designed to be readily removable for cleaning and <br />replacement if not designed to be cleaned in place. <br />(d) Every joint and seam shall be substantially tight. No solder shall be used, except for sealing a joint or seam. <br />(e) When grease gutters are provided they shall drain to a collecting ,receptacle fabricated, designed, and <br />installed to be readily accessible for cleaning. <br />(f) Exhaust hood ducting shall meet the following requirements: <br />(1) All seams in the duct shall be completely tight to prevent the accumulation of grease. <br />(2) The ducts shall have sufficient clean -outs to make the ducts readily accessible for cleaning. <br />(3) All ducts in the exhaust system shall be properly sloped. <br />(4) Intake and exhaust air ducts shall be cleaned and filters changed so they are not a source of <br />contamination by dust, dirt, and other materials. <br />V. Equipment Requirements: <br />A Equipment and Utensils <br />1. CRFC 114130 <br />(a) Equipment and utensils shall be designed and constructed to be durable and to retain their characteristic <br />qualities under normal use conditions. <br />(b) Except as specified in subdivision (c), all new and replacement food -related and utensil -related equipment <br />shall be certified or classified for sanitation by an American National Standards Institute (ANSI) accredited <br />certification program. In the absence of an applicable ANSI certified sanitation standard, food -related, and <br />utensil -related equipment shall be evaluated for approval by the enforcement agency. <br />(c) Restricted food service facilities need not comply with subdivision (b), depending on the extent of the food <br />service activities, and if the enforcement officer determines that the equipment meets the characteristics of <br />subdivision (a). <br />(d) All new and replacement electrical appliances shall meet applicable Underwriters Laboratories standards for <br />electrical equipment as determined by an ANSI accredited certification program. <br />® 2. CRFC 114130.1 <br />Materials that are used in the construction of utensils and food -contact surfaces of equipment shall not allow the <br />migration of deleterious substances or impart colors, odors, or tastes to food and under normal use conditions <br />shall be safe, durable, corrosion -resistant, and nonabsorbent, sufficient .in weight and thickness to withstand <br />repeated warewashing, finished to have a smooth, easily cleanable surface, and resistant to pitting, chipping, <br />crazing, scratching, scoring, distortion, and decomposition. <br />t 3. CRFC 114130.3 <br />(a) Multiuse food -contact surfaces shall be all of the following: <br />(1) Smooth. <br />(2) Free of breaks, open seams, cracks, chips, inclusions, pits, and similar imperfections. <br />(3) Free of sharp internal angles, corners, and crevices. <br />(4) Finished to have smooth welds and joints. <br />(5) Except as specified in subdivision (b), accessible for cleaning and inspection by one of the following <br />methods: <br />(A) Without being disassembled. <br />(B) By disassembling without the use of tools. <br />(C) By easy disassembling with the use of handheld tools commonly available to maintenance and <br />cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches. <br />® 4. CRFC 114169 <br />(a) Equipment that is fixed because it is not easily movable shall be installed so that it is: <br />(1) Spaced to allow access for cleaning along the sides, behind, and above the equipment. <br />(2) Spaced from adjoining equipment, walls, and ceilings a distance of not more than one millimeter or one <br />thirty-second inch. <br />(3) Sealed to adjoining equipment or walls, if the equipment is exposed to spillage or seepage. <br />(b) Except as specified in subdivisions (c) and (d), floor -mounted equipment that is not easily movable shall be <br />sealed to the floor or elevated on legs that'provide at least a six-inch clearance between the floor and the <br />equipment. <br />EHD 16.01 12 PLAN CHECK GUIDE <br />8!1/14 <br />