Laserfiche WebLink
SAN JOAQUIN <br />CCUNT <br />Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />COUNTRY CLUB MOBIL CIRCLE K <br />2575 COUNTRY CLUB BLVD, STOCKTON <br />January 18, 2023 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />208 <br />CCR 2716(a -e) Failure to comply with the designated operator inspection requirements. <br />1) OBSERVATION: The designated operator reports were missing the name of the owner/operator. <br />REGULATORY GUIDANCE: Within 48 hours of the completion of the designated UST operator visual inspection, <br />the designated operator shall sign and provide the owner or operator with a copy of the inspection report. Within 72 <br />hours of being provided a signed copy of the report, the owner or operator shall provide a description of each <br />corrective action taken or to be taken and shall sign and date the report, acknowledging the identified compliance <br />issues. <br />CORRECTIVE ACTION: Ensure all designated operator inspection reports are completed and signed within the <br />required time frame in the future. <br />------------------------------------------------------------------------------------ <br />2) OBSERVATION: The designated operator failed to check and note all required items on the visual inspection <br />reports. The incorrect and missing information included the following from the inspection reports: <br />-The designated operator reports were missing the owner/operator description of corrective actions regarding the <br />multiple active smart sensor alarms. <br />REGULATION GUIDANCE: During the visual inspection, the designated operator shall check that all required <br />testing and maintenance for the UST system have been completed and shall check all required items on the report. <br />CORRECTIVE ACTION: Ensure that designated operators performing visual inspections at this facility are including <br />all of the required information on the reports. <br />This is a repeat violation, Class II. <br />210 <br />CCR 2715(c) Failure to provide initial training, train every 12 months, and have a trained employee present. <br />OBSERVATION: The designated operator employee training for Khan was not performed. <br />REGULATION GUIDANCE: The designated operator shall train facility employees in the proper operation and <br />maintenance of the UST system at least once every 12 months. The training shall be conducted before the <br />individual performs the duties of a facility employees. The training shall include, but is not limited to: <br />1. Operation of the UST system in a manner consistent with the facility's best management practices <br />2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br />3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br />4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br />Initial training shall also include a site-specific practical demonstration that provides both sharing information and <br />evaluating knowledge for responding to emergencies, leak detection, monitoring alarms, spills and overfills. At least <br />one of the facility employees present during operating hours shall have current training. <br />CORRECTIVE ACTION: Ensure that employees have been trained by the designated operator, maintain the list on <br />site, and submit a copy of the training records to the EHD. <br />This is a Class II violation. <br />FA0006439 PR0231070 SCO01 01/18/2023 <br />EHD 23-01 Rev. 12/06/2021 Page 7 of 10 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />