SAN JOAQUIN <br />CCUNT <br />Environmental Health Department <br />AMENDED <br />1/30/2023 <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />COUNTRY CLUB MOBIL CIRCLE K <br />2575 COUNTRY CLUB BLVD, STOCKTON <br />January 18, 2023 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />302 <br />CCR 2630(d), 2641(a) Leak detection equipment not installed/maintained/located to detect leaks at earliest <br />opportunity. <br />1) OBSERVATION: <br />-The VR 208 sensor in UDC 3/4 was raised approximately 4 inches off the lowest point of the sump and not located <br />to detect a leak at the earliest opportunity. <br />-The VR 208 sensor in UDC 7/8 was raised approximately 1 inch off the lowest point of the sump and not located to <br />detect a leak at the earliest opportunity. <br />REGULATION GUIDANCE: Monitoring equipment shall be maintained to be able to detect a leak at the earliest <br />possible opportunity. <br />CORRECTIVE ACTION: The sensor was relocated to the lowest point of the sump by the service technician. <br />Ensure that all monitoring equipment is maintained and located to detect a leak at the earliest opportunity. <br />------------------------------------------------------------------------------------ <br />2) OBSERVATION: The smart sensors were found to be in alarm since [DATE] and actions have not been taken to <br />address the alarm. <br />REGULATION GUIDANCE: All monitoring equipment shall be maintained to be able to detect a leak at the earliest <br />possible opportunity. <br />CORRECTIVE ACTION: Immediately contact a properly licensed, trained, and certified contractor to address the <br />alarm under permit and inspection of the EHD. <br />This is a Class II violation. <br />307 <br />HSC 25290.1(c3), 25290.2(c3) Failure to keep water out of the secondary containment system (post -Jul 2003). <br />OBSERVATION: <br />- Approximately 15 gallons of water was observed in the 87 fill sump. <br />- Approximately 15 gallons of water was observed in the diesel fill sump. <br />- Approximately 2 cups of water was observed in UDC 1/2. <br />REGULATION GUIDANCE: Secondary containment shall be constructed to prevent any water intrusion into the <br />system by precipitation, infiltration, or surface runoff. <br />CORRECTIVE ACTION: The service technician removed all of liquid from the sumps and returned the sensor to its <br />proper location. Immediately contact a properly licensed, trained, and certified contractor to address the water <br />intrusion into the sumps under permit and inspection of the EHD. <br />This is a repeat violation, Class II. <br />FA0006439 PR0231070 SCO01 01/18/2023 <br />EHD 23-01 Rev. 12/06/2021 Page 9 of 10 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />