My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2575
>
2300 - Underground Storage Tank Program
>
PR0231070
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/17/2025 2:17:44 PM
Creation date
1/12/2023 9:36:55 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0231070
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0006439
FACILITY_NAME
COUNTRY CLUB MOBIL CIRCLE K
STREET_NUMBER
2575
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
2575 COUNTRY CLUB BLVD STOCKTON 95204
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN <br />CCUNT <br />Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />COUNTRY CLUB MOBIL CIRCLE K <br />2575 COUNTRY CLUB BLVD, STOCKTON <br />March 15, 2023 <br />Single -Walled Non -Pressurized Piping <br />404 <br />CCR 2643(e), 2661(f) <br />Failure to conduct 0.1 gph test on single -walled gravity piping biennially or post repair (pre -1984) <br />❑ V ❑ R ❑ COS <br />Other Violations <br />2010 <br />See below <br />Unlisted General violation <br />❑ V ❑ R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />112 <br />CCR 2638, 26410), 2715(f) Failure to have properly qualified service technician test leak detection equipment every <br />12 months. <br />OBSERVATION: The annual monitoring system certification and leak detector testing were last performed on <br />1/28/22 and were due by January 2023. Testing has not been completed and is two months past due. Smart <br />sensors (vacuum sensors) have not been tested. <br />REGULATION GUIDANCE: These tests are required once every 12 months. <br />CORRECTIVE ACTION: Immediately schedule these tests and provide 48 hours notification to the EHD. Please be <br />aware that all EHD staff time associated with a follow up inspection will be billed at our current hourly rate ($156). <br />This is a repeat violation, Class II. <br />302 <br />CCR 2630(d), 2641(a) Leak detection equipment not installed/maintained/located to detect leaks at earliest <br />opportunity. <br />OBSERVATION: <br />-The annular spaces of both tanks were observed to have no vacuum. According to the technician, the sensor is not <br />functional and is unable to pull vacuum on the tank annular spaces. The -420 liquid sensors were tested and no <br />vacuum was observed when the caps were removed. <br />-S1, S2, S3, S4, S5 vacuum sensors were in no vacuum alarm at the time of inspection. According to the <br />technician, the site is using Blueline penetration boots in the UDCs that are deteriorating, causing the secondary <br />containment to leak and creating no vacuum alarms for a smart sensors. <br />REGULATION GUIDANCE: All monitoring equipment shall be maintained to be able to detect a leak at the earliest <br />possible opportunity. <br />CORRECTIVE ACTION: Immediately contact a properly licensed, trained, and certified contractor to address the <br />alarm under permit and inspection of the EHD. <br />This is a repeat violation, Class II. <br />FA0006439 PR0231070 SC333 03/15/2023 <br />EHD 23-01 Rev. 12/06/2021 Page 4 of 6 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.