My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COVSFU5E5 (2)
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
8115
>
2500 – Emergency Response Program
>
COVSFU5E5 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2023 4:06:58 PM
Creation date
1/20/2023 4:03:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2500 – Emergency Response Program
RECORD_ID
COVSFU5E5
PE
2546
STREET_NUMBER
8115
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
FRENCH CAMP
Zip
95231
APN
19317003
ENTERED_DATE
5/23/2022 12:00:00 AM
SITE_LOCATION
8115 S EL DORADO ST
RECEIVED_DATE
5/23/2022 12:00:00 AM
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\ymoreno
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN <br /> Environmental Health Department <br />AMENDED <br />6/22/2022 <br />Aboveground Petroleum Storage Act Inspection Report <br />Facility Name: <br />J & L MARKET <br />Facility Address: <br />8115 S EL DORADO ST, FRENCH CAMP <br />Date: <br />May 23, 2022 <br />Qualified Facility - Tier I <br />402 CFR 112.6(a)(2) Owner of Tier! Qualified Facility failed to self certify technical amendment EV oR oCOS <br />403 CFR 112.6(a)(3)(i) Tier I Plan failed to predict direction/rate of flow/total quantity of oil potentially discharged DV oR oCOS <br />404 CFR 112.6(a)(3)(ii) No adequate 2CT for bulk containers, or mobile storage containers not located to prevent discharge oV oR oCOS <br />405 CFR 112.6(a)(3)(iii) Failed to provide systems to prevent overfills or to routinely test them (Tier I facility) oV oR oCOS <br />406 CFR 112.6(a)(3)(iii) Tier I Plan failed to adequately describe the overfill prevention methods for each container oV oR oCOS <br />Qualified Facility - Tier II <br />501 CFR 112.6(a)(1), <br />112.6(b) <br />Tier II Qualified Facility Plan not certified by the owner or a PE, as required oV oR o COS <br />502 CFR 112.6(b)(2) Tier II Qualified Facility Plan technical amendment not certified by the owner or a PE oV ER oCOS <br />503 CFR 112.6(b)(3), <br />112.6(b)(4) <br />Failure to have a PE certify in writing alternative measures for a Tier II Qualified Facility oV oR oCOS <br />504 CFR 112.6(b)(4)(i) Failure of owner to assure that a PE makes all required attestations in a Tier II Plan oV oR oCOS <br />General Requirements for SPCC Plans <br />601 CFR 112.7 Failure of Plan to fulfill basic requirements including a cross-referencing section oV oR oCOS <br />602 CFR 112.7(a)(2) Failed to state reasons and detail nonconformance if claiming equivalent environmental protection DV oR DCOS <br />603 CFR 112.7(a)(3) Plan failed to adequately and accurately describe the physical layout of the facility oV oR oCOS <br />604 CFR 112.7(a)(3)(i) Plan failed to include oil type and storage capacity for each container DV DR oCOS <br />605 CFR 112.7(a)(3), <br />25270.4.5(a) <br />Plan failed to include an adequate facility diagram, or no facility diagram was included DV oR o COS <br />606 CFR 112.7(a)(3)(ii) Plan failed to adequately discuss discharge prevention measures, including routine handling of oil oV DR oCOS <br />607 CFR 112.7(a)(3)(iii) Plan failed to adequately discuss facility drainage or drainage controls oV oR oCOS <br />608 CFR 112.7(a)(3)(iv) Plan failed to include countermeasures for discharge discovery, response and cleanup oV oR oCOS <br />609 CFR 112.7(a)(3)(v) Plan failed to address disposal methods for recovered materials EV oR oCOS <br />610 CFR 112.7(a)(3vi), <br />112.7(a4) <br />Plan failed to adequately detail information and procedures for reporting a discharge oV oR oCOS <br />611 CFR 112.7(a)(5) Discharge procedures are not adequately addressed if the facility has no response plan oV DR oCOS <br />612 CFR 112.7(b) Plan doesn't have discharge prediction, including direction, rate of flow, and quantity of oil cV oR oCOS <br />613 CFR 112.7(c) Plan failed to discuss general secondary containment, equipment, or structures to prevent discharge oV DR oCOS <br />614 CFR 112.7(c) Failure to provide appropriate secondary containment, diversionary structures or equipment DV DR oCOS <br />615 CFR 112.7(d) PE certified Plan failed to explain impracticability of containment/diversionary structures oV oR oCOS <br />616 CFR 112.7(d), <br />25270.4.5(a) <br />Failure to perform integrity and leak testing when claiming secondary containment impracticability oV oR oCOS <br />617 CFR 112.7(d)(1) Failed to prepare oil spill contingency plan when claiming containment structure impracticability oV oR oCOS <br />618 CFR 112.7(d)(2) No written commitment of manpower, equipment, and materials to control and remove oil discharge DV DR o COS <br />619 CFR 112.7(e), 112.8(c) <br />(6) <br />Failure to keep written records of procedures, inspections, and tests for at least three years V ER o COS <br />620 CFR 112.7(f)(1) Failed to train personnel on all discharge prevention details listed in this section V DR oCOS <br />621 CFR 112.7(f)(2) Failed to designate a person accountable for discharge prevention oV oR oCOS <br />FA0000110 PR0516364 SC001 05/23/2022 <br />EHD 28-01 Rev. 12/06/2021 <br />Page 2 of 10 <br /> Aboveground Petroleum Storage Act OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 I T 209 468-3420 I F 209 464-0138 I www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.