Laserfiche WebLink
SAN JOAQUIN <br /> Environmental Health Department <br />COUNIY <br /> AMENDED <br />6/22/2022 <br />Aboveground Petroleum Storage Act Inspection Report <br />Facility Name: <br />J & L MARKET <br />Facility Address: <br />8115 S EL DORADO ST, FRENCH CAMP <br />Date: <br />May 23, 2022 <br />General Requirements for SPCC Plans <br />622 CFR 112.7(f)(1), <br />112.7(f)(3) <br />Plan failed to include an adequate description of employee training and annual briefings oV oR DCOS <br />623 CFR 112.7(0(3) Failure to conduct complete annual discharge prevention briefings for oil-handling personnel oV DR oCOS <br />624 CFR 112.7(g) Plan failed to address security of site and valves, lock out/tag out, and lighting oV oR COS <br />625 CFR 112.7(g) Facility failed to implement security measures listed in the SPCC Plan (lighting, security, etc.) oV oR oCOS <br />626 CFR 112.7(h) Plan failed to adequately discuss facility tank car and tank truck loading/unloading rack DV DR oCOS <br />627 CFR 112.7(h)(1) Loading/unloading rack containment system not adequate to contain spill oV oR oCOS <br />628 CFR 112.7(h)(2) Failed to provide vehicular departure warning system for loading and unloading racks DV oR oCOS <br />629 CFR 112.7(a)(1), <br />112.7(j) <br />Failure to include in the Plan discussion of conformance with Federal and State requirements oV oR COS <br />630 CFR 112.7(i), <br />25270.4.5(a) <br />Failed to evaluate field constructed container for brittle fracture and take appropriate action DV DR DCOS <br />631 CFR 112.7(k) Failure to provide general secondary containment or alternative for oil-filled operational equipment DV oR DCOS <br />632 CFR 112.7(i), <br />25270.4.5(a) <br />Failed to document evaluation of discharge for field-constructed tanks due to brittle fracture DV oR oCOS <br />633 CFR 112.8(c)(1)&(2) Plan failed to adequately discuss bulk storage containers including compatibility and containment DV oR COS <br />SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br />701 CFR 112.8(b)(1) Failed to inspect accumulations prior to discharge and ensure controlled drainage from diked areas oV oR oCOS <br />702 CFR 112.8(b)(2) Failed to use manual open-and-closed design valves for the drainage of diked areas oV oR oCOS <br />703 CFR 112.8(b)(3), <br />112.8(b)(4) <br />Failed to design facility drainage system from undiked areas to retain in the facility oV oR oCOS <br />704 CFR 112.8(b)(5) Failed to provide two lift pumps for more than one continuous treatment unit for drainage water V oR DCOS <br />705 CFR 112.8(c)(1) Container not compatible with oil stored and/or storage conditions V oR oCOS <br />706 CFR 112.8(c)(2) Failed to provide and maintain adequate secondary containment for bulk storage tanks V oR oCOS <br />707 CFR 112.8(c)(3) Failure to follow the criteria of this section while allowing drainage of uncontaminated rainwater DV oR oCOS <br />708 CFR 112.8(c)(2), <br />25270.4.5(a) <br />Containment systems for bulk storage tanks are not sufficiently impervious to contain oil on site DV oR COS <br />709 CFR 112.8(c)(3)(iv) Failed to maintain records of drainage from diked areas oV oR oCOS <br />710 CFR 112.8(c)(5) Failed to provide corrosion protection for partially buried tanks oV oR oCOS <br />711 CFR 112.8(c)(6) Plan failed to adequately discuss procedures to test or inspect each container for integrity oV oR COS <br />712 CFR 112.7(e), 112.8(c) <br />(6) <br />Failed to perform scheduled tank tests or inspections by appropriately qualified personnel oV oR oCOS <br />713 CFR 112.7(e), 112.8(c) <br />(6) <br />Failed to test or inspect each container for integrity based on industry standards V oR oCOS <br />714 CFR 112.8(c)(7) Failed to provide effective leakage control from defective internal heating coils DV oR oCOS <br />715 CFR 112.8(c)(8), <br />25270.4.5(a) <br />Failed to have a high level monitoring and to engineer or update containers to avoid discharge oV oR D COS <br />716 CFR 112.8(c)(8)(v) Failed to regularly test liquid level sensing devices to ensure proper operation oV oR oCOS <br />717 CFR 112.8(c)(9) Failed to observe effluent treatment frequently enough to detect potential discharge oV oR COS <br />718 CFR 112.8(c)(10) Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas oV oR COS <br />FA0000110 PRO516364 SC001 05/23/2022 <br />EHD 28-01 Rev. 12/06/2021 <br />Page 3 of 10 Aboveground Petroleum Storage Act OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 I T 209 468-3420 I F 209 464-0138 I www.sjgov.org/EHD