Food Program Service Request Inspection Report
<br />Facility Name and Address: BINGE VIETNAMESE CUISINE, 5779 PACIFIC AVE , STOCKTON 95207
<br />Environmental Health Department
<br /> #35 Equipment/Utensils Approved and in Good Repair
<br />OBSERVATIONS: At the front counter bare wood was observed below the hand sink and absorbent areas were observed
<br />on the cabinet at the end. Repair/paint cabinet and bare wood so that it is smooth, cleanable and non-absorbent. Correct
<br />prior to operation.
<br />CALCODE DESCRIPTION: All utensils and equipment shall be fully operative and in good repair. (114175). All utensils and equipment
<br />shall be approved, installed properly, and meet applicable standards. (114130, 114130.1, 114130.2, 114130.3, 114130.4, 114130.5,
<br />114132, 114133, 114137, 114139, 114153, 114155, 114163, 114165, 114167, 114169, 114172, 114177, 114180, 114182)
<br /> #36 Equipment/Utensils/Linens: Proper Storage / Use
<br />OBSERVATIONS: Observed one CO2 cylinder that was not secured. Store CO2 cylinders upright against a wall and
<br />secured with a chain. Correct today.
<br />CALCODE DESCRIPTION: All clean and soiled linen shall be properly stored non-food items shall be stored and displayed separate from
<br />food and food-contact surfaces. (114185.3 - 114185.4) Utensils and equipment shall be handled and stored so as to be protected from
<br />contamination. (114074 - 114075, 114081, 114119, 114121, 114161, 114178, 114179, 114083, 114185, 114185.2, 114185.5)
<br /> #41 Plumbing Maintained; Approved Back Flow Device
<br />OBSERVATIONS: The ice machine is lacking an air gap. Provide a gap distance of one inch minimum between the end of
<br />the waste pipe and the top of the floor sink. Correct prior to operation.
<br />CALCODE DESCRIPTION: The potable water supply shall be protected with a backflow or back siphonage protection device, as required
<br />by applicable plumbing codes. (114192) All plumbing and plumbing fixtures shall be installed in compliance with local plumbing
<br />ordinances, shall be maintained so as to prevent any contamination, and shall be kept clean, fully operative, and in good repair. Any hose
<br />used for conveying potable water shall be of approved materials, labeled, properly stored, and used for no other purpose. (114171,
<br />114189.1, 114190, 114193, 114193.1, 114199, 114201, 114269)
<br /> #45 Floors, Walls, Ceilings; Clean and Maintained
<br />OBSERVATIONS: A hole was observed in the ceiling panel above the ice machine in the kitchen. Repair/replace ceiling
<br />panel prior to operation.
<br />CALCODE DESCRIPTION: The walls / ceilings shall have durable, smooth, nonabsorbent, light-colored, and washable surfaces. All floor
<br />surfaces, other than the customer service areas, shall be approved, smooth, durable and made of nonabsorbent material that is easily
<br />cleanable. Approved base coving shall be provided in all areas, except customer service areas and where food is stored in original
<br />unopened containers. Food facilities shall be fully enclosed. All food facilities shall be kept clean and in good repair. (114143 (d),
<br />114266, 114268, 114268.1, 114271, 114272)
<br />Page 2 of 4EHD 16-23 Rev. 07/05/2022 Food Program Service Request Inspection Report
<br />FA0018889 SR0084848 SC061 03/01/2023
|