My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SNEDEKER
>
809C
>
2800 - Aboveground Petroleum Storage Program
>
PR0528437
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/7/2023 4:47:04 PM
Creation date
4/3/2023 8:30:55 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0528437
PE
2833
FACILITY_ID
FA0018706
FACILITY_NAME
CANARY RENEWABLES CORP
STREET_NUMBER
809C
STREET_NAME
SNEDEKER
STREET_TYPE
AVE
City
STOCKTON
Zip
95203
APN
16203007
CURRENT_STATUS
01
SITE_LOCATION
809C SNEDEKER AVE
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
490
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />AMENDED <br />3/30/2023 <br />Aboveground Petroleum Storage Act Inspection Report <br />Date: <br />December 08, 2022 <br /> Facility Address: <br /> 809C SNEDEKER AVE, STOCKTON <br /> Facility Name: <br /> CANARY RENEWABLES CORP <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />diked areas. Maintain testing and inspection records. Ensure the correct code is cited for Aboveground Integrity <br />Inspections. Submit a copy of the test/inspection results and correction to the code cited for section 2.5 to the EHD. <br />This is a Class II violation. <br /> 716 CFR 112.8(c)(8)(v) Failed to regularly test liquid level sensing devices to ensure proper operation. <br />OBSERVATION: Per Section 3.3 in the SPCC Plan all tanks have Level Alarm High High Alarms and Level Switch <br />High High floats. Per Compliance Manager - Patrick Samson, liquid level sensing devices for all of the tanks have <br />not been tested. <br />REGULATION GUIDANCE: 112.8(c)(8)(v) You must regularly test liquid level sensing devices to ensure proper <br />operation. <br />CORRECTIVE ACTION: Liquid level sensing devices must be installed in accordance with CFR 112.8 and shall be <br />regularly tested to ensure proper operation. Immediately conduct all necessary testing of all liquid level sensing <br />devices to ensure proper operation. Submit proof of correction to the EHD. <br />This is a Class II violation. <br /> 718 CFR 112.8(c)(10) Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas. <br />OBSERVATION: The facility failed to promptly correct visible discharges of oil from: <br />- The distillation area where T-315 is located. Orange-brown liquid was observed in the containment. The <br />orange-brown liquid led to a drain. <br />- The tank farm area where T-613 is located. Brown liquid was observed in the containment. The liquid lead to a <br />drain. <br />- Biodiesel storage tank farm area. Orange-brown liquid observed throughout containment. The liquid lead to a <br />drain. Per compliance manager, the pipes in this area were replaced 3 weeks ago and liquid could potentially be <br />from that replacement. <br />REGULATION GUIDANCE: 112.8(c)(10) Promptly correct visible discharges which result in a loss of oil from the <br />container, including but not limited to seams, gaskets, piping, pumps, valves, rivets, and bolts. You must promptly <br />remove any accumulations of oil in diked areas. <br />CORRECTIVE ACTION: Immediately remove accumulation in the containment areas, and manage all wastes <br />according to the California Code of Regulations Title 22 hazardous waste regulations, submit proof of correction to <br />the EHD. <br />This is a Class II violation. <br />Overall Inspection Comments: <br />An inspection checklist was provided to the facility operator on the day of inspection (12/8/2022). A complete <br />report was finished on 3/30/2023 and replaces the initial checklist sent on 12/8/2022. Items #205, #601, #604, <br />#613, #614, #629, #706, #713, and #718 were added. <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />FA0018706 PR0528437 SC001 12/08/2022 <br />EHD 28-01 Rev. 12/06/2021 Aboveground Petroleum Storage Act OIRPage 17 of 18 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.