My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CORRESPONDENCE_1994-1999
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
CORRESPONDENCE_1994-1999
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/18/2023 2:28:24 PM
Creation date
4/7/2023 2:11:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
CORRESPONDENCE
FileName_PostFix
1994-1999
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\cfield
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
680
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Y <br /> Facili4- 6., <br /> t Number: <br /> SOLID WASTE Fi PERMIT AeRV JUN 2 o 199439-AA-0015 <br /> 17. LEA Conditions: <br /> A. The combined Forward Landfill and the Forward Resource Recovery Facility permitted tons per operating day shall not exceed <br /> 4,180(peak). <br /> B. Forward Landfill's contaminated soils acceptance program shall comply with the terms and conditions given in the LEA's letters to <br /> Forward dated October 31, 1990; June 5, 1992; and January 7, 1994. <br /> C. This facility shall comply with all terms and conditions of this permit. <br /> D. This facility shall comply with all applicable State minimum standards for solid waste handling and disposal. <br /> E. This facility shall comply with all Federal, State, and Local requirements and enactments,including all mitigation measures given in <br /> any certified environmental document filed pursuant to Public Resources Code, Section 21031.6. <br /> F. Any additional information concerning the design and operation of this facility must be provided upon the request of the local <br /> enforcement agency. <br /> G. This permit is subject to review by the LEA and may be suspended, revoked,or modified at any time for sufficient cause. <br /> H. This facility must conform to the Report of Disposal Site Information dated October of 1993. <br /> I. The LEA reserves the right to suspend or modify waste receiving operations when deemed necessary due to an emergency,an actual <br /> or potential hazard,or creation of a public nuisance. <br /> J. Any change that would cause the design or operation of this facility not to conform to the terms and conditions of this permit is <br /> prohibited. Such a change may be considered a significant change requiring a permit revision. In no case shall the operator implement <br /> any change without first submitting a written notice of the proposed change to the LEA at least 120 days in advance of that change. <br /> K. Safety equipment shall be provided for all employees at the landfill. <br /> L. This facility must comply with the conditions of approval for the land use permit UP-91-12 <br /> M. The operator shall maintain a copy of this permit at the facility to be available at all times to facility personnel and enforcement agency <br /> personnel. <br /> N. A change in operator of this facility shall require a new permit. <br /> O. The Griffolyn TX-1200 (Fire Retardant) synthetic blanket, or equivalent as approved by the LEA, is the only synthetic blanket <br /> approved for use at this facility. <br /> P. Six inches of soil cover material shall be applied at the end of each operating week to the active face where Griffolyn TX-1200 (Fire <br /> Retardant) synthetic blanket was used. <br /> Q. An adequate supply of water or soil shall be kept near the active face to aid in fire suppression. <br /> R. Application and removal of the synthetic blanket shall be done so as to minimize damage(punctures, tears, etc.)to the synthetic <br /> blanket. <br /> S. The operator shall remove from use and discard the synthetic blanket when it no longer functions as an adequate cover material as <br /> outlined in CIW-IvM's "Procedural Guidance For the Evaluation of Alternative Daily Covers". <br /> T. The LEA may order a synthetic blanket removed from service and discarded based on deteriorated condition(s) which prevent it from <br /> functioning as adequate cover. <br /> U. Griffolyn TX-1200 (Fire Retardant) synthetic blanket may only be used to cover non-hazardous solid waste or non-hazardous solid <br /> waste mixed with de-watered sewage or water treatment sludge at a minintum solid-to-liquid ratio of 5:1 by weight. The ultimate <br /> moisture holding capacity of the non-hazardous solid waste shall not be exceeded. <br /> V. Griffolyn TX-1200 (Fire Retardant) synthetic blanket shall not be used to cover designated wastes, asbestos, or any other hazardous <br /> wastes approved by DISC for Class II or III disposal. Six inches of soil cover material shall still be used to cover these wastes daily. <br />
The URL can be used to link to this page
Your browser does not support the video tag.