Environmental Health Department
<br />Facility Name and Address: ESCALON FOOD CENTER, 1602 E MAIN ST, ESCALON 95320
<br />Food Program Official Inspection Report
<br /> #21 Hot and Cold Potable Water Not Available
<br />OBSERVATIONS: 3 comp sink and prep sink in Meat Department have temp at 115F and 119F respectively. Provide 120F
<br />or more today.
<br />Mop sink has no hot water. Provide 120F or more today.
<br />CALCODE DESCRIPTION: An adequate, protected, pressurized, potable supply of hot water and cold water shall be provided at all times.
<br />(113953(c), 114099.2(b) 114101(a), 114189, 114192, 114192.1, 114195)
<br /> #33 Nonfood Contact Surfaces Clean
<br />OBSERVATIONS: Meat department walk in cooler storage shelves are dirty and have build up. Clean shelves today and as
<br />needed.
<br />CALCODE DESCRIPTION: All nonfood contact surfaces of utensils and equipment shall be clean. (114115 (c))
<br /> #34 Warewashing Facilites Maintained
<br />OBSERVATIONS: Prep sink had been removed from back area. Provide prep sink with one drain board in 2 weeks.
<br /> Prep sink must have an indirect connection to drain in floor sink. Pipe, draining the prep sink in the floor sink, must have air
<br />gap at least 1 inch off the floor sink.
<br />CALCODE DESCRIPTION: Food facilities that prepare food shall be equipped with warewashing facilities. Testing equipment and
<br />materials shall be provided to measure the applicable sanitization method. (114067(f,g), 114099, 114099.3, 114099.5, 114101(a),
<br />114101.1, 114101.2, 114103, 114107, 114125)
<br /> #38 Approved / Sufficient Ventilation and Lighting
<br />OBSERVATIONS: Meat department walk in cooler has dim light. Provide adequate light in 1 week.
<br />CALCODE DESCRIPTION: Exhaust hoods shall be provided to remove toxic gases, heat, grease, vapors and smoke and be approved by
<br />the local building department. Canopy-type hoods shall extend 6" beyond all cooking equipment. All areas shall have sufficient ventilation
<br />to facilitate proper food storage. Toilet rooms shall be vented to the outside air by a screened openable window, an air shaft, or a
<br />light-switch activated exhaust fan, consistent with local building codes. (114149, 114149.1) Adequate lighting shall be provided in all areas
<br />to facilitate cleaning and inspection. Light fixtures in areas where open food is stored, served, prepared, and where utensils are washed
<br />shall be of shatterproof construction or protected with light shields. (114149.2, 114149.3, 114252, 114252.1)
<br /> #41 Plumbing Maintained; Approved Back Flow Device
<br />OBSERVATIONS: 3 comp sink is leaking from faucet neck. Fix leakage in 1 week.
<br />CALCODE DESCRIPTION: The potable water supply shall be protected with a backflow or back siphonage protection device, as required
<br />by applicable plumbing codes. (114192) All plumbing and plumbing fixtures shall be installed in compliance with local plumbing
<br />ordinances, shall be maintained so as to prevent any contamination, and shall be kept clean, fully operative, and in good repair. Any hose
<br />used for conveying potable water shall be of approved materials, labeled, properly stored, and used for no other purpose. (114171,
<br />114189.1, 114190, 114193, 114193.1, 114199, 114201, 114269)
<br />Page 2 of 3EHD 16-23 Rev. 09/16/2020 Food Program OIR
<br />FA0018097 PR0526730 SC001 04/07/2023
<br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
|