My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
620
>
1600 - Food Program
>
PR0161809
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/25/2023 9:54:02 AM
Creation date
4/18/2023 3:07:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0161809
PE
1619
FACILITY_ID
FA0000473
FACILITY_NAME
PAQ Inc DBA Rancho San Miguel Market
STREET_NUMBER
620
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
Ln
City
Lodi
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
620 S Cherokee Ln
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN <br /> J O a Q U I N Environmental Health Department <br /> C0U ;N i Y <br /> Food Program Official Inspection Report <br /> Facility Name and Address: PAQ Inc DBA Rancho San Miguel Market, 620 S Cherokee Ln, LODI 95240 <br /> #38 Approved/Sufficient Ventilation and Lighting <br /> OBSERVATIONS:The light shield in the meat department near the 3 comp sink was damaged. Replace light shield within 1 <br /> week. <br /> CALCODE DESCRIPTION:Exhaust hoods shall be provided to remove toxic gases,heat,grease, vapors and smoke and be approved by <br /> the local building department. Canopy-type hoods shall extend 6"beyond all cooking equipment.All areas shall have sufficient ventilation <br /> to facilitate proper food storage. Toilet rooms shall be vented to the outside air by a screened openable window,an air shaft,or a <br /> light-switch activated exhaust fan,consistent with local building codes. (114149, 114149.1)Adequate lighting shall be provided in all areas <br /> to facilitate cleaning and inspection.Light fixtures in areas where open food is stored, served,prepared,and where utensils are washed <br /> shall be of shatterproof construction or protected with light shields. (114149.2, 114149.3, 114252, 114252.1) <br /> #39 Thermometers Provided/Accurate/Easily Visible <br /> OBSERVATIONS:The thermometer display at the 2 D Atosa reach-in w/prep top was not working properly. Provide <br /> accurate thermometer at this unit within 1 week. <br /> CALCODE DESCRIPTION:An accurate easily readable metal probe thermometer suitable for measuring temperature of food shall be <br /> available to the food handler. A thermometer+/-2#F shall be provided for each hot and cold holding unit of potentially hazardous foods <br /> and high temperature warewashing machines. (114157, 114159) <br /> #41 Plumbing Maintained;Approved Back Flow Device <br /> OBSERVATIONS:The floor sinks at the produce 3 comp sink and Tortillaria 3 comp sink were draining slowly. Clean and <br /> provide proper drainage immediately. <br /> Observed debris at floor sink near deli back cooking equipment. Clean today and maintain clean. <br /> CALCODE DESCRIPTION: The potable water supply shall be protected with a backflow or back siphonage protection device,as required <br /> by applicable plumbing codes. (114192)All plumbing and plumbing fixtures shall be installed in compliance with local plumbing <br /> ordinances, shall be maintained so as to prevent any contamination,and shall be kept clean,fully operative,and in good repair. Any hose <br /> used for conveying potable water shall be of approved materials,labeled,properly stored,and used for no other purpose. (114171, <br /> 114189.1, 114190, 114193, 114193.1, 114199, 114201, 114269) <br /> #43 Toilet Facilites Clean/Supplied/Maintained <br /> OBSERVATIONS:The men's employee restroom door is not self-closing. Provide self-closing door within 1 week. <br /> CALCODE DESCRIPTION:Toilet facilities shall be maintained clean, sanitary and in good repair. Toilet rooms shall be separated by a <br /> well-fitting self-closing door. Toilet tissue shall be provided in a permanently installed dispenser at each toilet. The number of toilet <br /> facilities shall be in accordance with local building and plumbing ordinances. Toilet facilities shall be provided for patrons:in <br /> establishments with more than 20,000 sq ft. establishments offering on-site liquor consumption. (114250, 114250.1, 114276) <br /> FA0000473 PRO161809 SCO01 04/12/2023 <br /> EHD 16-23 Rev.09/16/2020 Page 3 of 5 Food Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.