COMPLIANCE INFO_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CRESTWOOD
>
2056
>
2300 - Underground Storage Tank Program
>
PR0542283
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2024 1:10:47 PM
Creation date
5/9/2023 1:04:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0542283
PE
2351
FACILITY_ID
FA0024277
FACILITY_NAME
ARCO AMPM
STREET_NUMBER
2056
STREET_NAME
CRESTWOOD
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
2056 CRESTWOOD AVE
QC Status
Approved
Scanner
SJGOV\lsauers1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7/13/22,11:28 AM UST Program:Monitoring Plan for UST Tank...:CERS Business <br /> Under Dispenser Containment(UDC)Monitoring <br /> .............. ........... ... ._........ <br /> UDC Monitoring Detection of Leak into UDC Triggers Audible and Visual Alarms <br /> Continuous Yes <br /> UDC Leak Alarm Triggers Automatic Pump Shutdown <br /> UDC Panel Manufacturer Yes <br /> VEEDER-ROOT Failure/Disconnection of UDC Monitoring System Triggers Automatic Pump Shutdown <br /> UDC Panel Model# Yes <br /> TLS-350 PLUS UDC Monitoring Stops Flow of Product at Dispenser <br /> UDC Leak Sensor Manufacturer No <br /> VEEDER-ROOT UDC Construction <br /> UDC Leak Sensor Model Double-walled <br /> 794380208 UDC Secondary Containment Monitoring <br /> Vacuum <br /> Leak Within Secondary Containment of UDC Causes Audible and Visual Alarms <br /> Yes <br /> Periodic System Testing <br /> No ELD Testing+i <br /> No Secondary Containment Testing is <br /> Yes Spill Bucket Testing 3Ft <br /> Recordkeepin <br /> Yes Alarm Logs':? <br /> Yes Visual Inspection Records* <br /> No Tank Integrity Testing Results, <br /> No SIR Testing Results 0 <br /> No Tank Gauging Results <br /> No ATG Testing Results <br /> No Corrosion Protection Logs*+ <br /> Yes Equipment Maintenance and Calibration Records <br /> Training <br /> Yes Personnel with UST Monitoring Responsibilities are Familiar with Training Documents' <br /> Specify Other Training Documents <br /> Yes Designated Operator Training <br /> —Comments/Additional Information <br /> Comments and Additional Information <br /> Personnel Responsibilities <br /> Name of First Person Having Responsibility Name of Second Person Having Responsibility <br /> SARVAT SINGH santosh kaur <br /> Title of First Person Having Responsibility Title of Second Person Having Responsibility <br /> owner <br /> co owner <br /> Ykrt 17erak <br /> ;e•r,ian;,.07.0002.1 Enhary<ernan?u;I GFRS Cur:t,aj C��:: iicz; C:n icion;;of U x l Priv-acy Poiicv i Contac?I H(.,4 <br /> California Environmental Reporting System:Business 1 2022 California Environmental Protection Agency <br /> CERS Technical Support:$%guest Te.hni al A ai t nce <br /> Unified Program.'General Assistance:Contact your local regulator(5,) <br /> ....................._,..,_.--------- <br /> _.........- --------------- <br /> . <br /> i '7 <br /> 44'CERS Help Settings <br /> https://cersbusiness2.calepa.ca.gov/204020/Faci lity/1 0842625/Submittal/UST/564202 1/Mon itoringPlan/Detail/25664890 2/2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.