Environmental Health Department <br />Facility Name and Address: YOLANDAS BAKERY, 2860 N CALIFORNIA ST, STOCKTON 95204 <br />Food Program Official Inspection Report <br /> #38 Approved / Sufficient Ventilation and Lighting <br />OBSERVATIONS: Observed gas stove top partially outside exhaust hood. All cooking equipment must be located at least 6 <br />in. inside exhaust hood canopy. Relocate/remove unit today. <br />The light switch for the walk-in freezer light was not working and the light was too dim. Repair light switch and provide <br />adequate lighting for walk-in freezer. Correct within 1 week. <br />Observed missing light shields in exhaust hood and bakery. Provide light shields within 1 week. <br />CALCODE DESCRIPTION: Exhaust hoods shall be provided to remove toxic gases, heat, grease, vapors and smoke and be approved by <br />the local building department. Canopy-type hoods shall extend 6" beyond all cooking equipment. All areas shall have sufficient ventilation <br />to facilitate proper food storage. Toilet rooms shall be vented to the outside air by a screened openable window, an air shaft, or a <br />light-switch activated exhaust fan, consistent with local building codes. (114149, 114149.1) Adequate lighting shall be provided in all areas <br />to facilitate cleaning and inspection. Light fixtures in areas where open food is stored, served, prepared, and where utensils are washed <br />shall be of shatterproof construction or protected with light shields. (114149.2, 114149.3, 114252, 114252.1) <br /> #39 Thermometers Provided/Accurate/Easily Visible <br />OBSERVATIONS: The digital thermometer on the 3 D Atosa reach-in /prep top was not accurate, thermometer read 40 F <br />but the unit was 49 F. Provide accurate thermometer for unit within 1 week. <br />CALCODE DESCRIPTION: An accurate easily readable metal probe thermometer suitable for measuring temperature of food shall be <br />available to the food handler. A thermometer +/- 2 #F shall be provided for each hot and cold holding unit of potentially hazardous foods <br />and high temperature warewashing machines. (114157, 114159) <br /> #40 Proper Use and Storage of Wiping Cloths <br />OBSERVATIONS: Observed used wiping cloth stored on prep table after use. Sanitize wiping cloths with at least 100 ppm <br />chlorine between uses. Correct immediately. <br />CALCODE DESCRIPTION: Wiping cloths used to wipe service counters, scales or other surfaces that may come into contact with food <br />shall be used only once unless kept in clean water with sanitizer. (114135, 114185.1 114185.3 (d-e)) <br /> #41 Plumbing Maintained; Approved Back Flow Device <br />OBSERVATIONS: The front walk-in was installed near front counter in customer area, currently the fan condensate line <br />ends inside the walk-in cooler and there is a bucket under the pipe to catch the discharge. Per operator they working with <br />the City to install a pump for walk-in to pump discharge into floor sink at front counter. Provide approved plumbing indirect <br />connection for walk-in cooler condensate line. Correct within 1 week. <br />CALCODE DESCRIPTION: The potable water supply shall be protected with a backflow or back siphonage protection device, as required <br />by applicable plumbing codes. (114192) All plumbing and plumbing fixtures shall be installed in compliance with local plumbing <br />ordinances, shall be maintained so as to prevent any contamination, and shall be kept clean, fully operative, and in good repair. Any hose <br />used for conveying potable water shall be of approved materials, labeled, properly stored, and used for no other purpose. (114171, <br />114189.1, 114190, 114193, 114193.1, 114199, 114201, 114269) <br />Page 3 of 5EHD 16-23 Rev. 09/16/2020 Food Program OIR <br />FA0015925 PR0523594 SC333 07/24/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD