<br />Facility Name and Address: CASA FLORES, 1032 E HAMMER LN, STOCKTON 95210
<br />Food Program Official Inspection Report
<br /> #35 Equipment/Utensils Approved and in Good Repair
<br />OBSERVATIONS: Observed 2 unsecured 20 lb CO2 cylinders. Keep pressurized cylinders secured to a rigid structure at all
<br />times. Corrected on site.
<br />Observed debris on exhaust hood filters. Clean within 1 week and maintain clean.
<br />Water does not shut off at 3 comp sink faucet head. Repair within 1 week.
<br />Observed ice build up on top and sides of Beverage Air chest in walk-in. Clean within 1 week and repair as necessary.
<br />CALCODE DESCRIPTION: All utensils and equipment shall be fully operative and in good repair. (114175). All utensils and equipment
<br />shall be approved, installed properly, and meet applicable standards. (114130, 114130.1, 114130.2, 114130.3, 114130.4, 114130.5,
<br />114132, 114133, 114137, 114139, 114153, 114155, 114163, 114165, 114167, 114169, 114172, 114177, 114180, 114182)
<br /> #36 Equipment/Utensils/Linens: Proper Storage / Use
<br />OBSERVATIONS: Observed ice scoop stored on counter next to soda machine. Store ice scoop in a cleanable container
<br />when not in use to prevent contamination. Corrected on site.
<br />CALCODE DESCRIPTION: All clean and soiled linen shall be properly stored non-food items shall be stored and displayed separate from
<br />food and food-contact surfaces. (114185.3 - 114185.4) Utensils and equipment shall be handled and stored so as to be protected from
<br />contamination. (114074 - 114075, 114081, 114119, 114121, 114161, 114178, 114179, 114083, 114185, 114185.2, 114185.5)
<br /> #38 Approved / Sufficient Ventilation and Lighting
<br />OBSERVATIONS: The edge of the fryer was slightly outside the exhaust hood canopy. All cooking equipment must be at
<br />least 6 in. inside the exhaust hood canopy. Correct within 1 week and email evidence of correction to dafonskaia@sjgov.org
<br />Lacking light shield at back walk-in light and light bulb above soda/coffee at front counter. Provide light shields or shatter
<br />proof light bulbs for lights above open food areas. Correct within 1 week.
<br />CALCODE DESCRIPTION: Exhaust hoods shall be provided to remove toxic gases, heat, grease, vapors and smoke and be approved by
<br />the local building department. Canopy-type hoods shall extend 6" beyond all cooking equipment. All areas shall have sufficient ventilation
<br />to facilitate proper food storage. Toilet rooms shall be vented to the outside air by a screened openable window, an air shaft, or a
<br />light-switch activated exhaust fan, consistent with local building codes. (114149, 114149.1) Adequate lighting shall be provided in all areas
<br />to facilitate cleaning and inspection. Light fixtures in areas where open food is stored, served, prepared, and where utensils are washed
<br />shall be of shatterproof construction or protected with light shields. (114149.2, 114149.3, 114252, 114252.1)
<br /> #40 Proper Use and Storage of Wiping Cloths
<br />OBSERVATIONS: The sanitizer bucket at the front counter did not have any sanitizer in it. Provide 100 ppm chlorine
<br />minimum in sanitizer bucket. Corrected on site.
<br />CALCODE DESCRIPTION: Wiping cloths used to wipe service counters, scales or other surfaces that may come into contact with food
<br />shall be used only once unless kept in clean water with sanitizer. (114135, 114185.1 114185.3 (d-e))
<br />Page 2 of 4EHD 16-23 Rev. 09/16/2020 Food Program OIR
<br />FA0001063 PR0163131 SC001 05/10/2023