Laserfiche WebLink
Program Element: 3602 - POOL/SPA REPAIR/REMODEL PLAN CHK <br />Telephone: (916) 955-9474 Requestor: TRISTAN TRAYNOR, POOL TIME <br />Inspection Type: 523 - Plan Check/Report Review <br />Address: 8600 N WEST LN , STOCKTON 95210 <br />Date: 11/29/2021Name of Facility: FRIENDLY VILLAGE MHP <br />Swimming Pool Service Request Inspection Report <br /> 4:45 pm <br /> 4:00 pm <br />Time Out: <br />Time In: <br />Request #: SR0084525 <br />Environmental Health Department <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br />OVERALL INSPECTION NOTES AND COMMENTS <br />NOTES <br />Pool remodel for office pool and pool in back <br />In addition to the scope of work provided, the following must be completed during remodel. <br />read: Step must be 21" to 24". the rest of the steps must be 12" to 16" <br />Risers: must beh 6" to 12" <br />Must install trim tile on steps. <br />The handrail must be 28" to 36" from the deck and bottoom step to the top of the handrail. <br />coping : The overhang for either bull-nosed coping or cantilevered decking shall not exceed 2 inches (51 mm) or be less than 1 <br />inch (25 mm) and shall not exceed 2 ½ inches (64 mm) in thickness. <br />Main drain be split 3 feet from inside of cover to cover. <br />3111B.4 Ladder and Recessed Step Dimensions. Ladder treads and recessed steps shall have a minimum tread of 5 inches <br />(127 mm) and a width of 14 inches (356 mm) <br />and shall be designed to be readily cleaned. Step risers shall be uniform and shall not exceed 12 inches (305 mm) in height. <br />The first riser shall be measured from the deck. <br />Plaster must be white. Ok to plaster. <br />The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br />Safety Code. If a reinspection is required, fees will be assessed at the current hourly rate. <br />Received by: Name and Title: <br />EH Specialist:Phone: <br />, <br />VIDAL PEDRAZA <br />Page 1 of 1EHD 36-01 Rev. 06/30/15 Swimming Pool Service Request Inspection Report <br />FA0002581 SR0084525 SC523 11/29/2021