Laserfiche WebLink
Environmental Health Department <br />Time In: <br />12:20 pm <br />11:50 am <br />Time Out: <br />Program Element: 1617 - RETAIL MARKET > 1000 SQ FT W / FOOD PREP <br />Telephone: (650) 588-3088 Owner/Operator: SABERI, TOM <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 1002 FRONTAGE RD, RIPON 95366 <br />Date: 06/22/2023Name of Facility: GAS & SHOP <br />Food Program Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code commencing with section 7; <br />113700. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and have the potential to cause foodborne illness. All major violations must be corrected immediately. Non-compliance may warrant immediate closure of <br />the food facility. <br /> #7 Hot and Cold Holding Temperatures <br />OBSERVATIONS: Hot food items, held on the hot hold at the cooking area, have temp varying between 125F - 131F ( still <br />within the 4 hours time control). Reheat the food items to 165F for at least 15 sec and hold food on the hot hold at 135F or <br />above today. Corrected on site. <br />CALCODE DESCRIPTION: Potentially hazardous foods shall be held at or below 41/ 45°F or at or above 135°F. (113996, 113998, <br />114037, 114343(a)) <br /> #8 Use of Time as a Public Health Control <br />OBSERVATIONS: Cooked food items, on the front counter hot hold, are under 4 hours time control. Temp of the food items <br />are 135F and above. Time log is not maintained. Maintain time log today and regularly after. Corrected on site. <br />CALCODE DESCRIPTION: When time only, rather than time and temperature is used as a public health control, records and <br />documentation must be maintained (114000) <br /> #38 Approved / Sufficient Ventilation and Lighting <br />OBSERVATIONS: Walk in cooler has one burned light bulb. Replace bulb in 1 week. <br />CALCODE DESCRIPTION: Exhaust hoods shall be provided to remove toxic gases, heat, grease, vapors and smoke and be approved by <br />the local building department. Canopy-type hoods shall extend 6" beyond all cooking equipment. All areas shall have sufficient ventilation <br />to facilitate proper food storage. Toilet rooms shall be vented to the outside air by a screened openable window, an air shaft, or a <br />light-switch activated exhaust fan, consistent with local building codes. (114149, 114149.1) Adequate lighting shall be provided in all areas <br />to facilitate cleaning and inspection. Light fixtures in areas where open food is stored, served, prepared, and where utensils are washed <br />shall be of shatterproof construction or protected with light shields. (114149.2, 114149.3, 114252, 114252.1) <br /> #41 Plumbing Maintained; Approved Back Flow Device <br />OBSERVATIONS: Pipe draining the ice maker in the adjacent floor sink, is lacking air gap. Provide air gap at least 1 inch off <br />the floor sink. Correct today. Corrected on site. <br />CALCODE DESCRIPTION: The potable water supply shall be protected with a backflow or back siphonage protection device, as required <br />by applicable plumbing codes. (114192) All plumbing and plumbing fixtures shall be installed in compliance with local plumbing <br />ordinances, shall be maintained so as to prevent any contamination, and shall be kept clean, fully operative, and in good repair. Any hose <br />used for conveying potable water shall be of approved materials, labeled, properly stored, and used for no other purpose. (114171, <br />114189.1, 114190, 114193, 114193.1, 114199, 114201, 114269) <br />Page 1 of 2EHD 16-23 Rev. 09/16/2020 Food Program OIR <br />FA0000650 PR0161567 SC001 06/22/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD