Laserfiche WebLink
SAN-JOAQUIN Environmental Health Department <br /> COUNTY <br /> —"` •- Time In: 9.50 am <br /> Greotness grows here. <br /> Time Out: 10:24 am <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: FLAG CITY RV RESORT Date: 07/17/2023 <br /> Address: 6120 W BANNER ST, LODI 95242 <br /> Owner/Operator: GILL, JASBIR FAMILY LMTD PRTSP Telephone: (209)339-8300 <br /> Program Element: 3611 -PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #24 VGB Suction Covers MAJOR <br /> OBSERVATIONS:Observed damaged right main drain cover. Replace cover. Contact EHD prior to doing work. Keep pool <br /> closed until correction is verified by EHD. <br /> CALCODE DESCRIPTION:All suction outlets shall be equipped with suction covers that meet the applicable ANSIIAPSP-16 performance <br /> standards. (CBC 31378) <br /> #7 Pool Deck <br /> OBSERVATIONS:The coping near the shallow end skimmer had a sharp edge. Provide smooth surface free of cut and trip <br /> hazards. Correct within 1 week. <br /> CALCODE DESCRIPTION:An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br /> top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br /> diving board,ADA device, or slide. (CBC 31148)Pool operator shall keep the pool deck well maintained. (CCR 65535) <br /> #8 Pool and Deck Lighting <br /> OBSERVATIONS:The pool light at the shallow end was not working. Provide working light within 1 week. <br /> CALCODE DESCRIPTION:Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br /> pool. When a pool is used at night,pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br /> not operational, the pool operator shall post a sign in 4-inch letters stating"NO USE OF POOL ALLOWED AFTER DARK"and shall <br /> secure the pool area and not permit any use of the pool after dark. (31158) <br /> #9 Ladders and Handrails <br /> OBSERVATIONS:The ladder rails and hand rails were loose. Secure today. <br /> CALCODE DESCRIPTION:A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br /> handrails shall be corrosion resistant and shall be rigidly installed.At least one handrail shall extend from the deck to not less than a point <br /> above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 311 1B)Pool <br /> operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> FA0016673 PR0524854 SCO01 07/17/2023 <br /> EHD 36-01 Rev.09/16/2020 Page 1 of 3 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />