Laserfiche WebLink
S A N J O a Q U I N Environmental Health Department <br /> — C 0 j :V y <br /> Swimming Pool Official Inspection Report <br /> Facility Name and Address: FLAG CITY RV RESORT, 6120 W BANNER ST, LODI 95242 <br /> #13 Cyanuric Acid Concentration <br /> OBSERVATIONS:The cyanuric acid was greater than 100 ppm. Maintain cyanuric acid between 0-100 ppm. <br /> CALCODE DESCRIPTION:Pool operator shall maintain cyanuric acid concentration between 0.0 ppm and 100 ppm. (CCR 65530) <br /> #15 Operation Records <br /> OBSERVATIONS:Pool testing logs were not maintained. Maintain testing logs for daily chlorine and pH and monthly <br /> cyanuric acid testing. <br /> CALCODE DESCRIPTION:Pool operator shall test the disinfectant residual,pH, and spa water temperature a minimum of once per day. <br /> Cyanuric acid concentration shall be tested once per month if cyanuric acid is used. Combined chlorine shall be tested as often as <br /> necessary to maintain the concentration below 0.4 ppm. Pool operator shall maintain written records of all maintenance and test results <br /> for at least two years and shall submit those records to the enforcement agency upon request. (CCR 65523) <br /> #18 Pool Shell and Tile <br /> OBSERVATIONS:Observed chipping on pool shell at shallow end. Provide smooth pool shell. <br /> CALCODE DESCRIPTION:Pool shells shall be white and have a smooth waterproof interior finish that will withstand repeated brushing, <br /> and scrubbing.A spa pool may be finished in a light color other than white when approved by the enforcement agency. (CBC 31088) <br /> #22 Skimmer Assembly <br /> OBSERVATIONS:Observed chlorine tablets in shallow end skimmer basket. Discontinue this practice and use chlorine <br /> feeder, remove tablets today. <br /> The shallow end skimmer did not have an o-ring. Provide o-ring today. <br /> CALCODE DESCRIPTION:Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br /> maintained in accordance with manufacturer specifications. (CBC 31368) <br /> #36 Pressure and Vacuum Gauges <br /> OBSERVATIONS:The pressure difference between the influent and effluent pressure gauges was greater than 10 PSI. <br /> Recommend clean ing/backwash ing filter. <br /> CALCODE DESCRIPTION:Pressure and vacuum gauges shall be provided for each pump system. (CBC 31258) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: 110 gpm Chlorine: 8.8 ppm Temp: ° F <br /> Cyanuric acid: >100 ppm pH: 7.4 Combined chlorine: ppm <br /> NOTES <br /> FA0016673 PR0524854 SCO01 07/17/2023 <br /> EHD 36-01 Rev.09/16/2020 Page 2 of 3 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />