Laserfiche WebLink
Environmental Health Department <br />Time In: <br />12:09 pm <br />11:14 am <br />Time Out: <br />Program Element: 1626 - RESTAURANT/BAR 101 + SEATS <br />Telephone: (209) 938-1238 Owner/Operator: CRAIG SCHRADER <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 1236 W YOSEMITE AVE, MANTECA 95336 <br />Date: 08/01/2023Name of Facility: McDONALDS #23653 <br />Food Program Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code commencing with section 7; <br />113700. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and have the potential to cause foodborne illness. All major violations must be corrected immediately. Non-compliance may warrant immediate closure of <br />the food facility. <br /> #21 Hot and Cold Potable Water Not Available <br />OBSERVATIONS: Non adjustable back hand sink is at 112F. Provide 100F - 108F today. <br />CALCODE DESCRIPTION: An adequate, protected, pressurized, potable supply of hot water and cold water shall be provided at all times. <br />(113953(c), 114099.2(b) 114101(a), 114189, 114192, 114192.1, 114195) <br /> #33 Nonfood Contact Surfaces Clean <br />OBSERVATIONS: Sides surfaces of the fries fryers and the fries hot hold unit have grease accumulation. Hood filter plates <br />of the fries fryers station have grease accumulation. Clean surfaces today and as needed. <br />Walk in cooler fans covers have build up. Clean covers today and as needed. <br />CALCODE DESCRIPTION: All nonfood contact surfaces of utensils and equipment shall be clean. (114115 (c)) <br /> #38 Approved / Sufficient Ventilation and Lighting <br />OBSERVATIONS: Walk in cooler is missing one of 2 light bulbs. Install new bulb to provide adequate light in the walk in <br />cooler. Correct in 1 week. <br />Walk in freezer is missing one light bulb and other bulb is lacking a cover. Install new bulb and provide a bulb cover to the <br />other one. Correct in 1 week. <br />CALCODE DESCRIPTION: Exhaust hoods shall be provided to remove toxic gases, heat, grease, vapors and smoke and be approved by <br />the local building department. Canopy-type hoods shall extend 6" beyond all cooking equipment. All areas shall have sufficient ventilation <br />to facilitate proper food storage. Toilet rooms shall be vented to the outside air by a screened openable window, an air shaft, or a <br />light-switch activated exhaust fan, consistent with local building codes. (114149, 114149.1) Adequate lighting shall be provided in all areas <br />to facilitate cleaning and inspection. Light fixtures in areas where open food is stored, served, prepared, and where utensils are washed <br />shall be of shatterproof construction or protected with light shields. (114149.2, 114149.3, 114252, 114252.1) <br />Page 1 of 3EHD 16-23 Rev. 09/16/2020 Food Program OIR <br />FA0012283 PR0515685 SC001 08/01/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD