Laserfiche WebLink
DRAFT [TENTATIVE] WASTE DISCHARGE REQUIREMENTS ORDER R5-2023-OOXX 67 <br /> FORWARD, INC. <br /> FORWARD LANDFILL <br /> SAN JOAQUIN COUNTY <br /> STANDARD PROVISIONS & REPORTING REQUIREMENTS <br /> 2. Leachate and landfill gas condensate collected from a waste management <br /> unit shall be discharged to the unit from which it came, or discharged to an <br /> appropriate waste management unit in accordance with Title 27 and in a <br /> manner consistent with the waste classification of the liquid [Title 27, <br /> § 20200(d) and § 20340(g)]. <br /> 3. The discharge of leachate or landfill gas condensate is restricted to those <br /> portions of a waste management unit that has a composite liner system <br /> and LCRS meeting the Federal Subtitle D requirements [40 C.F.R. <br /> § 258.28]. <br /> 4. Leachate and condensate returned to a composite-lined landfill unit (when <br /> approved by this Order) shall be discharged and managed such that it <br /> does not cause instability of the waste, does not cause leachate seeps, <br /> does not generate additional landfill gas that is not extracted from the <br /> landfill by an active landfill gas extraction system, does not cause <br /> contaminants to enter surface water runoff, and does not cause leachate <br /> volumes to exceed the maximum capacity of the LCRS. <br /> 5. Any discharge of waste outside the portion of the landfill that was already <br /> covered with waste as of the landfill unit's respective Federal Deadline <br /> constitutes a "lateral expansion" and requires the installation of an <br /> approved composite liner system and LCRS [40 C.F.R. § 258.40(b)]. <br /> 6. Wastes shall be discharged only into waste management units specifically <br /> designed for their containment and/or treatment, as described in this <br /> Order. <br /> 7. The discharge shall remain within the designated disposal area at all <br /> times. <br /> 8. The discharge of waste shall not cause a nuisance condition [Wat. Code, <br /> § 13050(m)]. <br /> E. Standard Facility Specifications <br /> 1. All waste management units shall be designed, constructed, and operated <br /> to ensure that wastes, including leachate, will be a minimum of 5 feet <br /> above the highest anticipated elevation of underlying groundwater <br /> [Title 27, § 20240(c)], including the capillary fringe. <br /> 2. Surface and subsurface drainage from outside of a waste management <br /> unit shall be diverted from the unit [Title 27, § 20365(e)]. <br />