Laserfiche WebLink
DRAFT [TENTATIVE] WASTE DISCHARGE REQUIREMENTS ORDER R5-2023-OOXX 73 <br /> FORWARD, INC. <br /> FORWARD LANDFILL <br /> SAN JOAQUIN COUNTY <br /> STANDARD PROVISIONS & REPORTING REQUIREMENTS <br /> 21. Leachate collection and removal systems shall be designed and operated <br /> to function without clogging through the scheduled closure of the landfill <br /> unit and during the post-closure maintenance period. <br /> 22. The LCRS shall be designed to maintain the depth of fluid over any <br /> portion of the LCRS of no greater than 30 cm [40 C.F.R. § 258.40(a)(2)], <br /> excluding the leachate sump. The leachate sump, leachate removal pump, <br /> and pump controls shall be designed and set to maintain a fluid depth no <br /> greater than the minimum needed for efficient pump operation [Title 27, <br /> § 20340(c)]. <br /> 23. All construction of liner systems and final cover systems shall be <br /> performed in accordance with a Construction Quality Assurance Plan <br /> certified by a registered civil engineer or a certified engineering geologist <br /> [Title 27, § 20323]. <br /> 24. The Construction Quality Assurance program shall be supervised by a <br /> registered civil engineer or a certified engineering geologist who shall be <br /> designated the CQA officer [Title 27, § 20324(b)(2)]. <br /> 25. The Discharger shall ensure that a third party independent of both the <br /> Discharger and the construction contractor performs all of the construction <br /> quality assurance monitoring and testing during the construction of a liner <br /> system. <br /> 26. The Discharger shall notify Central Valley Water Board staff at least <br /> 14 days prior to commencing field construction activities including <br /> construction of a new lined cell or module, construction of a final cover, or <br /> any other construction that requires Central Valley Water Board staff <br /> approval under this Order. <br /> 27. The Discharger shall submit for review and approval at least 60 days prior <br /> to proposed discharge, final documentation required in Title 27 Section <br /> 20324(d)(1)(C) following the completion of construction of a new lined <br /> landfill module. The report shall be certified by a registered civil engineer <br /> or a certified engineering geologist and include a statement that the liner <br /> system was constructed in accordance with the approved design plans <br /> and specifications, the CQA Plan, the requirements of the WDRs, and that <br /> it meets the performance goals of Title 27. The report shall contain <br /> sufficient information and test results to verify that construction was in <br /> accordance with the design plans and specifications, the construction <br /> quality assurance plan, and the performance goals of Title 27. <br />