My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2025 12:03:45 PM
Creation date
8/16/2023 2:19:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\cfield
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
474
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DRAFT [TENTATIVE] WASTE DISCHARGE REQUIREMENTS ORDER R5-2023-OOXX 86 <br /> FORWARD, INC. <br /> FORWARD LANDFILL <br /> SAN JOAQUIN COUNTY <br /> STANDARD PROVISIONS & REPORTING REQUIREMENTS <br /> samples such as non-naturally occurring constituents like volatile <br /> organic compounds; and <br /> b. Standard Monitoring Specification 1.47 provides the procedure for <br /> analytes that are detected in 10% or greater of the background <br /> samples such as naturally occurring constituents like chloride. <br /> 46. Verification Procedure for Analytes Detected in Less than 10% of <br /> Background Samples. The Discharger shall use the following non- <br /> statistical method for all analytes that are detected in less than 10% of the <br /> background samples. The non-statistical method shall be implemented as <br /> follows: <br /> a. Initial Determination of Measurably Significant Evidence of a <br /> Release. Identify each analyte in the current detection monitoring <br /> point sample that exceeds either its respective MDL or PQL, and <br /> for which a release has not been previously confirmed. The <br /> Discharger shall conclude that the exceedance provides a <br /> preliminary indication of a release or a change in the nature or <br /> extent of the release, at that monitoring point, if either: <br /> i. The data contains two or more analytes that equal or exceed <br /> their respective MDLs; or <br /> ii. The data contains one or more analyte that equals or <br /> exceeds its PQL. <br /> b. Discrete Retest [Title 27, § 20415(e)(8)(E) and § 204200)(1-3)]: <br /> i. In the event that the Discharger or Central Valley Water <br /> Board staff concludes (pursuant to paragraph 1.46.a., above) <br /> that there is a preliminary indication of a release, then the <br /> Discharger shall immediately notify Central Valley Water <br /> Board staff by phone or e-mail and, within 30 days of such <br /> indication, shall collect two new (retest) samples from the <br /> monitoring point where the release is preliminarily indicated <br /> and analyze them for the constituents that caused the need <br /> for the retest. <br /> ii. Confirmation of a Release. As soon as the retest data are <br /> available, the Discharger shall conclude that measurably <br /> significant evidence of a release is confirmed if (not including <br /> the original sample) two or more analytes equal or exceed <br />
The URL can be used to link to this page
Your browser does not support the video tag.