Laserfiche WebLink
CLIENT: <br /> by <br /> 0 0 0 <br /> 7'CONCRETE SLAB <br /> 6'STEEL BUILDING 3' MIN. <br /> (TYP-) <br /> BOLLARDS(TYP.) <br /> O 8"MINIMUM THICK CONCRETE SLAB <br /> (TYP.) <br /> HORIZONTAL HEALY TANK(TYP.) ARCS <br /> IF WEST COAST PRODUCTS,LLC <br /> r—1—---) __--, <br /> NO. DATE DESCRIPTION <br /> (-- <br /> m <br /> sk <br /> I I o <br /> I � I <br /> SEAL: <br /> GENERAL ENCLOSURE DESIGN REQUIREMENTS NOTES CCGF111yyy�yyy$ <br /> O O O WHEN AN ENCLOSURE IS REQUIRED BY AUTHORITY HAVING JURISDICTION THE <br /> EQUIPMENT MOUNTING SLAB SHALL BE DESIGNED FOR THE SIZE AND THICKNESS N0. 36475 <br /> REWIRED TO ACCOMMODATE BOTH THE FFS/HEALY CLEAN AIR SEPARATOR AND * XP.B-30-2 <br /> HORIZONTAL "HEALY" ENCLOSURE ANCHOR LAYOUT THE ENCLOSURE.ALL NEW FOUNDATIONS AND PADS SHALL BE INSTALLED <br /> LEVEL. 1 V11 <br /> THE ENCLOSURE MUST NEVER BE INSTALLED CLOSER THAN 5-FEET FROM ANY <br /> BUILDING. <br /> IN SIZING THE HORIZONTAL ENCLOSURE,THERE MUST BE A 4-FOOT MINIMUM <br /> CLEARANCE FROM THE FLANGE OF THE HORIZONTAL FFS/HEALY CLEAN AIR <br /> SEPARATOR TANK TO THE DOOR OF THE ENCLOSURE IN ORDER TO HAVE CLEAR z <br /> WORKING SPACE FOR THE INSTALLED PIPING CONNECTIONS.THE SHALL BE A <br /> FRESH AIR VENT 12'MINIMUM <br /> MINIMUM OFF 18-INCHES CLEAR AROUND THE REST OF THE ENCLOSURE FROM w n <br /> < m <br /> ABOVE GRADE(TYP.) THE TANK.SMALLER ENCLOSURE CLEARANCES ARE NOT ENCOURAGED AND z <br /> SHALL REQUIRE PRIOR APPROVAL FROM THE BP PROJECT MANAGER. <br /> IN SIZING THE VERTICAL ENCLOSURE,AN 18-INCH MINIMUM CLEAR DISTANCE z m <br /> SHALL BE MAINTAINED AROUND THE FFS/HEALY TANK. y F <br /> \ mZ om v <br /> THE HEIGHT OF THE ENCLOSURE MUST BE A MINIMUM OF 18'ABOVE THE TOP ¢LT <br /> 0. <br /> OF THE FFS/HEALY CLEAN AIR SEPARATOR TANK. a W z z <br /> '• `� fi h w oOzo <br /> PIPING FROM THE FFS/HEALY CLEAN AIR SEPARATOR TO VENT STACK TIE-IN M a Z <br /> 1� v <br /> TIE INTO VENT RISER.DO NOT POINT MUST NOT PENETRATE THE ENCLOSURE. i Z¢op z N <br /> PENETRATE ENCLOSURE WALL(TYP.) UNIONS SHALL BE INSTALLED IN THE PIPING RUNS NEAR THE FLANGE OF THE a W w z O <br /> rp, FFS/HEALY CLEAN AIR SEPARATOR IN ORDER TO FACILITATE REMOVAL OF THE ¢ro <br /> PIPING FOR MAINTENANCE AND SERVICING OF THE INTERNAL BLADDER. w U <br /> TYPICAL BOLLARD PROTECTION �� \� DISTANCE FROM THE FFS/HEALY CLEAN AIR SEPARATOR TO THE VENT TIE-IN Q 0 p <br /> (TYP-) ,1 LOCATION MUST NOT EXCEED 10 FEET WITHOUT THE APPROVAL OF THE OWNERS i a <br /> REPRESENTATIVE OR PROJECT MANAGER. z <br /> ti <br /> THE ENCLOSURE MUST BE PROTECTED WITH TRAFFIC BOLLARDS MERE NEEDED g <br /> 000 <br /> aAND SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA FIRE CODE DEVELOPMENT INFORMATION: <br /> SECTION 312 <br /> ENCLOSURE SHOP DRAWINGS AND STRUCTURAL CALCULATIONS FOR PERMIT <br /> ` SUBMITTALS SHOULD BE OBTAINED FROM THE SPECIFIC MANUFACTURER BEING <br /> II 1` USED.ADDITIONAL CALCULATIONS MAY BE REWIRED BY LOCAL JURISDICTIONS. <br /> \\` <br /> SITE ADDRESS: <br /> IN WEST MARCH LANE <br /> SrIOCKTON,CA OW <br /> `4r <br /> DESICiED BY: <br /> CHECKm BY: <br /> DRAWN BY: ER <br /> I I BOLTED ��/1 DA1E: PROJECT N0. <br /> GROUND 09)10)2021 7161 <br /> lJ CONNECTION j <br /> I I / TO POSTI DRAWING TITLE: <br /> 1 / ESIGN INTENT:FFS/HEALY CLEAN AIR <br /> SEPARATOR GENERAL ENCLOSURE <br /> #4 BARE �� DESIGN <br /> (CALI(CALIFORNIA ONLY) <br /> STRANDED CU <br /> GROUND WIRE SHEET NO: <br /> TANK FIELD <br /> GROUNDING <br /> J SYSTEM <br /> ISOMETRIC VIEW—HORIZONTAL ENCLOSURE G-0-6.7 <br />