My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
1243
>
2300 - Underground Storage Tank Program
>
PR0548639
>
INSTALL_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/18/2024 10:04:08 AM
Creation date
9/14/2023 10:11:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2023
RECORD_ID
PR0548639
PE
2351
FACILITY_ID
FA0027823
FACILITY_NAME
ARCO AM/PM
STREET_NUMBER
1243
Direction
W
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95215
APN
10816016
CURRENT_STATUS
01
SITE_LOCATION
1243 W MARCH LN
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ O A Q U I N Environmental Health Department <br /> COUNTY <br /> F. SYSTEM PIPING CONTINUED: <br /> Check Code <br /> Box Section <br /> / HSC Piping compatible with material intended to be stored. <br /> Lv7 25290.1 c 1 <br /> 25290.2 c 1 <br /> 23 CCR <br /> / 2631(b) Design and construction of piping approved by independent testing organization (e.g. UL). <br /> l� Piping, including vent lines, sloped toward tank(s)with minimum 1/8 inch slope per 1 foot of run. <br /> 2 250.1 k Vapor recovery, fill riser, and vent line piping are secondarily contained. <br /> 25290.2c3&(j) <br /> G. OVERSPILL/ OVERFILL PREVENTION: <br /> Check Code <br /> Box Section <br /> 23 CCR Overspill containment having minimum capacity of 5 gallons provided at each tank fill location. <br /> 2635(b) <br /> Manufacturer OPW Model PK12-FLMP-RSC-BP/PK12-FLMP-WSC-BP/PK13-FLDIESEL-YOSC-B <br /> Approved overfill prevention device provided at each tank fill location. <br /> Choose One of the following methods: <br /> ❑ Alert the transfer operator when the tank is 90 percent full by restricting the flow into the tank or <br /> triggering an audible visual alarm <br /> ❑ Restrict delivery of flow to the tank at least 30 minutes before the tank overfills, provided the <br /> 23 CCR restriction occurs when the tank is filled to no more than 95 percent capacity; and activate an <br /> 2635(b)(2) audible alarm at least five minutes before the tank overfills <br /> IM/Provide positive shut-off flow to the tank when the tank is filled to no more than 95 percent of <br /> capacity. <br /> ❑ Provide positive shut-off of flow to the tank so that none of the fittings located on the top of the <br /> tank are exposed to product due to overfilling. <br /> Manufacturer OPW Model OPW-71SO-41OC-EVR <br /> H. CORROSION PROTECTION: <br /> Check Code <br /> Box Section <br /> Fiberglass reinforced plastic(FRP) <br /> Piping corrosion protection: ❑ Steel with cathodic protection or impressed current <br /> 23 CCR ❑ Steel isolated from contact with backfill <br /> 2636(b) <br /> FRP or equivalent non-metallic exterior coatings or coverings <br /> Tank corrosion protection: ❑ Sacrificial Anode <br /> 23 R <br /> 2635(a)(2) ❑ Steel tank with field installed cathodic protection or impressed <br /> current <br /> Tie-downs,when used, constructed of non-corrosive material or coated steel. <br /> 7 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.