Laserfiche WebLink
SAN JOAQUIN <br />COUNTY <br />Environmental Health Department <br />gallons of water for warewashing and food preparation must be provided. (CRFC Section <br />114217) <br />A water heater with a minimum capacity of four gallons shall be provided for mobile food facilities <br />that have a warewashing sink. (CFRC Section 114325) <br />Mechanical exhaust ventilation equipment shall be provided over all cooking equipment as <br />required to effectively remove cooking odors, smoke, steam, grease, heat, and vapors. All <br />mechanical exhaust ventilation equipment shall be installed and maintained in accordance with <br />the California Mechanical Code, except that for units subject to Part 2 (commencing with Section <br />18000) of Division 13, an alternative code adopted pursuant to Section 18028 shall govern the <br />construction standards. (CFRC Section 114149.1) <br />Passthrough window service openings shall be limited to 216 square inches each. The service <br />openings shall not be closer together than 18 inches. Each opening shall be provided with a solid <br />or screened window, equipped with a self-closing device. Screening shall be at least 16 mesh <br />per square inch. Pass through windows of up to 432 square inches are approved if equipped with <br />an air curtain device. The counter surface of the service openings shall be smooth and easily <br />cleanable. (CRFC Section 114259.2.) <br />Floors, walls, and ceilings of all enclosed FOOD PREPARATION areas shall be constructed so <br />that the surfaces are impervious, SMOOTH, and EASILY CLEANABLE. Floor surfaces shall <br />provide EMPLOYEE safety from slipping. The juncture of the floor and wall shall be coved with <br />a 3/8 inch minimum radius coving, with the floor surface extending up the wall at least four inches. <br />(CFRC 114301) <br />This facility shall have a sink with at least three compartments with two integral metal drain <br />boards, and must have an indirect connection for waste discharge. The sink compartments and <br />drainage facilities shall be large enough to accommodate immersion of the largest equipment <br />and utensils [CRFC §114099]. <br />The EHD must be kept informed of the construction progress. A final inspection must be performed, <br />operating permit fees paid, and approval to operate granted prior to opening for business. All equipment <br />must be installed and thorough cleaning completed prior to the final inspection. Inspections must be <br />scheduled at least 48 hours in advance. Charges for additional inspections, re-inspections and/or <br />consultations may be assessed at the EHD hourly rate of $156 per hour. <br />Any item(s) inadvertently overlooked in the plan check process, which is not in compliance with <br />applicable State laws, and/or city or county ordinance codes, shall be constructed or reconstructed upon <br />request of the EHD. Inferior workmanship, equipment, or materials will not be accepted for the <br />construction or operation of a food facility. Any variance from the requirements outlined in this letter will <br />require written approval from the EHD. Approval of the submitted plans shall become null and void if <br />the work authorized is not commenced within 180 days from the date of approval, or the work authorized <br />by such plans is abandoned. In order to renew action on an expired plan approval, the applicant shall <br />submit fees equal to that of a new plan review. A copy of the approved plans shall be available on site <br />at the time of final inspection. <br />If you have any questions, please contact Stephanie Ramirez, Senior Registered Environmental <br />Health Specialist, at (209) 616-3069. <br />Sincerely, <br />Jeff Carruesco, REH , RDI <br />2 of 3