Laserfiche WebLink
OPW 42" DIA. MULTI-PORT DUAL POINT AGCOC.Conn <br /> 4" VAPOR RECOVERY ADAPTER & CAP IN SPILL FILL SPILL CONTAINMENT ASSEMBLY W/ (2) <br /> CONTAINMENT FILL BOX. PER CARB EVR VR-102, 5 GALLON SPILL BUCKETS CARB STAGE I <br /> NO DRAIN VALVE TO BE INSTALLED ON VAPOR EVR COMPLIANT PER VR-102, AND <br /> RECOVERY SPILL BUCKET. (TYP.) ADJUSTABLE FLARED SKIRT V <br /> Z <br /> 5 GALLON SPILL CONTAINER. 4" MIN. TO 4" FILL ADAPTER AND CAP IN SPILL <br /> (INLINE DRAIN ON FILL BUCKET ONLY) TOP OF SPILL <br /> BUCKET CONTAINMENT FILL BOX (TYP.) <br /> a <br /> THICKENED CONCRETE 11 WATERTIGHT SUMP SHIELD LLi <br /> SLAB (TYP.) 42 18 BOOT AND CLAMPS V <br /> Z <br /> ( MINI HYDROSTATIC O <br /> SUMP SENSOR U <br /> z (TAPE ° a Z <br /> g DEPTH 9" ° a d v <br /> Cn MIN. 12" ° ° c� ° ° o <br /> MAX. <br /> Lu <br /> j ! PEA GRAVEL BACKFILL (TYP.) <br /> 6 WIDE DETECTABLE UNDERGROUND � N <br /> CO co cri <br /> MARKING TAPE » 0 3'-5» o 2-IN-1 SENSOR BOX V CO rn 0) <br /> EMPIRE MAGNATEC #32-143 1 v <br /> JUNCTION BOX Q - <br /> 4" GALV. STEEL RISERS STAGE LO <br /> I VAPOR RISER IS IN SAME ! SEE STATIC GROUNDING DETAILS M o <br /> PLANE AS TANK LEVEL GAUGE j ON SHEET G.0.7.2 (TYP.) N z a <br /> IN THIS VIEW I I <br /> CONTRACTOR TO INSTALL CLEVIS ! I #4 STRANDED BARE CU <br /> AND COTTER PIN I I GROUND WIRE TO OTHER <br /> I I TANKS (TYP.) ,- <br /> TANK GAUGE ADAPTER m U <br /> & CAP I F #4 STRANDED BARE CU <br /> GROUND WIRE TO <br /> VEEDER ROOT .1 GPH MAGNOSTRICTIVE i GROUND ROD (TYP.) <br /> PROBE TANK LEVEL PROBE W/ TLS CAP ! 1" FRP BONDED ENTRY FITTING <br /> & RING. OVERFILL ALARM SET © 90% z I I <br /> CAPACITY. USE 2" FLOAT IN INSTALL KIT 5� ! I (TYP.) <br /> I I <br /> 0o I 1" MONITORING CONDUIT (TYP.) <br /> i <br /> (ROBROY THROUGH SUMP ONLY) <br /> T 42" DOUBLE WALL POLYGON SUMP <br /> BODY (8) FLAT PANELS <br /> I I <br /> I I <br /> I ! 22" MANWAY <br /> I N <br /> I I SUMP MONITOR LIQUID SENSOR <br /> O <br /> MOUNTED IN HOLDER <br /> STRAIGHT DROP TUBE Ld <br /> WITH FLAPPER (TYP.) <br /> A: SECTION VIEW - FILL SIDE SUMP (SINGLE FILL W/ MANWAY) <br /> SCALE: 3/4" = 1'-0" <br /> w <br /> SUMP MONITORING LIQUID <br /> MANWAY JACK SCREW (TYP.) SENSOR J <br /> 8" ACCESS PORT <br /> 8» 8" 00 <br /> W <br /> �I �I VEEDER ROOT .1 GPH MAGNOSTRICTIVE <br /> a <br /> cwi�I N_I `�'I PROBE TANK LEVEL PROBE W/ TLS CAP <br /> I I I & RING. OVERFILL ALARM SET © 90% La co <br /> J I I I CAPACITY. USE 2" FLOAT IN INSTALL KIT N <br /> o z <br /> 1 o a <br /> i ® <br /> I I 4" VAPOR RECOVERY ADAPTER & CAP IN SPILL <br /> CONTAINMENT FILL BOX. PER CARB EVR VR-102, <br /> 0 1 ! 1 0 NO DRAIN VALVE TO BE INSTALLED ON VAPOR <br /> 0 I I RECOVERY SPILL BUCKET <br /> I <br /> TA �NK - �---- - - ----�---- - - -0 ------ <br /> I o <br /> 4" FILL ADAPTER AND CAP IN SPILL 0 I I I 0 <br /> CONTAINMENT FILL BOX ! 1 <br /> I I I0 <br /> 0 0 0 ° ' ALL MANHOLE ACCESS COVERS TO BELOW GRADE <br /> I I SHALL BE LIQUID TIGHT AND LOCKABLE <br /> 0 oo Qv voo v v 0 42" DIA. MULTI-PORT SINGLE DUAL POINT <br /> FILL SPILL CONTAINMENT ASSEMBLY W/ (2) <br /> 5 GALLON SPILL BUCKETS CARB STAGE I <br /> EVR COMPLIANT PER VR-102 -�0- <br /> DIAMOND PLATE 42" DIA. BRINE MONITORED DOUBLE WALL <br /> CONTAINMENT SUMP (TYP.) <br /> NOTES <br /> SLOPE CONCRETE AWAY FROM ALL MANHOLES 1" RISE OVER 12" RUN <br /> B: PLAN VIEW - FILL SIDE SUMP (SINGLE FILL W/ MANWAY) <br /> FIBER REINFORCEMENT TO BE USED. PRE-MIX UNIFORMLY THROUGHOUT CONCRETE. OO <br /> SCALE: 3/4" = 1'-0" <br /> REINFORCING BARS TO BE NO LESS THAN 2" AND NO MORE THAN 4" FROM SURFACE. <br /> REINFORCE CONCRETE SLAB AROUND MANHOLE WITH 4-#3 REBAR 60" IN LENGTH. <br /> 33" O.D. (SINGLE FILL) PLACE REBAR 6" FROM SIDES OF BOX. <br /> ONE 1" STANDARD MONITORING HOMERUN CONDUIT TO EACH TANK. FOR STANDARD vJ <br /> MONITORING DEVICES, LOOP CONTAINMENT SUMP SENSORS, PLLD, VAC SENSORS & TANK <br /> GAUGE TO TANK INTERSTITIAL SENSOR LOCATION AND HOMERUN TO BLDG. PROVIDE W <br /> SEAL-OFFS IN BUILDING & PRIOR TO LEAVING HAZARDOUS AREA. ROUTE TO INTRINSICALLY Q <br /> o SAFE TROUGH IN BUILDING. CONDUITS SHALL CONTAIN ONLY LOW VOLTAGE WIRING FOR _ <br /> SENSORS. ALL CONDUIT PENETRATIONS MUST BE MADE WITH ROBROY PVC COATED �^ <br /> o z o CONDUIT ONLY. vJ <br /> SLIP ON RISER 42" I.D. z JWu <br /> w PEA GRAVEL BACKFILL. ALL SUBSTITUTES MUST BE APPROVED BY MANUFACTURER AND J <br /> Cn g �' OWNER'S FIELD REPRESENTATIVE. <br /> FIELD SEALED JOINT. DW POLYGON BODY a <br /> (ADHESIVE SUPPLIED Q PIPING SHALL BE LAID AND CONTINUOUSLY SUPPORTED ON A 6 COMPACTED PEA <br /> W/ KIT) GRAVEL BEDDING. PIPING SHALL NOT BE SUPPORTED BY BLOCKS, PLANKS, OR OTHER LLJ <br /> DEBRIS. Z Cw �W <br /> ALL ENTRIES TO BE PERPENDICULAR TO CONTAINMENT SUMP. OFFLINE INSTALLATION = Z <br /> 3/8 X 1/4 SS <br /> NOT PERMITTED. U = J <br /> BUSHING REAM ALL RISERS FOR FULL PIPE BORE IF REQUIRED. O <br /> INSTALLED AT Z <br /> FACTORY INSTALL TANK ID MARKERS IN THE SPILL CONTAINMENT MANHOLES. COVERS SHALL BE Q <br /> N PRIMED AND PAINTED ACCORDING TO SPECIFICATIONS. z <br /> FACTORY SECONDARY CONTAINMENT IS REQUIRED FOR ALL VENT AND STAGE II VAPOR RECOVERY n <br /> LAY-UP DW COLLAR PIPING. OO 0 `J <br /> BONDED TO <br /> TANK COAT ALL BURIED GALVANIZED STEEL WITH COAL TAR EPDXY. <br /> consultant job# <br /> LAYOUT TANKS & STAGE II VAPOR RECOVERY PIPING SUCH THAT THE STAGE II PIPING <br /> JOINT DETAILS 2 DRAINS & ENTERS INTO REGULAR UNLEADED TANK FIRST W/ 3" CONNECTIONS, AND master release date <br /> CONTINUES 3" TO OTHER TANKS. <br /> OCONTRACTOR TO ADDITIONALLY GLASS WRAP & LAMINATE AT CONNECTION FOLLOWING CURING OF 42" DIA. POLYGON SUMP BODY CONCRETE SHALL BE THICKENED AT THE THE FILL SUMPS DOWN TO BELOW THE TOP project master <br /> ADHESIVE. SPECIFIC ATTENTION MUST BE GIVEN TO SURFACE PREP AS TESTING REQUIREMENTS (8) 17 3/8" FLAT PANELS OF CONTAINMENT OF THE DOUBLE WALL SUMP AS REQUIRED. DIMENSION OF SLAB exe date drawn by <br /> WILL DETECT THE SMALLEST OF FLAWS. ALL MATERIALS MUST BE COMPATIBLE WITH GASOLINE, THICKNESS VARIES WITH SITE CONDITIONS. <br /> GASOLINE WITH 15% MTBE (METHYL TERTIARY-BUTYL ETHER), OR GASOLINE WITH 10% ETOH 1/4" DRAIN/TEST BUSHING. <br /> FACTORY INSTALLED CROSSING FLEX CONNECTORS MUST MAINTAIN A MINIMUM OF 2 INCH CLEARANCE OR <br /> (ETHANOL). FIBERGLASS AND RESIN MUST EXTEND 1/2" BEYOND COVERAGE OF ADHESIVE. THE USE OF AN ANTI CHAFING DEVICE MUST BE INSTALLED. NOTE: CONTRACTOR TO USE ADDITIONAL <br /> NOTE: Facility/Project <br /> OTHE STRAP CHANNEL IF PRESENT ON THE FILL SIDE SUMP DOES NOT "COMMUNICATE" WITH CONTRACTOR SHALL BE HELD RESPONSIBLE GALVANIZED FITTINGS AS REQUIRED TO <br /> THE INSIDE OF THE SUMP. CONTRACTOR TO BE SURE TO LEAVE UNOBSTRUCTED PATH FOR FOR PROPER INSTALLATION & PREPARATION MINIMIZE BENDS IN FLEXIBLE CONNECTORS <br /> STRAP TO PENETRATE INTO THE CHANNEL SO THAT TANKS MAY BE PROPERLY ANCHORED. PER MANUFACTURERS INSTRUCTIONS AND <br /> SHALL REINSTALL SUMPS IF HYDROSTATIC <br /> C: TYPICAL DOUBLE WALL FILL SUMP TESTING SHOWS LEAKING IN THIS AREA OF sheet name <br /> THE SUMP. M .5.3 . 16 <br /> SCALE: 3/4" = 1'-0" 'v' <br />