OPW 42" DIA. SINGLE-PORT FILL SPILL <br /> AGCDC.COM <br /> CONTAINMENT ASSEMBLY W/ (1) 5 GALLON SPILL <br /> BUCKET AND ADJUSTABLE FLARED SKIRT <br /> 4 FILL ADAPTER AND CAP IN SPILL 4" MIN. TO Z ` <br /> CONTAINMENT FILL BOX (TYP.) TOP OF SPILL 5 GALLON SPILL CONTAINER. <br /> WATERTIGHT SUMP SHIELD BUCKET (INLINE DRAIN ON FILL BUCKET ONLY) <br /> H <br /> a <br /> BOOT AND CLAMPS 18" 42" THICKENED CONCRETE LV <br /> MINI HYDROSTATIC P. SLAB (TYP.) V <br /> SUMP SENSOR Z <br /> a (TAPE z <br /> U <br /> DEPTH 6" g <br /> q� Z MIN. 12" cn <br /> MAX.) o <br /> PEA GRAVEL BACKFILL (TYP.) W 04 <br /> a <br /> 6" WIDE DETECTABLE UNDERGROUND 0 N17 <br /> 2-IN-1 SENSOR BOX - o o - MARKING TAPE U rn <br /> JUNCTION BOX EMPIRE MAGNATEC #32-143 V in rn N <br /> 4" GALV. STEEL RISERS STAGE I VAPOR cc U <br /> SEE STATIC GROUNDING DETAILS RISER IS IN SAME PLANE AS TANK LEVEL Q LO co <br /> ON SHEET G.0.7.2 (TYP.) GAUGE IN THIS VIEW N z 0 <br /> #4 STRANDED BARE CU <br /> GROUND WIRE TO OTHER CONTRACTOR TO INSTALL CLEVIS <br /> TANKS (TYP.) AND COTTER PIN <br /> #4 STRANDED BARE CU TANK GAUGE ADAPTER <br /> m <br /> GROUND WIRE TO II & CAP VEEDER ROOT .1 GPH MAGNOSTRICTIVE U <br /> GROUND ROD (TYP.) PROBE TANK LEVEL PROBE W/ TLS CAP <br /> 1" FRP BONDED ENTRY FITTING & RING. OVERFILL ALARM SET © 90% <br /> (TYP.) z CAPACITY. USE 2" FLOAT IN INSTALL KIT <br /> 1" MONITORING CONDUIT <br /> (ROUTED TO INTERSTITIAL) 00 <br /> (ROBROY THROUGH SUMP ONLY) <br /> 42" DOUBLE WALL POLYGON SUMP <br /> BODY (8) FLAT PANELS <br /> SUMP MONITOR LIQUID SENSOR <br /> MOUNTED IN HOLDER <br /> STRAIGHT DROP TUBE z <br /> 0 <br /> WITH FLAPPER (TYP.) in <br /> SUMP TEST PLUG (TYP.) <br /> A: SECTION VIEW - FILL SIDE SUMP <br /> SCALE: 3/4" = 1'-0" (DIESEL TANK) <br /> w <br /> J_ <br /> SUMP MONITORING LIQUID 8" ACCESS PORT <br /> SENSOR 8" 8" 00 <br /> VEEDER ROOT .1 GPH MAGNOSTRICTIVE Q <br /> _ CIO Cnn PROBE TANK LEVEL PROBE W/ TLS CAP <br /> & RING. OVERFILL ALARM SET © 90% <br /> W N <br /> CD <br /> J > CAPACITY. USE 2" FLOAT IN INSTALL KIT a z <br /> o a <br /> MANWAY JACK SCREW (TYP.) <br /> o Q <br /> z <br /> TANK <br /> 4" FILL ADAPTER AND CAP IN SPILL <br /> CONTAINMENT FILL BOX <br /> ALL MANHOLE ACCESS COVERS TO BELOW GRADE <br /> SHALL BE LIQUID TIGHT AND LOCKABLE <br /> 0 o0 ov0000 v v 0 OPW 42" DIA. SINGLE-PORT FILL SPILL <br /> CONTAINMENT ASSEMBLY W/ (1) 5 GALLON <br /> SPILL BUCKET AND ADJUSTABLE FLARED <br /> SKIRTL� <br /> DIAMOND PLATE 42" DIA. BRINE MONITORED DOUBLE WALL <br /> CONTAINMENT SUMP (TYP.) <br /> NOTE: <br /> NOTES <br /> CONNECTION TO STAGE II VAPOR RECOVERY ��- <br /> NOT REQUIRED ON DIESEL TANK. SLOPE CONCRETE AWAY FROM ALL MANHOLES 1" RISE OVER 12" RUN <br /> B: PLAN VIEW - FILL SIDE SUMP <br /> FIBER REINFORCEMENT TO BE USED. PRE-MIX UNIFORMLY THROUGHOUT CONCRETE. <br /> SCALE: 3/4" = 1'-0" (DIESEL TANK) <br /> REINFORCING BARS TO BE NO LESS THAN 2" AND NO MORE THAN 4" FROM SURFACE. <br /> REINFORCE CONCRETE SLAB AROUND MANHOLE WITH 4-#3 REBAR 60" IN LENGTH. <br /> 33" O.D. (SINGLE FILL) PLACE REBAR 6" FROM SIDES OF BOX. <br /> ONE 1" STANDARD MONITORING HOMERUN CONDUIT TO EACH TANK. FOR STANDARD <br /> MONITORING DEVICES, LOOP CONTAINMENT SUMP SENSORS, PLLD, VAC SENSORS & TANK <br /> GAUGE TO TANK INTERSTITIAL SENSOR LOCATION AND HOMERUN TO BLDG. PROVIDE <br /> SEAL-OFFS IN BUILDING & PRIOR TO LEAVING HAZARDOUS AREA. ROUTE TO INTRINSICALLY ^ <br /> SAFE TROUGH IN BUILDING. CONDUITS SHALL CONTAIN ONLY LOW VOLTAGE WIRING FOR 11 <br /> o SENSORS. ALL CONDUIT PENETRATIONS MUST BE MADE WITH ROBROY PVC COATED <br /> CD Cn CONDUIT ONLY. <br /> o z o t' 01-1 <br /> bi <br /> FPEA GRAVEL BACKFILL. ALL SUBSTITUTES MUST BE APPROVED BY MANUFACTURER AND <br /> SLIP ON RISER 42" I.D. m N OWNER'S FIELD REPRESENTATIVE. z Q <br /> FIELD SEALED JOINT. DW POLYGON BODY a :!5PIPING SHALL BE LAID AND CONTINUOUSLY SUPPORTED ON A 6" COMPACTED PEA ® (__5 J <br /> (ADHESIVE SUPPLIED > L� J <br /> a GRAVEL BEDDING. PIPING SHALL NOT BE SUPPORTED BY BLOCKS, PLANKS, OR OTHER W <br /> W/ KIT) DEBRIS. ~ <br /> cf) <br /> ALL ENTRIES TO BE PERPENDICULAR TO CONTAINMENT SUMP. OFFLINE INSTALLATION <br /> 3/8 X 1/4 SS NOT PERMITTED. <br /> BUSHING REAM ALL RISERS FOR FULL PIPE BORE IF REQUIRED. w <br /> INSTALLED AT Cl— ^ <br /> � Q v J <br /> FACTORY INSTALL TANK ID MARKERS IN THE SPILL CONTAINMENT MANHOLES. COVERS SHALL BE Ln w <br /> PRIMED AND PAINTED ACCORDING TO SPECIFICATIONS. 0--) z _ <br /> FACTORY N SECONDARY CONTAINMENT IS REQUIRED FOR ALL VENT AND STAGE II VAPOR RECOVERY C) 0 Q <br /> PIPING. <br /> LAY-UP DW COLLAR <br /> BONDED TO IF COAT ALL BURIED GALVANIZED STEEL WITH COAL TAR EPDXY.TANK consultant job# <br /> LAYOUT TANKS & STAGE II VAPOR RECOVERY PIPING SUCH THAT THE STAGE II PIPING <br /> — _ DRAINS & ENTERS INTO REGULAR UNLEADED TANK FIRST W/ 3" CONNECTIONS, AND master release date <br /> JOINT DETAILS — — 2 CONTINUES 3" TO OTHER TANKS. <br /> CONCRETE SHALL BE THICKENED AT THE THE FILL SUMPS DOWN TO BELOW THE TOP project master <br /> OCONTRACTOR TO ADDITIONALLY GLASS WRAP & LAMINATE AT CONNECTION FOLLOWING CURING OF 42" DIA. POLYGON SUMP BODY OF CONTAINMENT OF THE DOUBLE WALL SUMP AS REQUIRED. DIMENSION OF SLAB exe date drawn by <br /> ADHESIVE. SPECIFIC ATTENTION MUST BE GIVEN TO SURFACE PREP AS TESTING REQUIREMENTS (8) 17 3/8" FLAT PANELS THICKNESS VARIES WITH SITE CONDITIONS. <br /> WILL DETECT THE SMALLEST OF FLAWS. ALL MATERIALS MUST BE COMPATIBLE WITH GASOLINE, <br /> GASOLINE WITH 15% MTBE (METHYL TERTIARY-BUTYL ETHER), OR GASOLINE WITH 10% ETCH 1/4" DRAIN/TEST BUSHING. CROSSING FLEX CONNECTORS MUST MAINTAIN A MINIMUM OF 2 INCH CLEARANCE OR <br /> (ETHANOL). FIBERGLASS AND RESIN MUST EXTEND 1/2" BEYOND COVERAGE OF ADHESIVE. FACTORY INSTALLED THE USE OF AN ANTI CHAFING DEVICE MUST BE INSTALLED. NOTE: CONTRACTOR TO USE ADDITIONAL <br /> NOTE: GALVANIZED FITTINGS AS REQUIRED TO Facility/Project <br /> OTHE STRAP CHANNEL IF PRESENT ON THE FILL SIDE SUMP DOES NOT "COMMUNICATE" WITH CONTRACTOR SHALL BE HELD RESPONSIBLE MINIMIZE BENDS IN FLEXIBLE CONNECTORS <br /> 2 <br /> THE INSIDE OF THE SUMP. CONTRACTOR TO BE SURE TO LEAVE UNOBSTRUCTED PATH FOR FOR PROPER INSTALLATION & PREPARATION <br /> STRAP TO PENETRATE INTO THE CHANNEL SO THAT TANKS MAY BE PROPERLY ANCHORED. PER MANUFACTURERS INSTRUCTIONS AND sheet name <br /> SHALL REINSTALL SUMPS IF HYDROSTATIC <br /> F: TYPICAL DOUBLE WALL FILL SUMP TESTING SHOWS LEAKING IN THIS AREA OF M .5.3. 1 8 <br /> SCALE: 3/4" = 1'-0" THE SUMP. <br />