Laserfiche WebLink
DISPENSER 28.7 26.9 AGCDC.COM <br /> 3'-77/16" SKIN 15.1 15.1 31.8 23.8 <br /> 3'-7 Y4" INSIDE 1" N.P.T. VAPOR CABLE TO VAPOR PRESSURE Z ` <br /> 1 -1/2"N.P.T. INLET (3) 1'-5" 1'-5" RECOVERY OUTLET, <br /> JUNCTION BOX SENSOR <br /> (OPTIONAL) 2—WAY VAPOR FLOW <br /> CALIBRATION SENSOR I I W <br /> oQ Q o VALVE <br /> rn V <br /> 1" SHORT VAPOR SHEAR o Z <br /> VALVE Of <br /> NIPPLE ED <br /> w FUEL WHIP HOSE 0 <br /> 00 STABILIZER z C) <br /> ASSEMBLY ' ' UJ <br /> � I Z <br /> 1/4" OD INREDUCE THREADS I z o FUEL HOSE BREAKAWAY 0 <br /> COPPER TUBING. FROM 1-1/2 TO �I r, <br /> AVOID ANY 1/4" W/ DOUBLE NOTE: J p F N <br /> O O TRAPS! (BY TAP BUSHINGS) CAT 5 CABLE SHALL BE INSTALLED w W :? <br /> FOR BOTH ENHANCED OR STANDARD z 0 W N <br /> CONTRACTOR w m LO <br /> PRODUCT 1 REGULAR VAPOR RETURN ELECTRONICS MENT o J -— M <br /> # (REGULAR) 5/8" x 2" SLOTS FOR ANCHOR BACK TO TANKS w V rn `�' <br /> PRODUCT #2 (PREMIUM) 10�2 1 —1 BOLTS, 6 SPACES CONTAIN SUMP <br /> I z z I Q v <br /> JUNCTION BOX 12" X 12" STEEL Of U N c <br /> SIDE "A" CANOPY COLUMN M O <br /> VST PHASE II W/ VEEDER-ROOT ISD <br /> z <br /> SCALE: NTS BALANCE PHASE II SYSTEM 4" PVC CANOPY N z 0- <br /> A-A DISPENSER MOUNTING DIAGRAM DRAIN EACH COLUMN WAYNE 3+0 BLENDER <br /> SCALE: 1"=1'-0" <br /> °°°° <br /> (1) 1" CONDUIT TO I °°°°°° <br /> m U <br /> EACH COLUMN <br /> — — o0 <br /> -H SAFETY NOTE: a' <br /> D M WHEN DISPENSERS ARE INSTALLED I NOZZLE (TYP.) <br /> DISPENSER SUMP FRAME / I \ 00 AS SHOWN ON THIS DRAWING, THE <br /> (ADJUSTABLE HEIGHT) REQUIREMENTS OF NFPA 30A 6.3.9 <br /> / \= A AND 6.3.9.1 REGARDING SHEAR <br /> SECTIONS ARE FULLY MET. 19I I FUEL HOSE — <br /> w ❑ ❑ <br /> o O ■ - <br /> o 0 0 <br /> w a <br /> U O <br /> L . 0 I <br /> J I I z <br /> o <br /> O SEE BOLLARD !2c) <br /> Q DETAIL ON Ld <br /> Q SHEET G.0.5 <br /> RUN CONDUITS THROUGH D I <br /> OFFSET CAVITY IN <br /> I Cn o <br /> DISPENSER SUMP FRAME I1 4".5UJ <br /> .00 <br /> NOTE: CONDUITS SHALL NOT <br /> PENETRATE SUMP. ROUTE EXPANSION JOINT 4,000 PSI <br /> THROUGH OFFSET FRAME (TYP.) SEE CONCRETE i <br /> CAVITY. DO NOT CUT SIDE CONCRETE DETAILS CONCRETE MIX m <br /> PANELS OF DISPENSER NOTE: CONCRETE SLAB I v SHEET M.5.3.27 m <br /> B-B DISPENSER CONTAINMENT SUMP PLAN VIEW 1. ONLY (1) VAPOR PRESSURE " FOR DETAIL I " I v Q <br /> SCALE: 1" = 1'-0" SENSING DEVICE REQUIRED C° a <br /> PER SITE. SENSOR SHALL BE ° a N <br /> MOUNTED AT ONLY (1) ^ ° ° a a v a N <br /> DISPENSER LOCATED CLOSEST a CO J ° a c° II a v ° Z <br /> 2—IN-1 SENSOR TO TANKS. ° a v v I I 4 ° a a <br /> BOX I a ° o <br /> SUMP SENSOR 2. CONTRACTOR SHALL PITCH ALL I I I 4 Z Q <br /> J—BOX DISPENSER 1/4" TUBING AS REQUIRED TO J v <br /> DISPENSER SKIN ' ' J—BOX Of <br /> AVOID ANY LIQUID TRAPS � EXPANSION <br /> PRODUCT SHEAR D U OPTIONAL STORM DRAIN JOINT TYP. <br /> VALVE (TYP.) U D ROUTING, SEE CIVIL SITE SEE CONCRETE a <br /> ELBY CAPPED D 4 <br /> PLAN FOR ACTUAL DETAILS SHEET d ° <br /> ELBOW (TYP.) ,q I a = <br /> PIPING UNIONS � � � ROUTING AND I <br /> w CONTINUATION DETAIL <br /> 27 FOR Q <br /> BY WAYNE _ — z <br /> SEAL OFF (TYP.) I / � I DETAI L o <br /> VAPOR SHEAR VALVE \/�\/�\/�\/�\ \/�\/�\/�\/� / o <br /> z_ w <br /> e e m <br /> d <br /> d a 4 . <br /> d ^ <br /> ° ° Co I i U) <br /> e e ° e e ° I w <br /> Of <br /> 1" INTERCOM Id ° "' Ol 3 �8 <br /> CONDUIT <br /> BRINE RESERVOIR & <br /> „ ° , <br /> 1 POWER/DATA HYDROSTATIC SENSOR ° I I • ° ° e e • d° 4" <br /> ° n ° � e e • d DISPENSER CONTAINMENT° ° d *MINIMUM RECOMMENDED SUMP <br /> CONDUIT ATTACHED TO SUMP a ° ° • ° /\ ° a ° e <br /> 1 MONITORING J d • ° ° • J e d ° ° e DIMENSION. SEE NOTE BELOW <br /> 1-1/2"x18" FLEX D �° �° I� 1!= �• ° ° (TYPICAL) <br /> CONDUIT D e ° ° e e d ° � e ° ° ° IT I� COMPACTED OR NATIVE SOIL A <br /> CONNECTOR • e ° ° • d ° a e ° a e ° ° • d °• el e <br /> ° ° ° e d ° ° ° e d InI n O <br /> 2" INSIDE 3" FRP 3" INSIDE 4" FRP ° ° e ° ° ° e ° NOTE: L�J�L�I <br /> PRODUCT LINE VAPOR LINE cn ° d °• a e ° ° °J d °• a e ° IF REQUIRED BY LOCAL <br /> 3" D.W. FRP BONDED ENTRY FITTING ° °e � ° °e CODES, EXTEND CONCRETE <br /> L`' d UNDER BOLLARD BELOW THE <br /> W/ 4"x3" CONCENTRIC REDUCER W/ ° d <br /> e °d � d° G ° ° e ° ° • ° ° d � e °d � d ° ° e ° ° ° <br /> TEST PORT & 1/4" PLUG (TYP.) ° a e d e ° e e ° ° d a e d ° ° <br /> ° e d ° ° • ° • • FROST LINE. ® ,� W <br /> DOUBLE WALL UNDER d ° • d ° d ° • e d CD 7 <br /> SUMP SENSOR IN ° I L <br /> HOLDER DISPENSER I� (SEE STRUCTURAL) � � (SEE STRUCTURAL) PROJECTION OF ADA REQUIRED <br /> CONTAINMENT SUMP � FRONT ELEVATION <br /> C-C: FRONT VIEW SECTION DETAIL @ DISPENSER SUMP DISPENSER ON ISLAND INSTALLATION DETAILS SIDE ELEVATION NOTE: CANOPY FOOTINGS CAN BE VERY Q <br /> SCALE: 1 —1 —0 SCALE: 1 = 1'-0" LARGE AND CAN VARY IN SIZES. SEE <br /> STRUCTURAL DRAWINGS. <br /> ADA PLATFORM (NTS SEE BELOW) J <br /> NOTE: IF THERE IS NO ROOM TO INSTALL THE *MINIMUM RECOMMENDED _ <br /> VAPOR FLOW METER ABOVE THE SHEAR VALVE, DIMENSION. SEE NOTE BELOW <br /> IT IS ACCEPTABLE TO INSTALL FLOW METER "B" SIDE OF DISPENSER <br /> BELOW SHEAR VALVE PER LATEST EDITION OF 2'-6" 2'-6" 1 <br /> E.O. VR-202 ON HEALY SOLUTION & E.O. / C/-) w <br /> VR-204 ON VST SOLUTION. SEE MOST RECENT <br /> VEEDER ROOT INSTALLATION INSTRUCTIONS FOR 2—IN-1 SENSOR BOX I DISPENSER LINE OF CANOPY 1 Y4 SIDE "B" / L' <br /> ISD FLOW METERS I�� COLUMN / z Q <br /> U <br /> A WAYNE DISPENSER FRAME VAPOR FLOW SENSOR SUMP SENSOR J—BOX I I <br /> ELBY CAPPED ELBOW (TYP.) I I I BRINE RESERVOIR & � W W <br /> 1-1/2"x18" FLEX CONNECTOR PRODUCT SHEAR VALVE I I I 0 ) z � <br /> SEAL—OFF (TYP.) I I HYDROSTATIC SENSOR EXACT LOCATION 1J Q <br /> I ATTACHED TO SUMP 1 w <br /> VAPOR SHEAR VALVE I I O V, " SUBJECT TO AUTHORITYCD � O 7 <br /> RUN CONDUITS THROUGH I I I OPTIONAL STORM DRAIN z M w d ^ HAVING JURISDICTION. C 7 = Z <br /> ° a OFFSET IN DISPENSER I i DISPENSER JUNCTION ROUTING, SEE CIVIL SITE _IJ JIB of z <br /> � SEE BOLLARD DETAIL w <br /> BOX (TYP.) w o ON SHEET G.0.5 <br /> v a ILI— <br /> SUMP FRAME (TYP.), I I PLAN FOR ACTUAL ROUTING I z U Cn Q <br /> E!-- �I AND CONTINUATION w w I z w � �^ <br /> 3„ D.W. FRP BONDED ENTRY I U O Ln z V J <br /> FITTING W/ 4"x3" CONCENTRIC ° I —=_ 1 / o CD <br /> CD <br /> REDUCER W/ TEST PORT & '► SENSOR MOUNTING �\ ��� LINE OF FOUNDATION pQ O Q <br /> 1/4 PLUG (TYP.) SUMP SENSOR IN HANGER KIT (TYP.) BELOW. (SEE y <br /> HOLDER \ <br /> STRUCTURAL) <br /> 3" INSIDE 4" FRP � consultant job# <br /> RECOVERY LINE 1" DISPENSER \ bi <br /> SIDE "A" <br /> INTERCOM e \ master release date <br /> • TEST PORT AT UDC CONDUIT I <br /> project master <br /> 3'-7y2" exe date drawn by <br /> 1" DISPENSER <br /> • —� <br /> 2" INSIDE 3 FRP 0 POWER & DATA—_ DISPENSER ISLAND „ <br /> PR DUCT LINE C 04�04�04�04�, CONDUIT * (TYP.) 5 —0 <br /> ° °� 1" MONITORING SUMP MONITOR NOTE: THESE DIMENSIONS REPRESENT MINIMUM RECOMMENDED Facility/Project <br /> Pro'ect <br /> _ LIQUID SENSOR OFFSET DIMENSIONS TO PROVIDE DESIRED CLEARANCE OF THE y� J <br /> 2" FRP ELBOW WITH III — I COMPACTED OR NATIVE CONDUIT DISPENSER VALENCE FROM THE COLUMN AND ARE BASED ON A <br /> PEA GRAVEL 2" FRP X 1-1/2" —�i' SOIL (TYPICAL) MAXIMUM 12"X12" NON—CLADDED COLUMN DESIGN. WHERE ADA REQUIRES 48"x30" MIN. AREA IN FRONT OF <br /> FNPT BUSHING DOUBLE WALL UNDER DISPENSER ARCHITECTURAL COLUMN WRAPPING IS REQUIRED THE 1'-4 1/4" BOTH SIDES OF MPD, SLOPE NOT TO EXCEED 2%.� <br /> CONTAINMENT SUMP <br /> MINIMUM FACE TO FACE DIMENSION SHALL TAKE PRECEDENCE. THERE SHALL BE A 10" MIN DISTANCE FROM THE sheet name <br /> EDGE OF PLATFORM TO DISPENSER FACE FOR SID M .5.3 .23 <br /> D-D - SIDE VIEW SECTION @ DISPENSER SUMP DISPENSER CONTAINMENT SUMP CONDUIT ROUTING DETAIL DISPENSER ON ISLAND PLAN VIEW REACH <br /> SCALE: 1"=1'-0" SCALE: NONE SCALE: 1"=1'-0" /1///////1//////L/ <br /> SUMP SENSOR IN <br />