d <br />GENERAL NOTES: <br />PROVIDE AND INSTALL ANGLE STOP UNDER THE SINKS AT <br />EASILY ACCESSIBLE LOCATION. <br />PROVIDE AND INSTALL ACCESS PANEL FOR ISOLATION VALVES <br />AND WATER HAMMER ARRESTOR, <br />PLUMBING CONTRACTOR SHALL AVOID LOCATING OR <br />MOUNTING OVERHEAD PLUMBING LINES DIRECTLY ABOVE THE <br />ELECTRICAL PANELS OR EQUIPMENT. <br />OVERHEAD PLUMBING LINES SHALL BE AT LEAST 6 AWAY <br />MINIMUM FROM ROOFTOP UNITS SUPPLY AND RETURN <br />GRILLEIDUCT ROOF PENETRATIONS. INSTALL OVERHEAD PIPING <br />AS FAR AWAY AS POSSIBLE TO AVOID MAIN DUCT ROOF <br />PENETRATIONS, <br />PLUMBER TO COORDINATE WITH OTHER TRADES PRIOR OF <br />INSTALLATION OF PIPING ABOVE THE CEILING. PLUMBER TO <br />REROUTE PIPING AS NEEDED TO AVOID EXISTING HVAC DUCTS <br />AND ELECTRICAL COMPONENTS, <br />GENERAL CONTRACTOR TO REMOVE ALL UNUSED GAS PIPING <br />AND BE PROPERLY DISPOSED OF. <br />o._,.... ___ <br />PLUMBING KEY NOTES: OX <br />1. VCW LINE IN ATTIC SPACE TO NEW REMODELED KITCHEN AREA. <br />SEE SHEET P2.2 FOR CONTINUATION. <br />2. VHW (1407) & 314"HWR LINES FROM/TO NEW (3) TANKLESS WATER <br />HEATERS IN THE ATTIC SPACE. SEE SHEET P2.2 FOR <br />CONTINUATION. Al <br />3. VCW & VHW (140- F) DOWN IN WALL TO BELOW GROUND. <br />4. <br />SINK. PROVIDE 112" CW & HW CONNECTIONS FOR EACH FAUCET. <br />5. 112" CW DOWN TO VALVED TRAP PRIMER. PROVIDE AND INSTALL <br />ACCESS PANEL. <br />6. 314" CW & 314" HW (140° F) DOWN IN WALL TO DISHWASHER. COLD <br />WATER USE FOR DRAIN TEMPERING VALVE DTV -1 . <br />7. 1/2"CW & 112"HW (140° F) DOWN IN WALL TO HAND SINK. PROVIDE <br />POINT OF USE THERMOSTATIC MIXING VALVE (MV -1) AT <br />ACCESSIBLE LOCATION. SET OUTLET TEMPERATURE TO 120'F. <br />8. NOT USED. <br />1 <br />9. NOT USED. <br />10. 314" GAS TO FIXTURE. <br />11, CONNECT TO EXISTING 314" MEDIUM (2 PSI) PRESSURE PROPANE <br />GAS. PROVIDE AND INSTALL GAS PRESSURE REGULATOR GPR-2 <br />WITH OUTLET PRESSURE OF 11"W.C. MINIMUM. PROVIDE WITH <br />VENTLESS AND OVERPRESSURE PROTECTION DEVICE. VERIFY IN <br />FIELD EXACT SIZE, LOCATION, PRESSURE AND DISTANCE FROM <br />PROPANE TANK AND 2ND STAGE GAS PRESSURE REGULATOR <br />GPR-1. <br />12. NOT USED. <br />13. NOT USED. <br />14. FIRE -SUPPRESSION GAS SHUT-OFF ANSUL VALVE. INSTALL AT <br />ACCESSIBLE LOCATION. <br />15. GAS DOWN IN WALL AND ROUTE THRU WALL AS SHOWN. <br />16. NOT USED. <br />17. NOT USED. <br />18, NOT USED. <br />19. 112"CW & 112"HW (140° F) DOWN IN WALL. <br />20. 112"CW & 112"HW (140° F) TO PASS THROUGH BEVERAGE STATION <br />FAUCET.PROVIDE POINT OF USE THERMOSTATIC MIXING VALVE <br />(MV -1) AT ACCESSIBLE LOCATION. SET OUTLET TEMPERATURE TO <br />120'F <br />21. 314"CW & 3/4"HW (140° F) THROUGH COUNTER TO 3 TUB BAR SINK. <br />22. 314"CW & 3/4'HW (140° F) FROM BELOW BELOW GROUND TO PREP <br />SINK FAUCET. <br />23. 112"CW & 112"HW (140° F) THROUGH COUNTER TO HAND SINK. <br />PROVIDE POINT OF USE THERMOSTATIC MIXING VALVE (MV -1) AT <br />ACCESSIBLE LOCATION. SET OUTLET TEMPERATURE TO 1200F. <br />24. 1/2"CW TO MAKEUP AIR UNIT. SEE SHEET P2.2 FOR CONTINUATION. <br />25. 314"CW DOWN IN WALL TO ICE MACHINE THROUGH WATER FILTER <br />(ITEM #64) <br />NOTES SCALE I <br />,/4„=1,-0„ <br />i <br />I PLUMBING DOMESTIC WATER AND GAS FLOOR PLAN SCALE 1 I KEY PLAN SCALE I <br />i/4"=1'-0" 1 1116"=1'-0" L <br />N <br />ACTS <br />ENGINEERING <br />3371 Olcott Street <br />Santa Clara, CA 95054 <br />ph: (408) 522-5255 <br />fx: (408) 522-5260 <br />info@acies.net <br />Copyright © 2020 <br />OQROFESS/pyq <br />HuFyFyc' <br />No 39192 <br />Ex 1 <br />lF OF CA01 Jf <br />O <br />H N N <br />CN <br />LLJ <br />:2 Z LO <br />LLI_ 0) <br />U <br />LL a o0 <br />Z O <br />Z <br />LdH <br />REVISIONS: <br />A04.14.20 <br />JOB NO.: 19362 <br />ISSUE: PERMIT <br />DATE: 02.26.20 <br />FILENAME: <br />UJI <br />Q Z <br />J <br />C/) 0 <br />� <br />O <br />O LL <br />0 Q <br />CD 0 <br />z <br />m 0 z <br />� IQ <br />J <br />SHEET NO.: <br />P201 <br />d <br />PLOT DATE: <br />