1 <br />aar� <br />GENERAL NOTES <br />PLUMBING CONTRACTOR TO PERFORM SEWER SCOPE AND <br />HYDROJET THE EXISTING SANITARY SEWER SYSTEM. PROVIDE A <br />COMPLETE REPORT TO THE OWNER AND ARCHITECT AFTER <br />SCOPING THE SEWER SYSTEM. <br />OVERHEAD PLUMBING LINES SHALL BE AT LEAST 5' AWAY MINIMUM <br />FROM ROOFTOP UNIT'S SUPPLY AND RETURN GRILLE/DUCT ROOF <br />PENETRATIONS, INSTALL OVERHEAD PIPING AS FAR AWAY AS <br />POSSIBLE TO AVOID MAIN DUCT ROOF PENETRATIONS. <br />ALL UNUSED FLOOR DRAINS OR FLOOR SINKS SHALL BE REMOVED <br />AND HARD -CAP BELOW FLOOR. <br />PLUMBING CONTRACTOR TO REROUTE AND EXTEND AS NEEDED <br />THE EXISTING CONDENSATE DRAIN PIPING BELOW THE ROOF DECK <br />TO INDIRECTLY DISCHARGE INTO AN APPROVED RECEPTOR OR <br />MOP SINK. <br />I I [ <br />PLUMBING KEY NOTES: OX <br />1. CONNECT TO EXISTING WASTE LINE BELOW FLOOR. VERIFY IN <br />FIELD EXACT LOCATION AND SIZE PRIOR OF ACTUAL WORK. UPSIZE <br />IF NEEDED, <br />2. 2"SS DOWN AND 2"V UP FOR HAND SINK. <br />3. 3"SS DOWN AND 2"V UP FOR FLOOR DRAIN / FLOOR SINK. Q <br />4. RUN FULL LINE SIZE COPPER INDIRECT DRAIN FROM DRAFT BEER <br />DISPENSER AND DISCHARGE INTO FLOOR SINK VIA 2" AIR GAP. <br />5. RUN FULL LINE SIZE COPPER INDIRECT DRAIN FROM PREP SINK <br />AND DISCHARGE INTO FLOOR SINK VIA 2" AIR GAP. <br />6. RUN FULL LINE SIZE COPPER INDIRECT DRAIN FROM THREE <br />COMPARTMENT SINK BEHIND DISHWASHER AND DISCHARGE TO <br />GREASE TRAP GT -1. <br />7, RUN FULL LINE SIZE COPPER INDIRECT DRAIN FROM DISHWASHER <br />AND DISCHARGE INTO FLOOR SINK VIA 2" AIR GAP, <br />8. ISLAND SINK DRAIN AND VENT. SEE DETAIL #7/P4.1. <br />9. 3" SS FROM SIDE OUTLET OF GREASE TRAP RUN BEHIND <br />DISHWAHER AND DISCHARGE TO FLOOR SINK. PLUMBER TO <br />LOCATE GT -1 AT EASILY ACCESSIBLE LOCATION BELOW CLEAN <br />DISHTABLE FOR SERVICE/CLEANING. <br />10. CONNECT TO EXISTING VENT LINE ABOVE CEILING. VERIFY IN FIELD <br />EXACT LOCATION AND SIZE PRIOR OF ACTUAL WORK. RE-ROUTE IF <br />NEEDED. UPSIZE IF NEEDED. <br />11. 2" VENT UP. <br />12. FULL LINE SIZE DRAIN FOR CONDENSATE FROM EXHAUST PIPE <br />DOWN IN WALL TO INDIRECTLY DISCHARGE INTO (E) MOP SINK <br />THROUGH 2" AIR GAP. SEE SHEET P2.2 FOR CONTINUATION. <br />13. FULL LINE SIZE DRAIN FROM TANKLESS WATER HEATERS DOWN IN <br />WALL TO INDIRECTLY DISCHARGE INTO (E) MOP SINK THROUGH 2" <br />AIR GAP. SEE SHEET P2.2 FOR CONTINUATION. <br />14, 3/4"ID WITH MINIMUM SLOPE OF 118" PER FOOT IN THE ATTIC SPACE, <br />RUN DOWN IN WALL AND DISCHARGE TO FLOOR SINK THRU 2' AIR <br />GAP. SEE SHEET P2.2 FOR CONTINUATION. <br />15. 314"CD WITH MINIMUM SLOPE OF 118" PER FOOT IN ATTIC SPACE, <br />RUN DOWN IN WALL AND DISCHARGE TO FLOOR SINK THRU 2" AIR <br />GAP. SEE SHEET P2.2 FOR CONTINUATION. <br />16. 3' VENT UP FROM BELOW GROUND. 1Q <br />17. RUN FULL LINE SIZE COPPER INDIRECT DRAIN FROM BEVERAGE <br />STATION AND SEPARATE FULL LINE SIZE COPPER INDIRECT DRAIN <br />FROM SINK BOWLS AND DISCHARGE INTO FLOOR SINK VIA 2" AIR <br />GAP. <br />18. RUN FULL LINE SIZE COPPER INDIRECT DRAIN FROM ICE BIN AND <br />DISCHARGE INTO FLOOR SINK VIA 2" AIR GAP. <br />19. RUN FULL LINE SIZE COPPER INDIRECT DRAIN FROM GLASSWARE <br />DRAIN STATION AND DISCHARGE INTO FLOOR SINK VIA 2" AIR GAP.Q <br />20, RUN FULL LINE SIZE COPPER INDIRECT DRAIN FROM 3 TUB BAR <br />SINK AND DISCHARGE INTO FLOOR SINK VIA 2' AIR GAP. <br />21, VENT TAKE -OFF BELOW GROUND. SEE DETAIL #6/P4.1 <br />22. EXISTING FLOOR SINK AND ASSOCIATED PLUMBING LINES TO BE <br />DEMOLISHED. HARD -CAP PLUMBING LINE BELOW FLOOR OR <br />BEHIND THE WALL. <br />23. RUN FULL LINE SIZE COPPER INDIRECT DRAIN FROM ICE MACHINE <br />W/BIN AND DISCHARGE INTO FLOOR SINK VIA 2" AIR GAP. <br />24. REMOVE OLD FLOOR SINK AND DISPOSED OF. <br />25, REMOVE OLD HAND SINK AND DISPOSED OF. <br />I <br />NOTESI SCALE 3 ' <br />1/4"=1'-0" <br />I PLUMBING SANITARY SEWER AND VENT FLOOR PLAN SCALE 1 I KEY PLAN SCALE 2 I <br />114"=1'-0" 1/16"=1'-0" <br />i <br />ACIES <br />ENGINEERING <br />3371 Olcott Street <br />Santa Clara, CA 95054 <br />ph: (408) 522-5255 <br />fx: (408) 522-5260 <br />info@acies.net <br />Copyright © 2020 <br />QRO F ESS/ONq'. <br />HV�e <br />_• y Z <br />W No 39192 <br />= Ex 1 <br />P� �P <br />,F OF CALk <br />J <br />0 <br />I— N N <br />z t <br />LSI CN <br />M Z Ln <br />L _ 0) <br />Of 3: U <br />a0 E <br />� <br />z 't O <br />H <br />z <br />Ld <br />H / <br />REVISIONS: <br />A04.14.20 <br />2 05.01.20 <br />JOB NO.: 19362 <br />ISSUE: PERMIT <br />PA <br />TE:: 02.28.20 <br />FILENAME: <br />w <br />Lu <br />�z <br />Lu <br />cf) <br />O <br />O <br />Q LIL. <br />U) ~ <br />z <br />(D w <br />z> <br />mo <br />�z <br />�Q <br />_j <br />d <br />SHEET NO.: <br />P200 <br />PLOT DATE: <br />