Laserfiche WebLink
IMPORTANT: The instructions below for the 71 SO Upper Tube Length =C+(A) <br /> Overfill Prevention Valve are written for the initial <br /> stage shutoff at 95%,but can be adjusted to shutoff For testable models only,ending in"T": <br /> at any desired tank capacity. Please contact the Au- Upper Tube Length=C+ (A)- 1-1/2" <br /> thority Having Jurisdiction (AHJ)and review local, <br /> state,and national codes to determine the regulato- YES Upper tube length is 6-1/2"plus the riser pipe <br /> ry requirements governing shut-off capacity in your measurement(A). <br /> region,as well as take into account other considera- <br /> tions such as extreme tank tilt. In all cases,the up- Upper Tube Length =6-1/2"+(A) <br /> per tube must protrude into the tank at least 61/2" <br /> to ensure that the valve can shut off flow into the For testable models only,ending in"T": <br /> tank completely before the top of the tank is wetted Upper Tube Length=6-1/2"+(A) - 1-1/2" <br /> consistent with EPA requirements 40 CFR 280.20(c) <br /> (1) (ii)(C). NOTE: You must find the actual tank capacity num- <br /> HOW TO LOCATE THE POSITION OF THE 71 SO AT ber that correlates to the 6-1/2"+(A) depth for the <br /> 95%TANK CAPACITY station records. This number may also be used for <br /> (Shut-off points can be adjusted to any capacity to the purposes of calibrating an electronic tank level <br /> comply with AHJ Requirements) system. <br /> The length of the upper tube and the placement of the elan Mount A anway Mtsunt —Tapernrasure <br /> Tape measure <br /> 71 SO valve body determine the shut-off point. Follow- <br /> ing the standard instructions for the OPW 71 SO will pro- } } } �- <br /> C,onsuhtank 's <br /> vide for initial shutoff at 95%. In all cases,the upper _ m���tarturer _- ' (A) A <br /> farhelghi ofY .i To Tank To Tank <br /> tube length must be a minimum of 6-1/2"plus the the manw" Top(.°.) aattom <br /> length of the riser pipe. All length measurements are in ! � (5"typical) ! ! <br /> S )A) <br /> inches. TO Tank 161 <br /> TopJI.D.) To Tank <br /> NOTE: When installing 71 SO and the actual measured + eom <br /> tank diameter is smaller than the tank diameter as des- <br /> ignated on the tank calibration chart, use the smaller <br /> dimension in determining your 95%capacity from. Figure 1 <br /> INSTRUCTIONS <br /> 1) Find tank capacity(in gallons)from tank calibration <br /> chart provided by tank manufacturer. EXAMPLE <br /> 2) Calculate 95%of capacity <br /> 3) Locate the 95%volume number on the tank calibra- 1) For an Owens-Corning Model G-3 Fiberglass®Tank <br /> tion chart. Calibration Chart: <br /> 4) Find the dipstick number (X)which corresponds to Tank Capacity- 10,000 gal., nominal 9,403 gal. <br /> the 95%tank volume. And,find the dipstick num- NOTE: Use actual capacity only <br /> ber(Y)which corresponds to the 100%volume. 2) 95%of actual tank capacity=0.95 x 9403 gal._ <br /> 5) Subtract the dipstick number(X)from the tank di- 8933 gal. <br /> ameter(Y)to find the upper tube reference number 3) The closest number which is less than 8933 gal.Is <br /> (Z). 8910 gal.Choosing the closest number less than <br /> (Y)-(X)=(Z) 95%of actual capacity ensures that the initial <br /> shutoff will occur when the tank is no more than <br /> 6) Subtract 2"from (Z)to find the upper tube depth 95%full. <br /> (Z)-2"=C 4) The calibration chart reading of 8910 gal.corre- <br /> 7) Is C less than 6-1/2"? sponds to a dipstick measurement of 82". <br /> NO Upper tube length is C plus the distance from <br /> the top of the Face Seal Adaptor installed on <br /> the riser pipe to the inside,top lip of the storage <br /> tank(A). <br /> 4 <br />